![Aumuller PLS S12 24V DC Скачать руководство пользователя страница 13](http://html1.mh-extra.com/html/aumuller/pls-s12-24v-dc/pls-s12-24v-dc_assembly-and-commissioning-instructions_3016558013.webp)
13
Assembly Instruction
Spindle Drive PLS
D
ATA
SHEET
PLS50 S12 24V DC
D
ATA
SHEET
TECHNICAL DATA
U
N
Rated voltage
24V DC (19 V ... 28 V)
I
N
Rated current
3,0 A
I
A
Cut-off current
4,2 A
P
N
Rated power
72 W
DC
Duty cycle
5 cycles (ED 30 % - ON: 3 min. / OFF: 7 min.)
Protection rating
IP 54
Ambient temperature range
-5 °C ... +60 °C
F
Z
Pulling force max.
5000 N
F
A
Pushing force max.
s (mm)
F
(N)
1000
0
2000
3000
4000
5000
500
550
600
650
700
750
F
H
Pullout force
25000 N (fastening depended))
Spindle tube
Stainless steel
Connecting cable
non-halogen, grey 3 x 1,0 mm², ~ 3 m
v
Speed
4,0 mm/s
4,0 mm/s
s
Stroke
200 – 750 mm
L
Length
s + 600 mm (see order data)
Sound pressure level
70 dB (A)
B29VA
10
24
360
L
= s + 600 mm
Application: natural ventilation, SHEV, ferralux®-NSHEV
Internal Intelligent Control Electronics S12
Options
Programmable synchronised run (max. 4 drives) and special functions
M-COM for automatic synchronised run of multi drive systems and automatic sequence
control with FV locking drives (S3 / S12)
Spindle tube end with interior thread for clevis
Eyebolt and clevis for rear suspention
02
M12
Internal thread