![Aurora THE ELEMENTAL SUSPENDED FIRE Скачать руководство пользователя страница 14](http://html1.mh-extra.com/html/aurora/the-elemental-suspended-fire/the-elemental-suspended-fire_installation-and-user-manual_3018448014.webp)
14
25MM MINIMUM CLEARANCE
25MM MINIMUM CLEARANCE
25MM
CEILING COVER PLATE
SUPPORT TO SPAN
ACROSS CEILING JOISTS
FLUE CAP IN THE TOP
OF THE FLUE
THE LARGEST SQUARE
SECTION MUST PROTRUDE
DOWN FROM THE CEILING A
MINIMUM 25MM UNLESS THE
CEILING IS MADE FROM A
NON-COMBUSTIBLE MATERIAL
SUCH AS CONCRETE
CEILING
FLAT CEILING INSTALLATION:
The bracket must be structurally secured within the roof, as shown on the diagram.
The large square body of the ceiling bracket must protude down through the fi nished
ceiling level by a minimum of 25mm.
You must leave a 25mm clearance gap between the bracket and the ceiling. The gap
will be covered by the ceiling cover plate.
SUSPENSION BRACKET
FLUE
Содержание THE ELEMENTAL SUSPENDED FIRE
Страница 2: ...2...
Страница 4: ...4...
Страница 5: ...1 PLANNING...
Страница 8: ......
Страница 9: ...2 DIMENSIONS SPECIFICATIONS...
Страница 11: ...AURORA SUSPENDED FIRES 11 CEILING BRACKET FLUE FIREBOX...
Страница 12: ......
Страница 13: ...3 INSTALLATION...
Страница 22: ...61 0 2 6686 8408 4 1 Simmons Street Ballina NSW 2478 Australia www aurorasuspended res com Aurora...