The controller also has the GUARD functions which prevents the stalling
process in the rotor of the pump when it is not in use.
If the pump is not used for a long time, the built-in processor starts the
pump automatically for 30 seconds every 14 days.
NOTE: In order for the system to work after a long period of non-use, the
controller must be switched on at all times.
GUARD function
8
Wiring diagram of the controller in the
mode
[CO]
(
work with a CH pump
)
CH boiler
temperature
sensor
pump
L
N
yellow-green
wire
blue
wire
brown
wire
+
Switching the controller off
In order to switch the controller off, press and hold for 2 seconds the (
)
[
~
]
button; the display is then switched off and the green LED changes its
color to red.
The controller is switched off but the GUARD function continues to be
active.
230V
CO
The controller is in the CH mode.
CU
The controller is in the DHW mode.
ON
The pump has been switched on in the manual mode.
Other information codes
Error information codes
T
he pump is disconnected or
defective.
N
o network synchronization
signal that protects the relay
is present.
S
ensor short circuit took
place.
L
acking or defective sensor
.
S
ensor temperature below
25°C
.
S
ensor temperature above
90°C.
High temperature warning.
CU
mode –
the pump has been switched off;
waiting for the defect to be repaired
(replacement of a sensor). Once the defect
has been repaired, press any button.
CO
mode –
the pump has been switched
on.
The pump has been switched off; waiting for
the power supply to be temporarily
disconnected.
CO
mode –
the pump has been switched on.
CU
mode –
the pump has been switched
off.
The output power supply is disconnected,
waiting for the defect to be repaired; once
the defect is repaired, press any button.
CO
mode – the pump has been switched off.
CU
mode – the pump has been switched off;
waiting for the defect to be repaired
(replacement of a sensor); once the defect
has been repaired, press any button.
The pump is stopped; waiting for the defect
to be repaired (higher temperature).
NOTE:
The above alarms are signalized with an intermittent acoustic signal until
the relevant defect has been repaired or the controller has been switched
off. After the defect has been repaired, the controller starts normal
operation.
NOTE: In order to switch off the controller during an alarm,
press and hold both
the (-) and the (+) button for 2 seconds.