![Austin Hughes CyberView RP-HW719 Скачать руководство пользователя страница 16](http://html.mh-extra.com/html/austin-hughes/cyberview-rp-hw719/cyberview-rp-hw719_user-manual_3019283016.webp)
UM-CV-751-RP-HW719-Q221V1 www.austin-hughes.com
P.12
USB Touchscreen
Power
VGA
DVI-D
Model
TRB
e-Resistive
TCB
e-Capacitive
Technology
5-Wire Resistive
Capacitive
Touch Point
Single
Single
Method
Stylus or Finger
Finger
Activation Force
≤ 50g / Stylus=R0.8
≤ 50g
Durability
35 million touches
300 million touches
Response Time
15 ms
20 ms
Optical Transmittance
80% ± 3%
87% ±2%
Surface Hardness
3H
9H
Haze
8% ± 3%
7%
Glass
3.2 ±0.2 mm
2.8 mm ±10%
Connector
USB Type A
Compatibility
Windows 7 / XP / Vista, Linux
< 3.6 > Options : Touchscreen & driver
W19" USB Touchscreen Specification
Step 1.
Run the bundled CD disc or download the driver from the link below :
http://www.austin-hughes.com/resources/driver/rackmount-display
Step 2.
Double click the Setup.exe
Step 3.
Follow the installation instruction to finish the setup
Step 4.
After installation, run the TouchKit program & the “4 point calibration”
Please follow the below steps to setup the touch screen:-
Please do the initial calibration
after the first setup
■
USB touchscreen package includes 1 x 6ft USB cable, quick reference guideline and CD disc
■
For detailed information, please refer to the attached CD disc
■
As the touchscreen unit is not made of toughened glass, please handle it carefully