Assembly Instruction
M-COM

®

 Click

 R

ESET

 / D

EMOUNTING

R

ESET

 

AND

 

REINITIALISATION

 

OF

  M-COM

®

 

Click

 

¢

To  reset  the  system:  press  the  pushbutton  within  the 

 

drilling 

  for  about  5  seconds  -  using  a  wire  (max. 

 

Ø 1mm). The supply voltage is applied. 

 

¢

The 

LED

 starts blinking 

red

 and lights after successful

 

reset permanently  

red

.

 

¢

The factory setting is reached, the learning process will 

 

automatically restart.

D

EMOUNTING

 

THE

 M-COM

®

 C

LICK

  

IN

 

CASE

 

EXCHANGING

 

A

 

FAULTY

 

DRIVE

In  case  of  exchange  a  faulty  drive,  demout  and  reset  the 

M-COM

®

 Click

.

 

¢

Switch 

off

 the supply voltage.

 

¢

Disconnect the connection cable from the faulty drive.

 

¢

Demount the faulty drive.

 

¢

Remove the 

M-COM

®

 Click

 

Œ

 

from the drive.

   Squeezing the 

locking hooks

 at the 

M-COM

®

 Click

 

Œ

 

 and  pulled  out  the 

M-COM

®

  Click

 

Œ

  from  the  drive

   - using the tongs 

Ž

.

 

¢

Mount the new / repaired drive and connect it.

 

¢

M-COM

®

 Click

 

Œ

 

in den Antrieb einstecken.

 

¢

Switch 

on

 the supply voltage - in 

CLOSE

 direction.

 

¢

Reset the 

M-COM

®

 Click 

(see chapter „Reset and re-

 

initialisation of 

M-COM

®

 Click

)“.

 

¢

Disposing  of  faulty  equipment  according  to  the  instal-

 

lation instructions of drives.

D

RIVE

N

OTE

The  tongs 

Ž

  is  included  in  the  scope  of

delivery of 

M-COM

®

 Click

.

  1

  3

squeeze both 

locking hook

3

LED display

Display

State

          0,5s - 0,5s

blinks 

red

 (6 times)

M-COM

®

 Click

 is waiting.

          continuous

lights

 red 

M-COM

®

 Click

 is reset

(Factory settings).

D

RIVE

M-COM

®

 Click

1

  4

wire 

max. ø1 mm

14 mm immersion depth