www.ausrv.com
Ph: 833 872 8778
70
Problem
Potential Cause
Resolution
No hot water at
the faucet
Gas supply is turned off or
interrupted.
Check and/or turn on gas supply.
Gas tank is empty
Refill/replace the gas tank.
The appliance is switched off.
Switch on the appliance according to instructions (refer to
“Operating procedures” on page 54).
Fresh water supply is turned off.
Open the fresh water supply.
Power supply to the appliance is
switched off.
Switch on power supply to the appliance.
Defect in the appliance.
LED 2 flashes red (refer to “APPENDIX A - Error Codes”
on page 68) and contact a certified service technician if
necessary.
Boiling noises
Too much lime scale in the AquaGo
instant water heater.
The appliance must be decalcified (refer to “Decalification”
on page 62).
Hot water
temperature too
low
Gas flow to the appliance is too
low (gas inlet pressure < 10.5 in.
wc).
Consult vehicle documentation to determine if the gas
supply is capable of providing the necessary volume of gas
for the appliance.
Contact a service technician to verify that the gas installation
is suitable
Volume flow of hot water is too
high and/or temperature of cold
water reaching the appliance is
too low
Turn down hot water at the faucet or in the shower in order
to reduce flow rate.
Potentially retrofit a flow rate throttle in the water system.
This must be performed by a certified service technician.
Too much lime scale in the
appliance.
The appliance must be decalcified (refer to “Decalcification”
on page 62).
Water escaping
at pressure relief
valve.
Water pressure in water system
too high
Adjust the water pump pressure to a maximum of 65 psi
(4.5 bar). If the water system is connected to a central
water supply higher than 65 psi (4.5 bar) (rural or urban
connection), a pressure reducer must be used.
Install a
pressure reducer (e.g. Truma pressure reducer) at the fresh
water supply.
Water cannot expand in the water
system.
Contact the vehicle manufacturer about retrofitting a
pressure compensation element.
Lime or dirt under the pressure
relief valve seat.
Allow the appliance to cool and then slowly raise the test
lever (Fig. 3 – 4a) to flush the water system and attempt to
force dirt or foreign matter out of the pressure relief valve
seat.
Replace pressure relief valve. This must be performed by a
Truma certified service technician.
Water escaping at
water inlet filter
Lime or dirt under the O-ring
seats.
Clean the O-rings and their corresponding sealing surfaces
with clean water.
Troubleshooting
Содержание X15 2021
Страница 76: ...www ausrv com Ph 833 872 8778 76 Electrical Diagram ...
Страница 80: ...www ausrv com Ph 833 872 8778 80 Hub Assembly ...
Страница 81: ...www ausrv com Ph 833 872 8778 81 Trailing Arms and Bushes ...
Страница 105: ...www ausrv com Ph 833 872 8778 105 Trip Name Date Miles Start Miles Finish Cumulative Miles ...