3.  Safe positioning

 

Only ever use the appliance in an upright position;

 

When  portable,  always  maintain  a  distance  of  at  least  1m  between  the  product  and  any  inflammable
object/surface.

 

When the product is wall mounted, make sure that the minimum distances reported in pictures 1 and 2
are respected. Do not place the heater so that the air flow blows directly towards the wall.

 

As the heater is a class 2 product, earth connection is not required.

 

The  heater  has  an  IPX1  protection  level  against  water  and,  if  wall  mounted  may  be  installed  in
bathrooms. In any case you have to respect the national installation standard and safety requirements
valid in your State.

 

Never install/use this appliance in the Zones 0, 1 or 2 illustrated in picture 3:

 

On no account must any switch / button be accessible by people in the shower or in the bathtub.

4.  Wall mounting

 

After carefully reading section 3, proceed with installation following the sequence shown in picture 4.

 

To hang on the product proceed as follows (see picture 6):

-

  Lay the base of the product on the base of the wall bracket coupling the plastic ribs created to make

the lodging easier;

-

  Push a little bit the product downwards and move the upper side of the product near the bracket;

-

  Check that the upper holed rib of the bracket fits the dedicated pivot created on the back grid of the

heater. Moderately shake the heater after installation to be sure it is correctly fixed.

 

To release the product from the bracket proceed as follows:

-

 

Use your hand to  push downwards the upper rib of the bracket as much as necessary to release the
product by pulling it on the top.

-

 

Once the product has been unlocked on the upper side just pull it upwards to release it from its base.

 

IMPORTANT FOR FRANCE:
If  the  product  is  wall  mounted,  the  electrical  connection  must  be  made  according  to  the  enclosed
drawing, cutting the cable and using a connection block between the product cable and  the  electricity
supply (see picture 6).

 

In humid rooms, bathrooms or kitchens, this connection block must be installed at least 25 cm from the
floor.  The  electrical  connection  must  also  include  the  use  of  a  2-pole  switch  with  a  contact  opening
distance of at least 3 mm.

5.  Cable storage

 

While the product is not in use, you can store the cable pushing it into the base of the product.

 

Note that while the product is in operation, the cable must always be completely pulled out.

6.  Use of the heater

See picture 5

6.1 Version with switch and thermostat

 

The heater has 2 knobs controlling the switch and the thermostat.

 

The switch knob has 5 positions, allowing to select the desired power setting.

 

Starting from the “

” position, turn the thermostat knob clockwise until you hear a "click”: the appliance

starts working at the desired power setting.

 

The  thermostat  maintains  the  desired  room  temperature  switching  on  and  off  automatically  the
appliance. The more the knob is turned clockwise, the higher is the maintained temperature. Maximum
thermostat setting corresponds at about 30°C; “

” position corresponds to approximately 5°C.

 

For correct use of the thermostat , see section “ USE OF THE THERMOSTAT”

6.2 Model with thermostat and 60' timer

 

The heater has 2 knobs.

 

Turn  the  timer  knob  clockwise  to  select  the  working  time  you  prefer  from  5  to  60'.  The  heater  starts
working at full power (2000W) and thermostat setting doesn’t influence the functioning;

 

After  the  selected  period  the  heater  will  automatically  turn  to  mid  power  (1000W),  thermostatically
controlled according to  the thermostat setting. For the use of the thermostat see section 6.3.

 

When the heater is working under timer control at full power,  the  thermostat  doesn't  control  the  room
temperature. In this condition, do not use the heater in small rooms when they are occupied by persons
not capable of leaving the room on their own, unless constant supervision is provided.

6.3 Use of the thermostat

 

In a room where the temperature is too high (more than 30°C), it is normal that the thermostat will no t
switch on the heater.

 

In  a  room  where  the  temperature  is  too  low  (around  5°C  or  even  less)  it  is  also  normal  that  the
thermostat will keep the appliance working until the temperature gets higher.

 

To select the right thermostat position we suggest you to

turn the thermostat in maximum position (clockwise);

leave the appliance working until the comfortable temperature is reached;

turn the knob anti clockwise until you hear a "click" and the appliance stops;

turn clockwise again the knob (just a little): in this position the thermostat will maintain the comfortable
temperature you have selected.

7.  Safety in the event of the product not functioning normally

 

In the event of overheating, the safety system will automatically turn off the heating  elements  and  the
motor. If this happens:

switch off the fan heater using the main switch;

remove the cause of overheating (i.e. obstacles in front of the  air  inlet  or  air  outlet  grilles,  unusual
accumulations of dirt, etc);

let the heater cool down for 15/20 minutes;

switch on the fan heater and check it is functioning properly.

 

If  you  notice  irregular  operation,  damage  to  the  heating  element  or  to  the  structure  of  the  appliance,

disconnect the product from the mains power supply and contact your technical assistance center or dealer.

8.  Maintenance

 

This heater does not require any particular maintenance.

 

We recommend you clean the air inlet and air outlet grilles at least twice a year with a vacuum cleaner,
to remove dust from the motor and the heating elements.

 

If the heater needs to be repaired, please contact an authorized center.

 

If the cable is to be changed, please remember that a 2x1m

2

 H05VV-F <HAR> cable must be used.