AURATON RPT 230 Скачать руководство пользователя страница 1

RPT 230 / RPT 12

R E P E A T E R

User Manual

The AURATON RPT repeated is a device that repeats the signal emitted by a 
transmitter to the receiver, without any modification of the signal, in order to 
increase the range of the transmitter's radio transmission range.

This is done, 

for example, in manufacturing buildings where the receiver is out 

of the transmitter's range or in multi-floor buildings where thick walls hinder 
transmission between the transmitter and the receiver.

Principles of operation of the AURATON RPT

AURATON RTH

Receiver

Transmitter

max. 30m

(indoor)

AURATON RTH

Receiver

Transmitter

max. 30m

(indoor)

AURATON RPT

max. 30m

(indoor)

Repeater

AURATON RPT

It is possible to build chains consisting of up to 8 repeaters. Each AURATON RPT 
repeater automatically receives the signal from another repeater and forwards 
it without any additional user settings.

AURATON RTH

AURATON RPT

Repeater

AURATON RPT

Repeater

max. 8 pcs

AURATON RPT

button for unpairing devices

button for pairing devices

with the repeater

diode indicating operation

of the device

cable fixture 

power supply connection terminal 

230 V AC or 12 V DC*

key

Green continuous light

 

– 

the repeater is waiting for a data packet

.

Green  blinking  light

 

– 

the  repeater  is  waiting  for  device  pairing

  - 

(

chapter: "Pairing of LMS devices with the AURATON RPT repeater"

).

Red blinking light

 

– 

the repeater is waiting for a device to unpair

 - 

(rozdział:  „

chapter:  "Unpairing

 

of  devices  from  the  AURATON  RPT 

repeater"

”).

Alternating  red  and  green  light  for  1-2  seconds

 

 

the  repeater 

receives/sends a data packet.

Alternating red and green light

ALARM - 

the repeater's connection with one of the paired devices is 

broken. If AURATON RPT does not receive a data packet from 

a paired device for 35 minutes, then it indicates this with 

alternating red and greed diode light.

 

RESET  -

the  repeater  unpairs  all  the  previously  paired  devices  - 

(chapter:  "RESET  -  Unpairing  all  devices  paired  with  the 

AURATON RPT repeater")

Key - description of diode signaling

hole for the screw fixing

the repeater to the wall

hole for the screw fixing

the repeater to the wall

Description of the AURATON RPT 230/12
repeater

IN
OUT

ALARM

RESET
ALARM

35

RX/TX

min

IN

OUT

ALARM

RESET

35

min

1

Take  off  protective  covers  from  the 
lower and upper part of the 

AURATON 

RPT

 .

AURA

TON RPT

Fastening the AURATON RPT repeater.

protective cover

NOTE:

When  installing  the  AURATON  RPT  repeater  its  power 

supply  must  be  disconnected.  It  is  recommended  that 
the installation is performed by a qualified specialist.

NOTE:

The  permanent  electrical  system  of  a  building  must 

include a breaker and an overcurrent protection.

2

3

.

4

.

Take off cable tie clamps from the lower 
and upper part of the 

AURATON RPT

.

Connect power supply conductors to the 

power  supply  terminals

  of  the 

AURATON RPT

, observing safety rules

After  connecting  the  conductors,  they 
must  be  secured  with  the  cable  tie 
clamps and reinstall protective covers of 
the 

AURATON RPT

 .

ALARM

35

min

AURATON RPT 230

cable tie clamp

AURATON RPT 230

ALARM

35

min

RX/TX

~230 VAC

 

(AURATON RPT 230)

  

12 VDC

 

(AURATON RPT 12)

*

Receiver

Отзывы: