background image

Rev. A 07/10 

AMMF16R

 

 

WARNING:

 

To reduce the risk of fire, electric shock, or injury:

 

1.    Make sure that the power source complies with the electrical requirements of the misting fan. 

2.    Do not use this misting fan with any solid state speed control device.         

3.    Do not expose to rain. Store indoors. 

4.    Do not use this misting fan with a damage filter or without a filter installed. 

5.    To reduce the risk of personal injury, the misting fan should not be use as a toy or placed where         

children can reach it.   

6.    Close supervision is necessary when any appliance is used near children. 

7.    Use this misting fan only as described in this manual.    Any other use may cause electrical shock,     

fire, injury to people or animals. 

 

WARNING:

 DO  NOT  USE THE MISTING ON-OFF SWITCHES AS THE MEANS 

OF  DISCONNECTING  POWER  WHEN  INSTALLING  OR  SERVICING  THIS  PRODUCT.   
ALWAYS DISCONNECT THE POWER CORD. 

8.  Disconnect the power cord before moving or performing any maintenance on the misting fan. 

9.    This misting fan shall not be used in potentially dangerous conditions, such as flammable, 

explosive or chemically loaded atmospheres. 

10.    Do not use or store near hazardous materials. 

11.    Completely assemble the misting fan according to these instructions before connecting to the 

power source.   

12.    If the misting fan is not working correctly, has missing parts, has been dropped or damaged, left 

outdoors or dropped in water, call an authorized service center for evaluation, adjustment or 

repair. 

WARNING:

 

IMPROPER CONNECTION OF THE EQUIPMENT-GROUNDING 

CONDUCTOR CAN RESULT IN A RISK OF ELECTRICAL SHOCK.    CHECK WITH A 
QUALIFIED ELECTRICIAN OR SERVICE PERSON IF YOU ARE IN DOUBT AS TO 
WHETHER THE OUTLET IS PROPERLY GROUNDED.    DO NOT MODIFY THE PLUG 
PROVIDED WITH THE MISTING FAN IF IT WILL NOT FIT THE OUTLET; HAVE A 
PROPER OUTLET INSTALLED BY A QUALIFIED ELECTRICIAN. DO NOT USE A 
THREE-PRONG TO TWO-PRONG ADAPTER. IMPROPER CONNECTION MAY CREATE 
A RISK FOR ELECTRICAL SHOCK. 

 

13.    This product employs overload protection (fuse). A blown fuse indicates an overload or   

short-circuit situation. If the fuse blows, unplug the product from the outlet. Replace the fuse 

per the user servicing instructions (follow product marking for proper fuse rating) and check the   

product. If the replacement fuse blows, a short-circuit may be present and the product should   

be discarded or returned to an authorized service facility for examination and/or repair.” 

14.    To protect against electrical shock, do not immerse unit, plug, or cord in water or spray with   

liquids. 

15.    Keep the cord away from heated surfaces. 

16.    To reduce the risk of injury from the misting fan accidentally starting, unplug the power cord   

before replacing the filter. 

17.    Do not leave the misting fan unattended when it is plugged in. Unplug it from the power outlet   

when not in use and before servicing. Turn off the misting fan before unplugging. 

Содержание AMMF16R

Страница 1: ...SE INSTRUCTIONS CAUTION Before using this product read this manual and follow all safety rules and operating instructions Failure to comply with instructions could result in personal injury and or property damage IMPORTANT For replacement parts or assembly questions call 1 800 320 6478 or go to www auramist net ...

Страница 2: ...misting fan before using Safety is a combination of common sense staying alert and knowing how this misting fan works Use this misting fan only as described in this manual To reduce the risk of personal injury or damage to the misting fan use only recommended accessories Understanding Safety Terminology DANGER If safety information is not followed someone will be seriously injured or killed WARNIN...

Страница 3: ...been dropped or damaged left outdoors or dropped in water call an authorized service center for evaluation adjustment or repair WARNING IMPROPER CONNECTION OF THE EQUIPMENT GROUNDING CONDUCTOR CAN RESULT IN A RISK OF ELECTRICAL SHOCK CHECK WITH A QUALIFIED ELECTRICIAN OR SERVICE PERSON IF YOU ARE IN DOUBT AS TO WHETHER THE OUTLET IS PROPERLY GROUNDED DO NOT MODIFY THE PLUG PROVIDED WITH THE MISTIN...

Страница 4: ... fan on a stable flat surface to avoid the chance of tipping 23 Never place the misting fan where it may fall into a water reservoir example bathtub or pool or anything containing an electrical conductive substance 24 When the product is used outdoors use only on GFCI Ground Fault Circuit Interrupter protected receptacles 25 This product must be grounded If it should malfunction or break down grou...

Страница 5: ...uard assembly 1 2 Rear fan guard 1 3 Rear fan guard nut screw on motor housing 1 4 Fan blade 1 5 Fan blade nut screw on motor axis 1 6 Power base assembly 1 7 Fan head assembly 1 8 Fan pole assembly 1 9 Fan pole screw 1 10 Screws 2 Carton Contents ...

Страница 6: ...an guard nut rotate counterclockwise and the misting fan blade nut rotate clockwise from the misting fan head assembly fig 4 7 Align the rear fan guard hole to the three pins on the motor housing and fasten the rear fan guard to the fan head assembly with the rear fan guard nut figure 5 8 Mount the fan blade to the fan motor shaft fig 6 Make sure the fan blade gap aligns with the pin clip on the m...

Страница 7: ...ALLY PLUGGED TO THE POWER OUTLET 2 Fan Operation ON OFF Speed control Press the button to Low Medium High or OFF to select fan speed fig 1 3 Fan Operation Oscillation Control To operate the oscillation function press down the oscillation switch To stop the oscillation function pull up the oscillation switch The oscillation angle is approximately 65 degrees fig 2 4 Misting Operation IMPORTANT This ...

Страница 8: ...4 Misting ON OFF control Mist ON Press the rocker switch to the ON position fig 5 Turn the ball valve to the ON position fig 6 Open the flow control valve until mist is visible then refer to ADJUSTING MIST DENSITY section to get an optimal mist performance fig 7 Mist OFF Turn the ball valve to OFF position fig 8 To prevent the accumulation of mineral deposits let the pump run for 2 minutes after c...

Страница 9: ...ockwise fig 11 5 Operating Tips For dry climates increasing the water flow will provide maximum cooling results In humid climates a reduced water flow is recommended CUSTOMER RESPONSIBILITIES Read and follow the maintenance schedule and the maintenance procedures listed in this section WARNING ALLWAYS UNPLUG THE POWER CORD BEFORE MOVING OR SERVICING THE MISTING FAN WARNING DO NOT IMMERSE THE MISTI...

Страница 10: ...filter from package and orient the directional arrow so that the flow direction is towards the left fig 3 Push the hose into the push in connector to connect the filters Reinstall filter cover FUSE REPLACEMENT WARNING ALLWAYS UNPLUG THE POWER CORD BEFORE REPLACE THE FUSE CAUTION This product employs overload protection fuse A blown fuse indicates an overload or short circuit situation If the fuse ...

Страница 11: ...ter faucet is OFF 2 Ball valve is OFF 3 Misting valve in the CLOSED position 4 Water filter needs to be replaced 1 Open the water faucet 2 Switch the ball valve to ON position 3 Open valve counterclockwise 4 Replace water filter Water streaming from nozzle 1 Air pump is not working 2 Air flow is lower 3 Air filter needs replacement 4 Air hose leaks 5 Foreign object in nozzle 1 Turn on the mist ON ...

Страница 12: ...Rev A 07 10 AMMF16R 12 Exploded View ...

Страница 13: ...er 1 11 FV9144 70 10 ball valve 1 12 ZF01MF A0 02 base plate asm 1 13 ZF01MF 30 00 pump vibrate resistant 4 14 WZQB01 00 00 air pump 1 15 ZF01MF 20 00 fan pole asm 1 16 ZF01MF A0 03 fan head asm 1 17 ZF01MF 10 03 rear guard grill 1 18 ZF01MF 10 22 rear grill nut 1 19 ZF01MF 10 02 fan blade 1 20 ZF01MF 10 21 blade nut 1 21 ZF01MF 10 01 front guard grill 1 22 TODQ56 05 01 5A fuse 1 23 FV9144 00 03 n...

Страница 14: ...r you Call the number below to get the nearest service center This warranty does not include the air or water filters which are expendable parts that can wear out from normal use within the warranty period This warranty applies for only 90 days if this product is ever used for commercial or rental purposes AuraMIST LLC 5210 Village Parkway Rogers AR 72758 The model number and manufacturing date co...

Отзывы: