Figure 14
Fiber Optic Cable Minimum Bend
CAUTION
:
Ensure that you inspect and clean every fiber optic connector prior to mating the
fiber ends. Failure to do so may compromise performance of the equipment, or cause
component failure
.
Take the following appropriate precautions when inspecting and cleaning fiber optics:
1.
Turn off all laser sources
2.
Ensure that the cable is disconnected from equipment at both ends of the cable
3.
Wear appropriate safety glasses if required
4.
Keep unplugged fiber connectors clean by using a protective cap, which is to be stored in a re-sealable
container when not in use.
Refer to document TN-08-001 “Cleaning Fiber Optic Connectors” for more information.
4.9.1
Steps to Connect the Optical Fiber to the ONT
Follow these steps for making connections to the ONT:
1.
Remove the protective covers from the tips of the SC optical connector at the end of the jumper or
terminated fiber cable.
2.
Insert the SC connector on one end of the cable into the ONT’s SC/APC EPON port, which is located on
the left side of the unit as viewed from the rear. The plastic cover of the SC/APC connector compartment
must first be removed. See Figure 15 for a picture of the optical EPON port with the cover removed.
Figure 15 SC/APC Optical EPON Port