AUREL RTX-868-NB Скачать руководство пользователя страница 4

                                                              

 

                               

                     

RTX-868-NB

 

---------------------------------------------------------------------------------------------------------------------------------------------------------------------

                          

User manual

 

 

The technical features can change without forecasting. AUR°EL S.p.A doesn’t assume any responsibility of damage due to the improper use of the device. 

-------------------------------------------------------------------------------------------------------------------------------------------------------------------

 

AUR°EL S.p.A.

 Via Foro dei Tigli, 4 - 47015 Modigliana (FC) – ITALY 

Tel.: +39.0546.941124  Fax: +39.0546.941660

 

http://www.aurelwireless.com

  -  email: 

[email protected]

 

                                                          Preliminary 19/03/2019 

Pag  

4

 di 

8

 

 

Operation 

 

At power on the device activates the OUT pin (active high), it performs the initialization and it deactivates 
the OUT pin. 
 
After  the  power  on  initialization  the  RTX-868-NB  uses  the  WOR  (Wake  on  Radio)  functionality  which 
enables the radio to periodically wake up from sleep mode and listen for incoming packets. The radio goes 
back to sleep mode unless a packet has been detected. 
This technique, with 10 seconds wake up time, allows to receive valid RF packets with an average current 
consumption of about 10uA. 
On the transmitter side it is of course necessary transmit a long packet preamble so that the receiver can 
wake up and detect the presence of the packet. This means that the transmitted radio packet is 12 seconds 
long. 
 
The  device  is  designed  for  battery  powered,  sensors  network  requiring  very  low  power  consumption,  in 
particular for smoke and fire detection applications. 
A  typical  scenario  is  a  network  of  radio  sensors  for  residential  use,  each  integrating  the  RTX-868-NB,  a 
sensor (e.g. smoke or fire sensor) connected to the ALARM input (pin 3) and an alert notification apparatus 
(e.g. warning horn) connected to the OUT pin (pin 17). 
 
When  the  ALARM  input  (normally  high  with  65k  ohm  pull-up  resistor)  goes  low  and  stays  low  at  least 
20msec the RTX-868-NB considers the alarm activated and then it: 
1.

 

activates the OUT pin (active high) for the local warning; 

2.

 

send  the  alarm  RF  radio  packet  (12  seconds  long)  :  all  the  other  devices  of  the  network  (see  section 
below for network selection) receive the packet and then activate their OUT pin.  

  
In  a  similar  way  it  is  possible  to  deactivate  manually  the  alarm  through  the  TEST/DISABLE  input  (pin  6) 
typically connected to a push button. If the TEST/DISABLE pin (normally high with 65k ohm pull-up resistor) 
goes low and it stays low at least 3 seconds, when it goes back high the device: 
1.

 

deactivates the OUT pin (pin low) for the local warning disable; 

2.

 

send the alarm disable RF radio packet (12 seconds long) : all the other devices of the network receive 
the packet and then deactivate their OUT pin.  

 
  

 
 
 
 
 
 
 
 
 
 
 

Содержание RTX-868-NB

Страница 1: ...etection applications A typical scenario is an alarm sensor network in which each node is able to detect an alarm When a device detects the alarm it activates a node local warning and it sends a broad...

Страница 2: ...mA RF TX Frequency 1 868 1 868 5 MHz Offset frequency at 25 C 4 4 KHz RF channels 2 5 RF power 1 15 16 dBm ERP with Aurel antenna ANT 868 SMA 15 dBm Modulation GFSK Deviation GFSK modulation 15 kHz C...

Страница 3: ...emented 6 TEST DISABLE Test and alarm disable input active low normally high with 65k ohm pull up resistor 7 RF CH Sel2 RF channel selection input active low normally high with 65k ohm pull up resisto...

Страница 4: ...e is designed for battery powered sensors network requiring very low power consumption in particular for smoke and fire detection applications A typical scenario is a network of radio sensors for resi...

Страница 5: ...cted to ground It is mandatory that all the devices of the same installation work on the same RF channel In case of more than one installation in the same RF coverage area it is recommended to set eac...

Страница 6: ...UT pin 17 for about 3 seconds If the ACK packet is not received the Device 1 blinks three times the OUT pin TEST MODE setting is detected only at power on therefore for any changes of the setting it i...

Страница 7: ...placed vertically to the ground plane Other placements of antenna bend coil will work but performance are not predictable As an alternative to connect the module to an external antenna connect an SMA...

Страница 8: ...li 4 47015 Modigliana FC ITALY Tel 39 0546 941124 Fax 39 0546 941660 http www aurelwireless com email rfcomm aurel it Preliminary 19 03 2019 Pag 8 di 8 Firmware version summary Release date Firmware v...

Отзывы: