9
English
Regulator and hose
1. Use only regulators and hose approved for LPG at the
above pressures. The life expectancy of the regulator
is estimated as 10 years. It is recommended that the
regulator is changed within 10 years of the date of
manufacture.
Note:
Take care of the blockage of the Venturi or
Venturis.
2. The use of the wrong regulator or hose is unsafe; always
check that you have the correct items before operating
the barbecue.
3. The hose used must conform to the relevant standard
for the country of use. The length of the hose must be
1.5 meters (maximum). Worn or damaged hose must be
replaced. Ensure that the hose is not obstructed, kinked,
or in contact with any part of the barbecue other than at
its connection.
4. The hose should not be twisted or kinked when attached
to the gas cylinder.
5. No part of the hose should touch any part of the
appliance.
Gas cylinder
1. The appliance can be used with any gas cylinder of
weights between 4.5KGS and 15 KGS butane and 3.9
KGS to 13 KGS propane. The
gas cylinder should not be
dropped or handled roughly! If
the appliance is not in use, the
cylinder must be disconnected.
Replace the protective cap on
the cylinder after disconnecting
the cylinder from the appliance.
Warning:
Close the valve on the
gas cylinder if you smell gas.
2. Cylinders must be stored
outdoors in an upright position
and out of the reach of children.
The cylinder must never be
stored where temperatures can
reach over 50
o
C.
Note:
The gas cylinder is not allowed to be placed behind
the barbecue doors.
3. Do not store the cylinder near flames, pilot lights or other
sources of ignition. DO NOT SMOKE.
Operation
310
500
Содержание AABQ 3.0
Страница 1: ...AABQ 3 0 Four burner grill User Manual English Svenska Norsk ...