Aussie Pumps QP Скачать руководство пользователя страница 7

Australian Pump Industries 

Page 

7               document number: QPWP151204

 

 

4.  MAINTENANCE AND REPAIR 

a.  Disconnect spark plug wire while performing maintenance or repair 

on the pump or engine. 

b.  Always replace safety devices removed during service or repair 

before operating. 

 

5. 12-VOLT ELECTRICAL SYSTEM 

a.  Connect negative battery lead to ground to prevent damage to 

charging system. 

b.  To prevent arcing, when removing battery, disconnect negative lead 

first.  When replacing battery, connect negative lead last. 

c.  Do not spill battery acid.  If spilled, rinse off immediately with water. 

 

6.  DIESEL 

Follow engine manufacturer instructions explicitly on hand cranking. 

 

7.  OVERHEATING – DO NOT RUN THE PUMP FOR OVER TEN MINUTES 
WITHOUT WATER FLOWING THROUGH IT! 

Overheating pumps can cause severe burns and injury.  If overheating 
of pump casing occurs: 

a.  Stop the pump immediately. 
b.  Allow the pump to cool completely. 
c.  Slowly and cautiously vent the pump. 

 
 

C.  ELECTRIC MOTOR POWERED PUMPS 
 
1.  GROUND FAULT CIRCUIT INTERRUPTER 

Never operate a pump with a plug-in type power cord without a ground 
fault circuit interrupter. 

 
2.  WET HANDS 

Never handle energized power cords with wet hands. 

 
3.   WATER 

Never let extension cords or the plug connection lay in water.  Locate 
the pump such that it cannot fall into the water (except when using the 
Submersible pumps.) 

 
4.   EQUIPMENT 

Never use cords with frayed or cut or brittle insulation.  Check  the cord 
on the pump for nicks in the insulation and for sound connections to 
the ground fault interrupter plug and motor. 

 
5.  QUALIFIED ELECTRICIAN 

Any wiring to be done on pumps should be done by a qualified 
electrician. 

 

Содержание QP

Страница 1: ...dy If a hose is used it should be of the reinforced type to prevent collapsing under vacuum All suction system pipe or hose and connections must be free of air leaks as even a very slight leak will greatly reduce pumping efficiency and priming ability The pump should be installed with the trash strainer on the suction line to prevent oversize solids from being drawn into the suction system Dischar...

Страница 2: ...e are no suction line leaks B 5 Shutdown Operation is stopped by stopping the engine as outlined in the Engine Instruction Manual Always operate at no load for 2 or 3 minutes to allow cooling before shutdown When the pump has been operating in freezing weather or in pumping liquid containing considerable amounts of trash and or foreign matter it is advisable to remove both the drain plug and the p...

Страница 3: ...et bolts evenly and tightly b Impeller a Disclose the impeller by removing the volute casing same way as above b Loosen the impeller by tapping gently with a mallet in a counter clockwise direction c Turn impeller counter clockwise and remove from shaft d Remove the mechanical seal from the impeller and set it at the back side of new impeller e Screw the new impeller on engine shaft by turning in ...

Страница 4: ...ed with new rotary section spring Check to see if the mechanical seal O ring is placed correctly to the seat h Set new mechanical seal rotary section and spring with the sleeve to fit the slit of the sleeve with spring stopper i Screw the impeller as described above Troubleshooting PROBLEM CAUSE REMEDY Pump does not turn over Impeller jamming Adjust impeller spacing disassemble and clean Air leak ...

Страница 5: ...L 1 USE COMMON SENSE Most accidents can be avoided by using common sense and concentrating on the job to be done 2 Do not wear loose clothing that can become entangled in operating machinery 3 Do not operate pump without guards in place 4 Do not pump hazardous material flammable caustic etc 5 Only qualified personnel should install and operate pump 6 Secure the pump after it is in its operating po...

Страница 6: ...exhaust fumes when working in the area of the engine Exhaust gases are colourless odourless and deadly poison c Never operate near a building where exhaust gases can seep inside for example through an open window or a door d Never operate in a pit or sump without making provisions to suck the exhaust gases out 2 EXHAUST SYSTEM a Keep exhaust system components tight and in good working condition b ...

Страница 7: ...T WATER FLOWING THROUGH IT Overheating pumps can cause severe burns and injury If overheating of pump casing occurs a Stop the pump immediately b Allow the pump to cool completely c Slowly and cautiously vent the pump C ELECTRIC MOTOR POWERED PUMPS 1 GROUND FAULT CIRCUIT INTERRUPTER Never operate a pump with a plug in type power cord without a ground fault circuit interrupter 2 WET HANDS Never han...

Страница 8: ...ircuits are dead and locked out before doing any maintenance or repair work on the pump 8 MOTOR OVERLOAD Do not exceed the manufacturer s recommendation for maximum lift or discharge head as this could cause the motor to overheat Use appropriate circuit breaker for fuse 9 EXPLOSIVE ATMOSPHERE Unless the pump has been designed for it never use it in any kind of possible explosive atmosphere CAUTION...

Отзывы: