Assembly Instruction
M-COM
®
Click
R
ESET
/ D
EMOUNTING
R
ESET
AND
REINITIALISATION
OF
M-COM
®
Click
¢
To reset the system: press the pushbutton within the
drilling
•
for about 5 seconds - using a wire (max.
Ø 1mm). The supply voltage is applied.
¢
The
LED
starts blinking
red
and lights after successful
reset permanently
red
.
¢
The factory setting is reached, the learning process will
automatically restart.
D
EMOUNTING
THE
M-COM
®
C
LICK
IN
CASE
EXCHANGING
A
FAULTY
DRIVE
In case of exchange a faulty drive, demout and reset the
M-COM
®
Click
.
¢
Switch
off
the supply voltage.
¢
Disconnect the connection cable from the faulty drive.
¢
Demount the faulty drive.
¢
Remove the
M-COM
®
Click
Œ
from the drive.
Squeezing the
locking hooks
at the
M-COM
®
Click
Œ
and pulled out the
M-COM
®
Click
Œ
from the drive
- using the tongs
Ž
.
¢
Mount the new / repaired drive and connect it.
¢
M-COM
®
Click
Œ
in den Antrieb einstecken.
¢
Switch
on
the supply voltage - in
CLOSE
direction.
¢
Reset the
M-COM
®
Click
(see chapter „Reset and re-
initialisation of
M-COM
®
Click
)“.
¢
Disposing of faulty equipment according to the instal-
lation instructions of drives.
D
RIVE
N
OTE
The tongs
Ž
is included in the scope of
delivery of
M-COM
®
Click
.
1
3
squeeze both
locking hook
3
LED display
Display
State
0,5s - 0,5s
blinks
red
(6 times)
M-COM
®
Click
is waiting.
continuous
lights
red
M-COM
®
Click
is reset
(Factory settings).
D
RIVE
M-COM
®
Click
1
4
wire
max. ø1 mm
14 mm immersion depth