The hysteresis change mode is signaled by the flashing text
HI
. Use the
bc
buttons
to set the required hysteresis.
HI 2
- ± 0.2 ° C (factory set),
HI 4
- ± 0.4 ° C,
HI P
- PWM operating mode (chapter "PWM operating mode").
Confirm your choice by pressing
and
. AURATON Tucana will proceed to change
the next parameter.
Change the delay
The delay prevents too frequent activation of the actuating device, e.g. due to
temporary drafts (e.g. caused by opening the window).
The delay change mode is signaled by
the flashing inscription
90: SE
Use the
bc
buttons to turn the delay
on or off.
90: SE
- delay 90 seconds
(factory
setting)
0: SE
- no delay
Configuration settings
PWM operating mode
Connection diagram of AURATON Tucana