GB
Aurora Limited, 6 Little Burrow, Burrowfields, Welwyn Garden City, AL7 4SW, United Kingdom
Website: www.auroralighting.com
Document version – AU-ST100_V1_17_ENG&FRE.doc
AU-ST100 - SINGLE COLOUR LED STRIP LIGHT
PLEASE READ THESE INSTRUCTIONS CAREFULLY BEFORE INSTALLATION
LEAVE A COPY FOR THE USER / MAINTENANCE ENGINEER FOR FUTURE REFERENCE
IMPORTANT INSTALLATION INFORMATION
•
Installation should be carried out in accordance with the latest edition of the National Wiring Regulations. If in doubt, consult a qualified electrician.
•
Keep the LED Driver away from direct sources of heat such as Low Voltage lamps.
•
Ensure that ALL electrical connections are tight with no loose strands, including factory connections.
•
Indoor use only.
•
Constant Voltage drivers and parallel connections must be used.
INSTALLATION INSTRUCTIONS
Before commencing installation or maintenance, ensure electricity is switched off at the mains.
1.
A 12V DC LED Driver must be used with this strip.
2.
Ensure that the surface that the LED strip will be applied to is clean and free from grease
3.
Peel of the backing tape and fix the LED strip into the required position using the self-adhesive backing.
4.
The LED strip may be cut to length with cut points every 50mm.
5.
A maximum of 10m can be connected in one length. Runs over 10m must be connected in parallel. See Diagram 1 for connection details.
6.
Connect the LED Strips to the 12V DC Constant Voltage LED Driver and ensure that the polarity is correct. Also refer to the instructions provided with the
LED Driver
7.
Connect the Constant Voltage LED Driver to the mains supply.
8.
The LED strip will now be lit.
Environmental Protection (W.E.E.E.) – Aurora’s WEEE Reg.No. WEE/BG0130YX
Waste Electrical & Electronic Equipment Regulations (WEEE) requires that any of our products showing this marking (left) must not be disposed of
with other household or commercial waste. Aurora does not levy any WEEE disposal charges to its customers for affected WEEE related products.
To prevent possible harm to the environment or human health from uncontrolled waste disposal, please separate any such product from other
waste types and recycle it responsibly at your local facilities. Check with your Local Authority, Recycling Centre or retailer for recycling advice. If,
when you purchased any Aurora product, your supplier included a WEEE disposal fee, you should then contact your supplier for advice on his take
back of the product for the correct disposal.
WARRANTY
See www.auroralighting.com for full details of warranties and Extended Warranty Terms and Conditions. The warranty is invalid in the case of improper use,
tampering, and removal of the Q.C. date label, installation in an improper working environment or installation not according to the current edition of the National
Wiring Regulations. Should this product fail during the warranty period it will be replaced free of charge, this is subject to correct installation and return of the
faulty product. Aurora does not accept responsibility for any installation costs associated with the replacement of this product. This warranty is in addition to the
statutory rights in your country of purchase. Aurora reserves the right to alter specifications without prior notice.
Diagram 1: Typical Installation with 50W Driver and 10m AU-ST100
240V ~ 50Hz
AU-ST100
AU-ST100
AU-LED5012CV
Constant Voltage
LED Driver
12V DC
12V DC
10m maximum
In one length