USERS GUIDE
www.auroramm.com
21
RXS-1 Control Server Setup
1. Connect the RXS-1 USB to a USB Hub for keyboard and mouse use. Plug the HDMI into a monitor capable of 720p
or higher.
2. Connect power brick to the RXS-1 and into the wall.
3. Unit will boot in about 45 seconds.
4. In the lower right, use the mouse to right click on the network settings.
5. Under the IPV4 tab, add a fixed IP, unless you are using the MAC address from the switch to control the IP Address
through DHCP. It is highly recommended to have an IP Address that will not change. If a static IP is added, delete the
Auto or boot time will be very long as it searches.
Control Setup
1. In a web browser, connect to the RXS-1 Server IP Address/port number. The units on the network will populate
into the encoder and decoder fields accordingly. You will then be able to change settings, save EDID, route, and
more. If a control system is to be used, make certain it is connected to the same network and follows the Aurora
IPX API protocol.
Important:
Take note of the MAC Address of every unit. It can be found on the underside or rear of the unit. The MAC
Address is how you will identify the unit relative to its location.
Make certain all units are using the latest firmware.
Remember to setup EDID for proper operation.