background image

Installation Notes

•  Read all precautions, installation and operating 

instructions carefully and completely before 
installing the unit.

•  Ensure all contents are present prior to 

installing.

•  Lay out system in appropriate configuration.  

Improper sequence of equipment will affect 
performance, and could possibly damage your 
system.

•  For systems with pro-grade installation kits, 

anticipate the addition of pex tubing, clamps 
and mounting screws to install unit properly 
(available at your local home improvement 
store or through your plumbing contractor). 
Due to the varieties of home design, not all 
configurations can be addressed in this guide.  
Components and time of installation will vary. 
Please refer your plumbing professional to our 
Installation Guide.

•  Do not install this filter where the line pressure 

may exceed 100 psi. Operating pressure range: 
20psi – 100psi.

•  Select an appropriate installation location.  

Dimensions of systems vary—always allow an 
estimated minimum of 50” clearance for height 
of tank, and a minimum of 30” for floor space. 
Your plumber will be installing the system in 
an area where the main water line enters your 
home, prior to your water heater.

•  Do not install the unit on its side or in direct 

sunlight. Outdoor installation requires the use 
of sunproof sumps.  Please contact our sales 
and service department 866-238-5855 to 
discuss the specifics of your installation.

•  Full warranty contingent on installation by a 

licensed plumber.

•  Install on cold water lines only (40° – 90°F). 

Protect unit from freezing.

•  Installation of the filter must comply with 

existing state and local plumbing codes. 
Austin Springs is not liable for consequential 
or incidental damages due to  improper 
installation. 

Do not use with water that is microbiologically unsafe or of 

unknown water quality without adequate disinfection before or 

after the system. Systems certified for cyst reduction may be used 

on disinfected water that may contain filterable cysts.

Installation

1. KEEP UPRIGHT AT ALL TIMES.

2. Remove the red shipping caps from the inlet & 

outlet ports on the main housing. 

3. Precondition by “surge flushing”:

  It is 

important that this system is flushed prior 
to installation. The granular medium used in 
the bottom tank contains 1-2% by volume of 
carbon fines that should be flushed out prior 
to use. The best method for purging these 
carbon fines is “surge flushing”: 

  Using the supplied adapter, 

connect a garden hose to the 
inlet port so that the water 
will flow into the system and 
out of the outlet port. Slowly 
turn on the water and allow 
the discolored water to flow 
into a bucket or drain. The 
first few gallons will appear black 
and cloudy. After an initial 
2-5 minute flushing, begin a 
period of “surge flushing.”  
Turn the water on for 30 
seconds and then off for 30 
seconds repeatedly for 5-10 
minutes or until initial surge 
of water is completely clear and 
free from discoloration and cloudiness. Once 
the unit has been flushed, be sure the white 
washers are properly set inside the inlet and 
outlet ports. Disconnect it from the hose and 
position it for final installation.

4. Turn off main source water supply prior to 

installation. 

5. Install the unit to the main water supply 

using the supplied components. Do not over 
tighten fittings, as this may cause leakage 
and broken fittings. Do NOT use pipe dope. 
The use of pipe dope voids the warranty. 
You may use NSF Certified pipe primer, glue 
and teflon tape. Leave two-three threads 
exposed and do not exceed seven layers 
of teflon tape. More than seven layers will 

cause the nipple to crack and leak.

6. IMPORTANT:

  

The inlet piping assembly 

(valve, pre-filter, main filter 
unit, union and nipples) 

must be firmly braced and 

supported.

7. Once installation is complete, slowly 

turn the water on and inspect for 

leaks.

8. Once the unit is installed 
and checked for leaks, open 

the water faucet closest to the 

installed unit and allow water 

to run for 10 minutes for the final 

flushing period.

9. This unit must be installed by a licensed 

plumber to validate the warranty.

Flush

for

10

  

min.

Flush

for

10

  

min.

Specifications

Model: 

AS-400

Replacement cartridges 
 

Main tanks: 

AS-400R

 

Pre-filter: 

AS-WH-PRE-4-R

 

Post-filter: 

AS-WHPOST-R

Содержание AS-400

Страница 1: ...Installation Instructions AS 400 Whole House Water Filter ...

Страница 2: ...me to replace the filter with a new one Allowing sediment to continue to collect can cause clogging and restrict the flow of water into your home AS 400 Whole House filter Replace the main tanks every 400 000 gallons You may consider adding a meter to your system at the time of installation Typically the average family of four will consume that amount in 4 6 years Unions are located on each side o...

Страница 3: ... AT ALL TIMES 2 Remove the red shipping caps from the inlet outlet ports on the main housing 3 Precondition by surge flushing It is important that this system is flushed prior to installation The granular medium used in the bottom tank contains 1 2 by volume of carbon fines that should be flushed out prior to use The best method for purging these carbon fines is surge flushing Using the supplied a...

Страница 4: ...from for a Return Authorization Code and a full refund will be promptly issued upon return This filter system is designed and tested for use with genuine Austin Springs parts including replacement filters and all hardware Use of parts from other manufacturers may result in loss of contaminant reduction performance system damage or failure Use of parts from other manufacturers will also void your w...

Страница 5: ...Austin Springs 1609 Shoal Creek 200 Austin Texas 78701 866 238 5855 AustinSprings com AS 400_20150714 ...

Отзывы: