AURATON RPT 230 Скачать руководство пользователя страница 2

3

Successful pairing is indicated by the LED diode on the AURATON RPT repeater 
no longer blinking green and the repeater switching to normal operation.

In the event of a pairing error, steps 1 and 2 must be repeated. If more errors occur, 
all devices must be unpaired by RESETTING the AURATON RPT repeater (see "RESET 
- Unpairing all devices paired with the AURATON RPT repeater") and try pairing the 
devices again.

NOTE:

One AURATON RPT repeated can be paired to several LMS devices (max. 64).

Pairing of LMS devices
with the AURATON RPT repeater

1

.

Pairing  of  the  AURATON  RPT 

 

repeater  with  an 

LMS device (e.g. AURATON 2025 RTH or T-1 RTH 
thermostats) is initiated by pressing the left pairing 
button (green triangle - 

   

) on the AURATON RPT 

repeater and holding it for at least 2 s until the LED 
diode starts blinking green - then the button must 
be released.

 

The  AURATON  RPT  repeater  waits  for  pairing  for 

120  seconds.  After  this  period,  it  automatically 
returns to normal operation

.

2

.

When  the  LED  diode  on  the  repeater  blinks  green,  press  the  "pairing 

button"  on  the  device  to  be  paired  and  hold  it  for  at  least  2  seconds
(a detailed pairing instruction is supplied with each LMS device).

LED

NOTE

An  LMS  device  (e.g.  the  AURATON  2025  RHT  -  a  transmitter) 

must first be paired with a receiver (e.g. AURATON RTH) and 
only then with the AURATON RPT repeater.

(The detailed instruction for pairing transmitters to receivers is 

supplied with each device separately.)

Pairing of an LMS device to several repeaters 
"chain" operation

It is possible to build chains consisting of up to 8 repeaters.

In such a case, the LMS device (e.g. AURATON 2025 RTH) must be 
paired to only the nearest AURATON RPT repeater. 

Every other AURATON RPT repeater automatically receives the signal 
from the previous repeater and forwards it without any additional 
user settings.

AURATON RTH

AURATON RPT

Repeater

AURATON RPT

Repeater

max. 8 pcs

AURATON RPT

Unpairing devices from the AURATON RPT 
repeater

1

.

Unpairing  of  a  device  from  the  AURATON 

RPT  repeater  is  initiated  by  pressing  the 
right  unpairing  button  (red  triangle  -

   

  ) 

on the repeater and holding it for at least 2 
seconds until the LED diode starts blinking 
red - then the button must be released.

The repeater waits to be unpaired for 120 

seconds. After this period, it automatically 
returns to normal operation.

LED

2

.

When the LED diode of the AURATON RPT repeater blinks red, press the 

"pairing button" on the device to be unpaired and hold it for at least 2 
seconds (a detailed unpairing instruction is supplied with each LMS device).

3

.

Successful unpairing is indicated by the LED diode no longer blinking red 

and the repeater switching to normal operation. 
In the event of an error, steps 1 and 2 must be repeated.

Receiver

To fasten the AURATON RPT  to the wall:

1)

  Remove protective covers from the lower and upper part of the regulator. 

2)

  On the wall, mark the location of holes for fastening screws.

3) 

In marked places, drill holes of a diameter corresponding to the bundled 
wall plugs (5 mm).

4)

  Insert wall plugs into the drilled holes.

5)

  Screw in the RPT repeater to the wall with screws, making sure they hold the 

receiver securely.

Fastening the RPT reapeater to the wall

NOTE

:  If the wall is wooden, there is no need to use wall plugs. In such a case, 

drill  two  holes  2.7  mm  in  diameter  instead  of  5  mm,  and  screw 
the screws directly into the wood.

hole for fastening 

the receiver to the wall with a screw

NOTE

:

The

  RPT

  repeater  cannot  be  placed  in  metal  containers    (e.g.  an 

assembly box, a metal enclosure of a heater) in order to not to interfere 
with its operation.