background image

H E A D I N G

1.

Save the carton and packing material even if the equipment has

arrived in good condition. Should you ever need to ship the unit, 

use only the original factory packing.

2.  Read all documentation before operating your equipment. 

Retain all documentation for future reference.

3. Follow all instructions printed on unit chassis for proper operation.

4. Do not spill water or other liquids into or on the unit, or operate the

unit while standing in liquid.

5. Make sure power outlets conform to the power requirements listed 

on the back of the unit.

6.  Do not use the unit if the electrical power cord is frayed or broken.

The power supply cords should be routed so that they are not likely 

to be walked on or pinched by items placed upon or against them,

paying particular attention to cords and plugs, convenience

receptacles, and the point where they exit from the appliance.

7.  Always operate the unit with the AC ground wire connected to the

electrical system ground. Precautions should be taken so that the

means of grounding of a piece of equipment is not defeated.

8.  Mains voltage must be correct and the same as that printed on the

rear of the unit. Damage caused by connection to improper AC

voltage is not covered by any warranty.

9.  Have gain controls on amplifiers turned down during power-up to

prevent speaker damage if there are high signal levels at the

inputs.

10. Power down & disconnect units from mains voltage before making

connections.

11. Never hold a power switch in the “ON” position if it won’t stay

there itself!

12. Do not use the unit near stoves, heat registers, radiators, or other 

heat producing devices

13. Do not block fan intake or exhaust ports. Do not operate 

equipment on a surface or in an environment which may impede

the normal flow of air around the unit, such as a bed, rug,

weathersheet, carpet, or completely enclosed rack. If the unit 

is used in an extremely dusty or smoky environment, the unit 

should be periodically “blown free” of foreign matter. 

14. Do not remove the cover. Removing the cover will expose you to

potentially dangerous voltages. There are no user serviceable

parts inside.

15. Do not drive the inputs with a signal level greater than that

required to drive equipment to full output.

16. Do not connect the inputs / outputs of amplifiers or consoles to

any other voltage source, such as a battery, mains source, or

power supply, regardless of whether the amplifier or console is

turned on or off.

17. Do not run the output of any amplifier channel back into another

channel’s input. Do not parallel- or series-connect an amplifier 

output with any other amplifier output.

Australian Monitor Inc is not responsible for damage to

loudspeakers for any reason.

18. Do not ground any red (“hot”) terminal. Never connect a “hot” 

(red) output to ground or to another “hot” (red) output!

19. Non-use periods. The power cord of equipment should be unplugged

from  the outlet when left unused for a  long  period of time.

20. Service Information Equipment should be serviced by qualified

service personnel when:

A.

The power supply cord or the plug has been damaged.

B.

Objects have fallen, or liquid has been spilled into the

equipment

C.

The equipment has been exposed to rain

D.

The equipment does not appear to operate normally, 

or exhibits a marked change in performance

E.

The equipment has been dropped, or the enclosure damaged. 

I M P O RTA N T   S A F E T Y   I N F O R M AT I O N  

THIS SAFETY INFORMATION IS OF A GENERAL NATURE AND MAY BE SUPERSEDED BY INSTRUCTIONS CONTAINED WITHIN THIS MANUAL

Содержание DIGIPAGE DP16M

Страница 1: ...tralian Monitor 1 Clyde Street Silverwater NSW 2128 Australia 61 2 9647 1411 www australianmonitor com au SERVICE INFORMATION DIGIPAGE DP8M DP16M PAGING STATION CONTENTS OPERATION MANUAL SCHEMATIC DIAGRAMS ...

Страница 2: ...PAGING STATION INSTALLATION AND OPERATION MANUAL DigiPage8M DigiPage16M ...

Страница 3: ...k fan intake or exhaust ports Do not operate equipment on a surface or in an environment which may impede the normal flow of air around the unit such as a bed rug weathersheet carpet or completely enclosed rack If the unit is used in an extremely dusty or smoky environment the unit should be periodically blown free of foreign matter 14 Do not remove the cover Removing the cover will expose you to ...

Страница 4: ...T 5 cable and as with all Australian Monitor installation products the Paging Station provides an elegant solution at a contractor friendly price INTRODUCTION 3 CONTROLS 4 INSTALLATION SETUP 5 NOTES 6 This symbol is intended to alert the user to the presence of uninsulated dangerous voltage within the product s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to...

Страница 5: ...t does NOT clear the current zone selection configuration so the paging station will return to its previous state selected zones once the ALL PAGE button is released ZONE PAGE This button pages to the current zone selection configuration as indicated by the ZONE select LEDs The zones being paged have their program sources muted and the microphone becomes active If no zones are selected the system ...

Страница 6: ...trol on the base of the DigiPageM This ships set to minimum and may be adjusted to suit Increasing this control too far may cause the paging station to distort if loud or close speech levels are encountered TERMINATING In an RS485 network of which the DigiPage is part of it is important to terminate the last device in the network CAT5 RUN Two jumpers are provided for the data transmission and the ...

Страница 7: ...PAGE 6 DIGIPAGE8M DIGIPAGE16M INSTALLATION OPERATION MANUAL NOTES ...

Страница 8: ...Email sa audiotelex com au PERTH WA SALES 299 Fitzgerald Street West Perth WA 6005 PO Box 404 North Perth WA 6906 Phone 08 9228 4222 Fax 08 9228 4233 Email wa audiotelex com au AUCKLAND NZ SALES Unit B 11 Piermark Drive Albany 1331 New Zealand PO Box 512 Albany 1331 Phone 09 415 9426 Fax 09 415 9864 Email sales audiotelex co nz AUSTRALIA AND NEW ZEALAND www australianmonitor com au INTERNATIONAL S...

Страница 9: ... 100K R19 2k2 R18 10K R17 10K R1 100K R2 47K R3 10K R4 5K6 R5 470R R6 100K R7 47K R8 10K R9 5K6 R10 470R R11 2K V1 BC546 V2 BC546 C1 1u C2 1u C3 1n C4 4u7 C5 22u C6 1n V3 BC546 R12 100R R13 2k2 5 6 4 IC1B 4093 8 9 10 IC1C 4093 V4 BC546 V5 BC546 V6 BC546 V7 BC556 V8 BC556 V9 BC556 R14 1K R15 10K R16 10K C7 120P VDD 1 2 3 4 5 6 7 8 RJ1 1 2 3 4 5 6 7 8 RJ2 RD 1 RE 2 DE 3 DI 4 GN 5 DO 6 DO 7 VCC 8 IC2...

Страница 10: ... 3 P5 4 P6 5 P7 6 CLK1 2 CLK2 15 PL 1 Q7 9 Q7 7 IC3 74LS165 SER 10 P0 11 P1 12 P2 13 P3 14 P4 3 P5 4 P6 5 P7 6 CLK1 2 CLK2 15 PL 1 Q7 9 Q7 7 IC4 74LS165 R1 1K R2 1K R3 1K R4 1K R5 1K R6 1K R7 1K R8 1K D1 D2 D3 D4 D5 D6 D7 D8 R17 1K S1 S2 S3 S4 S5 S6 S7 S8 VDD X1 S17 S18 S19 D17 C1 1u C2 1u C3 1u C4 1u VDD A3 CLEAR ZONE 1 ZONE 8 PAGE ALL CALL B6 B5 B3 B7 B0 BUSY B1 B7 1 2 3 4 5 6 7 8 9 10 NC B0 B1 ...

Страница 11: ...CLK2 15 PL 1 Q7 9 Q7 7 IC3 74LS165 SER 10 P0 11 P1 12 P2 13 P3 14 P4 3 P5 4 P6 5 P7 6 CLK1 2 CLK2 15 PL 1 Q7 9 Q7 7 IC4 74LS165 R1 1K R2 1K R3 1K R4 1K R5 1K R6 1K R7 1K R8 1K R9 1K R10 1K R11 1K R12 1K R13 1K R14 1K R15 1K R16 1K D1 D2 D3 D4 D5 D6 D7 D8 D9 D10 D11 D12 D13 D14 D15 D16 R17 1K S1 S2 S3 S4 S5 S6 S7 S8 S9 S10 S11 S12 S13 S14 S15 S16 VDD VDD X1 S17 S18 S19 D17 C1 1u C2 1u C3 1u C4 1u V...

Отзывы: