CORRECT ASSEMBLY OF BURNER HEAD
FOR CK801NG/PG and CK802 NG/PG Models Only
TO GAS FITTERS - BEFORE LEAVING AFTER INSTALLATION
1. Make sure all connections are gas tight and have no gas leakage.
2. Check that the aeration control is adjusted to the right position to enable the burner to achieve
a blue and vigorous flame to reach complete combustion.
3. Make sure the flame is normal when adjusted to low flame; there should be no yellow flames at
anytime.
4. Check there is no backfire when the appliances is turned down to low or turned off.
5. The main gas supply valve is off
6. The gas control on the appliance is off
7. The consumer fully understands the safety precautions, operation and maintenance
8. The operation of the ignition system is satisfactory.
9. If a normal flame cannot be achieved after adjusting the aeration control plate, please contact
Austcrown Pty Ltd for assistance.