background image

 

www.auruslocks.com 

 

C. Lock and unlock using card and password

 

 

Use Password to Unlock 

 

 

For the first time 

input the default factory password “1234+ OK” or input the factory default 

management password “1OK” 

 

  You will hear a beep and the green LED  

flashes.  

  The lock will unlock.  

  The Latch will come out automatically after 5s to lock.  

Note: - in case of wrong password, you will hear 3 beeps signaling the wrong passwords.  

           In case of low voltage/battery the lock show this sign 

           The user and the management password cannot be same.  

 

Use Card to Unlock 

 

Show the registered card near the card inductive zone icon

 

 

You will hear a beep and the green light 

is on.

 

 

The lock will unlock. 

 

Note: - in case the card is unverified, you will hear 3 beeps.

 

 

D. How to Change Management password. 

  Input the current management 

password “12 C’’ 

 

You will hear a beep and the green light 

flashes quickly

 

 

Enter the new Management password you wish to set  

 

 

P

ress “Ok” 

 

 

You will hear a beep implying that you have successfully changed the password. 

 

 

Verify the working with the new password while the drawer/cabinet is open. 

 

 

E. How to Change User password. 

 

Input the current user password “1234 + C’’ 

 

You will hear a beep and the green light 

flashes quickly

 

 

Enter the new user password you wish to set  

 

 

Press “Ok” 

 

 

You will hear a beep implying that you have successfully changed the password. 

 

 

Verify the working with the new password while the drawer/cabinet is open. 

 

 

IMP: - Check the locking and unlocking of the lock while the 
DRAWER/CABINET IS OPEN. The Pin should consist of 4-15 digits.  

Содержание PN-19RF

Страница 1: ...on 2 1 Unlocking Modes 2 Getting Started 2 1 Unlock and lock using card and password 3 2 How to Change Password 3 3 Adding Management Card 4 4 Adding User card 4 5 Delete cards 4 5 Other features 5 6 Tips 5 User s Manual PIN RFID CABINET LOCK PN 19RF ...

Страница 2: ... 5 MHz is also available on order General Introduction ________________________________________________________________________ B Getting Started Please insert 4 AA batteries The product will be given to you in demo mode the default password is 1234 ok and the factory default management password is 12345678 OK Touch Panel Card Inductive Zone USB Key Interface Reset ...

Страница 3: ...ock Note in case the card is unverified you will hear 3 beeps D How to Change Management password Input the current management password 12345678 C You will hear a beep and the green light flashes quickly Enter the new Management password you wish to set Press Ok You will hear a beep implying that you have successfully changed the password Verify the working with the new password while the drawer c...

Страница 4: ...r card you want to add This will be your User card You will hear a beep implying that you have successfully added the user card You can continue adding card if you wish to add more NOTE You can only add upto 27 user cards H Delete all cards all cards Input the current management password Press C You will hear a beep and the green light will start to flash Press ok Low voltage indicator will start ...

Страница 5: ...supply When the battery is too low and lock cannot be operated You can connect the USB port with an external power supply and operate the lock to open and replace the batteries 5 In case the management card is or all cards need to be deleted press the reset button and the passwords will be reset to factory settings I Tips Problem Cause Solution After entering the password the lock beeps 3 times Ba...