background image

        6.1.1      User Administration

                         At startup of the AP, the system will prompt user to enter the password to access to the system. The administrator  
 

        can add or remove a user easily via the web pages. 

 

        There are two levels of access privileges:

 

        User Name 

               Default Password 

            Access Privileges                      

 

        root   

               root 

 

            full access

 

        (user define)                 (user define) 

            only can access to Serial Port and System Status & log

 

        

       
        6.1.2      Add User

 

        To add a user,

 

        

   

Check the users at the User administration screen

 

        

   

Click the button Add 

                         Figure below shows the Add User screen.

 

         You will see the new user is on the user list now.

6.1   System Administration                                                       

Chapter 6

P.26

Note :

 

   

The first character of User name must be alphabet. 

   

The password should be at least 3 characters long.

   

The user name or password must not longer than 32 characters.

   

Only root user can access to Network and System administration.

Содержание Cyberview CS-116

Страница 1: ...User Manual CS116 148 Cat5 IP Serial Console 1U 16 48 ports Remote IP access using SSH or telnet clients ...

Страница 2: ... 3 Device Setup 8 10 Chapter 3 IP Setting 3 1 IP Configuration 11 3 2 IP Filtering 12 13 3 3 Web Server Configuration 13 15 Chapter 4 Serial Port Configuration 4 1 Serial Port Configuration 16 21 4 2 Connection 21 22 4 3 Serial to Serial Function 23 24 Chapter 5 System Status Log 25 Chapter 6 System Setting 6 1 System Administration 26 27 6 2 Date and Time 28 6 3 Fireware Upgrade 29 30 Chapter 7 S...

Страница 3: ...Chapter 8 Optional Specifications 8 1 DC Power Options 34 Chapter 9 FAQ 35 Chapter 10 Dimensions 36 Contents ...

Страница 4: ...ire water lightning or other acts of nature unauthorized product modifi cation or failure to follow instructions supplied with the product Repair or attempted repair by anyone not authorized by us Any damage of the product due to shipment Removal or installation of the product Causes external to the product such as electric power fluctuation or failure Use of supplies or parts not meeting our spec...

Страница 5: ...ng time disconnect it from the power outlet to prevent being damaged by transient over voltage Keep all liquids away from the equipment to minimize the risk of accidental spillage Liquid spilled on to the power supply or on other hardware may cause damage fire or electrical shock Only qualified service personnel should open the chassis Opening it yourself could damage the equip ment and invalidate...

Страница 6: ...erial console x 1 pc RJ45 DB9 female adapter x 1 pc RJ45 DB9 male adapter x 1 pc Screw M3 2 x 4 5mm x 4 pcs Screw M4 x 10mm x 8 pcs User manual x 1 pc CD dic x 1 pc Power cord x 1 pc Bracket x 1 set 5 4 2 6 1 3 User Manual 1 6 5 4 3 2 8 9 7 8 7 9 ...

Страница 7: ... included and in good condition If anything is missing or damage contact the supplier immediately 1 5 Unpacking 1 4 Before Installation Chapter 1 1 6 Optional Accessories 1 RJ45 DB9 adapter 1 1 SG 100F RJ45 DB9 female adapter 1 2 SG 100M RJ45 DB9 male adapter 2 Cat5 Cable 2 1 CU 3 3 feet Cat5 cable 2 2 CU 6 6 feet Cat5 cable 2 3 CU 10 10 feet Cat5 cable 2 4 CU 15 15 feet Cat5 cable 2 5 CU 33 33 fe...

Страница 8: ...ed shown in Figure 1 Fix the Cat5 IP serial console into the rack Hardware for fixing the mounting bracket to the rack is not provided Figure 1 Installing the rear L bracket to the Cat5 IP serial console Figure 2 Fixing the Cat5 IP serial console into the rack A B screw A M3 2 x 4 5 mm screw B M4 x 10 mm ...

Страница 9: ... IP Serial Console SG 100F RJ45 DB9 female adapter Cat5 cable Computer with RS 232 serial port Hub Router Switch PDU UPS Power module Serially managed device SG 100F RJ45 DB9 female adapter SG 100M RJ45 DB9 male adapter Cat5 cable Cat5 cable Cat5 cable Internet Hub for remote access Headless servers ...

Страница 10: ...ected 16 ports 48 ports Port activity Status LEDs Reset button Power Red Power on indication Link Orange 10BaseT Etherent connection Green 100BaseT Ethernet connection Ready Green Blinking per second when system is busy Port LED Green Traffic activity Reset button Press reset button to reboot the unit P 7 Front Panel Port LED Indications ...

Страница 11: ...arity none Flow control none 3 Enter the user name and password in order to access to the system User Name Default Password root root The following figure depicts the structure of the interface Network IP Config The following shows the IP configuration items 1 For IP mode you can press SPACE bar to select Static mode or DHCP mode 2 For IP Address Subnet mask Default Gateway Primary DNS and Seconda...

Страница 12: ...ne Then click Update Device The new settings will be save to the IP serial console unit then the unit will be reboot automatically Access IP serial console Using the HTTP protocol and entering the configured IP address of IP KVM switch into the web browser to remote access the IP KVM switch With successful connection to IP KVM the login page will show as below then key in the default user name pas...

Страница 13: ...en Selecting an item on the menu bar opens a tree view of all the submenus available under each grouping Selecting a submenu item will allow the user to modify parameter settings for that item Every page will allow the user to Save to flash Apply or Cancel their actions To apply all changes made the user must select Apply Only when the user selects Apply will the new parameter values be applied to...

Страница 14: ...3 211 The onfiguration setting will not go into effect until clicking the button Save to flash reboot 3 1 2 SMTP Configuration The IP serial console IPCS can send an email notification when the number of system log messages reaches to certain value and or when an alarm message is created due to an issue with serial port data The user must configure a valid SMTP server to send these automatically g...

Страница 15: ...8 1 254 192 168 1 0 255 255 255 0 192 168 0 1 192 168 255 254 192 168 0 0 255 255 0 0 192 168 1 1 192 168 1 126 192 168 1 0 255 255 255 128 192 168 1 129 192 168 1 254 192 168 1 128 255 255 255 128 The Port is a port or port range of the IP serial console which hosts try to access to Chain rule The chain rule determines whether the access from the hosts is allowed or not It can be one of the these...

Страница 16: ... rule 2 So only the hosts which elong to the subnet 192 168 1 x or 192 168 2 x can access to the IPCS through http by the 1 2 and 3 rules The IP serial consoloe Web server supports both HTTP and HTTPS HTTP over SSL services simulta neously Users can select user authentication method for the IPCS web pages login The IP serial console currently provides authentication methods of Local and RADIUS 3 3...

Страница 17: ...on Center http members dyndns org The user may then add a new Dynamic DNS Host link after logging in to their Dynamic DNS Network Services Members NIC After enabling the Dynamic DNS service in the Dynamic DNS Configuration menu the user must enter the registered Domain Name User Name and Password After applying the configuration change users can accessthe IPCS using only the Domain Name The DNS Do...

Страница 18: ...s who access the serial port When the authentication is set to Local the IPCS will use its own user list to authenticate a user If configured otherwise the IPCS will request authentication from the external authentication servers i e RADIUS Figure below shows conceptually the user authentication process when using an external authentication server Radius server configuration 3 3 Web Server Configu...

Страница 19: ...tication is set to Local the IP serial console will use its own user list to authenticate a user If configured otherwise the IPCS will request authentication from the external authentication servers i e RADIUS Figure below shows conceptually the user authentication process when using an external authentication server 4 1 2 Port Enable Disable Each serial port can be enabled or disabled A disabled ...

Страница 20: ...s can enter descriptive information for each port based on the device attached to it We can use the shortcut Move to on the up right corner to go to the wished port page directly P 17 4 1 Serial Port Configuration Chapter 4 ...

Страница 21: ... in the following sections P 18 4 1 Serial Port Configuration Chapter 4 Note The Power Control Mode is available in port 1 only The last port e g Port 16 of IPCS 16 can also be used as External ESP Entry Serial Port in Serial to Serial operation mode Refer to the section Serial to Serial Function for details ...

Страница 22: ...ata activity in the serial port the existing TCP session will automatically be closed If the user wants to maintain the connection indefinitely configure the inactivity timeout period to 0 TCP Keep alive no configuration required In order to avoid TCP connection lockup the IP serial console will continue to check the connection status between the Telnet SSH client and the IP serial console by send...

Страница 23: ...e data receiving from the tracking serial port will be buffered in IPCS memory The user can also define keywords for each serial port that will trigger an email notification if the keyword is found in the logged data This will enable the user to monitor the data from the attached device The Port logging feature is valid and visible only if the operation mode of the serial port is configured to con...

Страница 24: ...web pages provide a web based serial port connection which enables the user to access the serial ports without using the Telnet client program A Java applet is used to provide the text based user interface to access the serial port This Java applet supports only Telnet in Console Server mode The user cannot access the serial port via the web when the host mode of the port is set to Raw TCP connect...

Страница 25: ...ect the Serial port connection menu item click the terminal icon at C column If connect success the terminal emulation will pop up login prompt 3 Enter user name and password to log in so can start to use it as if running a Telnet client program e g Telnet DOS program PuTTY 4 2 Connection Chapter 4 P 22 ...

Страница 26: ... will be between the ESP and one of the other external serial ports e g Port 1 15 if CS 116 Internal ESP It is located on the main board inside the IPCS unit We have to uncover the metal case so can access to it The data transfer will be between the ESP and one of the other external serial ports e g Port 1 16 if CS 116 To configure the Serial to Serial function 1 Enter VT100 console mode see the s...

Страница 27: ... values 4 3 2 Serial Power Control Function The Serial Power Controller SPC is a family of intelligent power distribution units that enables remote power control of servers and network appliances When used in conjunction with IP Console Servers the SPC provides comprehensive management capabilities and quick problem resolution by integrating console access with power control into a single interfac...

Страница 28: ...s page will be automatically refreshed every 10 seconds to show the system current time 5 1 2 System Logging The user may configure the IP serial console to enable or disable the system logging process and set the storage location The system log buffer is pre allocated at 300K bytes size If the logging data grows larger than the pre allocated size the new data will overwrite the old data 5 1 Syste...

Страница 29: ...efine only can access to Serial Port and System Status log 6 1 2 Add User To add a user Check the users at the User administration screen Click the button Add Figure below shows the Add User screen You will see the new user is on the user list now 6 1 System Administration Chapter 6 P 26 Note The first character of User name must be alphabet The password should be at least 3 characters long The us...

Страница 30: ...articular port may only allow the authorized users to access To edit the ACL Check the users at the User administration screen Click the Edit icon Enter user name password Select the port to access to Click the button Submit 6 1 5 Change password To change the parameters of the user account open the edit user screen by selecting the user name at the user administration screen and then edit the par...

Страница 31: ...l battery backup By convention weather scientists use one time zone Greenwich Mean Time GMT This time is also known as Universal Time UTC The user may also need to set the time zone and the time offset from UTC depending on the user location to set system date and time exactly and the time offset from UTC It allows the IPCS to calculate the exact system time The Time offset value x could be positi...

Страница 32: ...06 6 3 2 Upgrade from web page Key in TFTP server IP address and image file name then click Apply After a few seconds the message Flash program finished successfully will be shown meaning the new firmware has been upgraded into the Flash memory 6 3 Fireware Upgrade Chapter 6 P 29 Warning During this upgrading process we should not disconnect the power or the Ethernet cable since it may cause upgra...

Страница 33: ...y green LED will blink every second P 30 6 3 Fireware Upgrade Chapter 6 Warning A new firmware release version may need one two or up to three images to upgrade You have to up grade all to be upgraded images before rebooting the system Otherwise may cause inconsistency be tween kernel and application firmware and the system may not be able to start up successfully In this case we have to upgrade t...

Страница 34: ...P Dynamic DNS Protocols Relative Function Port monitoring Serial TCP inactivity time Management Local console web pages HTTP HTTPS SSH telnet port buffering and logging system statistics Email notification according to the equipment alarm message Compatibility SUN Solaris IBM RS 6000 AIX SCO Unix Xenix interactive Unix systemsPC based headless server terminal server router firewall switch Power In...

Страница 35: ...P 32 7 2 Connector Pin Assignment Chapter 7 Console port serial port pin assignment Pin Signal Direction 1 DSR In 2 RTS Out 3 GND 4 TxD Out 5 RxD In 6 DSR 7 CTS In 8 DTR Out Pin 1 Pin 8 ...

Страница 36: ...ograms executed by privileged users Table below shows some of the well known port numbers For more details please visit the IANA website http www iana org assignments port numbers Port Number Protocol TCP UDP 21 FTP File Transfer Protocol TCP 22 SSH Secure Shell TCP 23 Telnet TCP 25 SMTP Simple Mail Transfer Protocol TCP 37 Time TCP UCP 39 RLP Resource Location Protocol UDP 49 TACACS TACACS UDP 53...

Страница 37: ... range 9 18V 18 36V 36 75V Input current No load 50 mA 50mA 50 mA Full load 4950 mA 2450 mA 1220 mA Output rating Output voltage 12 Volt 12 Volt 12 Volt Output current 4 16A 4 16A 4 16A Efficiency 84 85 85 Remarks Package does not include power cord 8 1 DC Power Options Chapter 8 ...

Страница 38: ...ervers We provide RJ45 DB9 female RJ45 DB9 male adapters convert standard serial connections to RJ45 4 How many users can concurrent remote access console server The users can concurrent remote access console server webpage is unlimited but every port can only be accessed by one user at the same time The different port can also access at the same time 5 How can we access the serial devices or head...

Страница 39: ...D x H Packing Dimension W x D x H Net Weight Gross Weight CS 116 443 x 180 x 44 mm 17 3 x 7 1 x 1 73 510 x 440 x 77 mm 20 1 x 15 7 x 3 3 5 kg 8 lb 4 5 kg 10 lb CS 148 443 x 180 x 44 mm 17 3 x 7 1 x 1 73 510 x 440 x 77 mm 20 1 x 15 7 x 3 3 5 kg 8 lb 4 5 kg 10 lb ...

Страница 40: ...thout prior notice and assumes no reponsibility for any error which may appear in this publication All brand names logo and registered trademarks are properties of their respective owners Copyright 2007 Austin Hughes Electronics Ltd All rights reserved CV CS15 0807V1 ...

Отзывы: