No.

Designation

Type

001.0

Housing

Sub-assembly

002.0

Bearing flange

Sub-assembly

003.0

Hollow shaft without worm wheel

Sub-assembly

005.0

Worm shaft

Sub-assembly

005.1

Motor coupling

005.2

Coupling pin

005.3

Manual drive coupling

005.4

Pull rope

006.0

Worm wheel

009.0

Planetary gear for manual drive

Sub-assembly

010.0

Retaining flange

Sub-assembly

017.0

Torque lever

Sub-assembly

018.0

Gear segment

019.0

Crown wheel

Sub-assembly

020.0

Swing lever

Sub-assembly

022.0

Drive pinion II for torque switching

Sub-assembly

023.0

Output drive wheel for limit switching

Sub-assembly

024.0

Intermediate wheel for limit switching

Sub-assembly

025.0

Locking plate

Sub-assembly

058.0

Wire for protective earth

Sub-assembly

061.0

Torque switching head

Sub-assembly

070.0

Motor

Sub-assembly

079.0

Planetary gear for motor drive

(SAN/SARN 07.1 – 14.1 for VDN

motor)

Sub-assembly

080.0

Planetary gear for motor drive

(SAN/SARN 16.1 for ADN90 motor)

Sub-assembly

155.0

Reduction gearing

Sub-assembly

500.0

Cover for switch compartment

Sub-assembly

501.0

Socket carrier (complete with sockets)

Sub-assembly

502.0

Pin carrier without pins

Sub-assembly

503.0

Socket for controls

Sub-assembly

504.0

Socket for motor

Sub-assembly

505.0

Pin for controls

Sub-assembly

506.0

Pin for motor

Sub-assembly

507.0

Plug cover

Sub-assembly

511.0

Screw plug

Sub-assembly

514.0

Output drive form A (without stem nut)

Sub-assembly

514.1

Axial needle roller bearing

Sub-assembly

535.1

Snap ring

539.0

Screw plug

542.0

Handwheel with ball handle

Sub-assembly

549.1

Output drive B3/B4/E

Sub-assembly

551.1

Parallel key

553.0

Mechanical position indicator

Sub-assembly

554.0

Socket carrier with motor cable

harness

Sub-assembly

No.

Designation

Type

556.0

Potentiometer for position transmitter

Sub-assembly

556.1

Potentiometer without slip clutch

Sub-assembly

557.0

Heater

Sub-assembly

558.0

Blinker transmitter including pint at

wires not qualified for nuclear

application (without impulse disc and

insulation plate)

Sub-assembly

559.0

Control unit without torque switching

heads and switches

Sub-assembly

566.0

Position transmitter RWG (not

qualified for nuclear application)

Sub-assembly

566.1

Potentiometer for RWG without slip clutch

Sub-assembly

566.2

Electronic board RWG

Sub-assembly

566.3

Wire harness for RWG

Sub-assembly

567.1

Slip clutch for potentiometer

Sub-assembly

568.1

Stem protection tube (without cap)

568.2

Cap for stem protection tube

568.3

V-seal

569.0

Change-over lever assy

Sub-assembly

569.1

Change-over lever

569.2

Notched pin

574.1

Radial seal output drive A for ISO

flange

575.1

Stem nut (without thread)

579.0

Switch for limit/torque switching

(including pins at wires)

Sub-assembly

580.1

Spacer

581.0

Stud bolt for switches

Sub-assembly

S1

Seal kit, small

Set

S2

Seal kit, large

Set

Содержание SAN 07.1

Страница 1: ...Electric multi turn actuators Operation instructions for valve automation in nuclear power plants SAN 07 1 SAN 25 1 SARN 07 1 SARN 25 1...

Страница 2: ...sizes SAN SARN 25 1 12 7 3 Delay time 12 7 4 Motor protection 12 7 5 Remote position transmitter 12 7 6 Limit and torque switches 13 7 7 Fitting the cover 13 8 Opening the switch compartment 14 8 1 R...

Страница 3: ...ection IP 68 24 18 Maintenance 24 19 Lubrication 25 20 Disposal and recycling 25 21 Service and training 25 22 Spare parts list Multi turn actuator SAN SARN 07 1 SAN SARN 16 1 with plug socket connect...

Страница 4: ...nsport proper storage mounting and installation as well as careful commissioning are essential to ensure a trouble free and safe operation During operation the multi turn actuator warms up and surface...

Страница 5: ...1 16 1 AUMA plug socket connector with screw type connection SAN SARN 25 1 Control connections on AUMA plug socket connector motor connection via terminals Threads for cable glands Standard Metric thr...

Страница 6: ...ves Electromagnetic Compatibility EMC 2004 108 EC Low Voltage Directive 2006 95 EC Machinery Directive 2006 42 EC Reference documents Product description Electric multi turn actuators SAN SARN Dimensi...

Страница 7: ...re handwheel using the circlip supplied 4 2 Storage Store in well ventilated dry room Protect against floor dampness by storage on a shelf or on a wooden pallet Cover to protect against dust and dirt...

Страница 8: ...sually according to ISO 5210 For output drive type A figure B 1 the internal thread of the stem nut must match the thread of the valve stem If not ordered explicitly with thread the stem nut is unbore...

Страница 9: ...ring until it is firm against the shoulder Press Lithium soap EP multi purpose grease on mineral oil base into the grease nipple with a grease gun for quantities please refer to table Protection tube...

Страница 10: ...an extension Excessive force may damage the change over mechanism Release change over lever should snap back into initial position by spring action figure D if necessary push it back manually Operatin...

Страница 11: ...ble it can be obtained from AUMA state commission no refer to name plate or downloaded directly from the Internet www auma com A special parking frame figure G 2 is available to protect against touchi...

Страница 12: ...n are considered We recommend to switch off the corresponding contactor directly by the limit or torque switch 7 4 Motor protection In order to protect against overheating and impermissibly high tempe...

Страница 13: ...Apply a thin film of non acidic grease e g petroleum jelly to the sealing faces Replace plug cover 50 0 and fasten bolts 50 01 evenly crosswise Fasten cable glands with the specified torque to ensure...

Страница 14: ...d supervision of such an electrician and in accordance with the applicable electrical engineering rules 8 1 Removing the cover from the switch compartment Remove 4 bolts and take off the cover at the...

Страница 15: ...ection Turn handwheel counterclockwise until valve is open then turn back by approximately a turn Press down and turn setting spindle D figure K 1 with screw driver in direction of arrow thereby obser...

Страница 16: ...lve to desired intermediate position Press down and turn setting spindle K figure K 2 with screw driver in direction of arrow thereby observe pointer L While a ratchet click is felt and heard the poin...

Страница 17: ...ts as overload protection over full travel also when stopping in the end positions by limit switching 11 2 Checking the torque switches The red test buttons T and P figure K 2 are used for manual oper...

Страница 18: ...test run 12 2 Check limit switching Move actuator manually into both end positions of the valve Check whether limit switching is set correctly Hereby observe that the appropriate switch is tripped in...

Страница 19: ...the ratio of the reduction gearings for the position transmitter the complete resistance range is not always utilized for the whole travel Therefore an external possibility for adjustment setting pot...

Страница 20: ...ry The position transmitter board figure P 1 is located under the cover plate figure P 2 20 Multi turn actuators SAN 07 1 SAN 25 1 SARN 07 1 SARN 25 1 for valve automation in nuclear power plants Oper...

Страница 21: ...ntil output current starts to increase Turn potentiometer 0 back until the following value is reached for 3 or 4 wire system approx 0 1 mA for 2 wire system approx 4 1 mA This ensures that the signal...

Страница 22: ...ncrease Turn back potentiometer 0 until a residual current of approx 0 1 mA is reached Move valve to end position OPEN Set potentiometer max to end value 16 mA Move valve to end position CLOSED Set po...

Страница 23: ...gearing was installed in our works If the turns per stroke are changed at a later date the reduction gearing may have to be exchanged too 16 Closing the switch compartment Clean sealing faces of housi...

Страница 24: ...cable glands must be suitable for the outside diameter of the cables refer to recommendations of the cable gland manufacturers As standard actuators and controls are delivered without cable glands Fo...

Страница 25: ...nd recycling AUMA actuators have an extremely long lifetime However they have to be replaced at one point in time The actuators have a modular design and may therefore easily be disassembled separated...

Страница 26: ...actuators SAN 07 1 SAN 25 1 SARN 07 1 SARN 25 1 for valve automation in nuclear power plants Operation instructions Sample name plate Actuator type Commission number Works number Enclosure protection...

Страница 27: ...sockets Sub assembly 502 0 Pin carrier without pins Sub assembly 503 0 Socket for controls Sub assembly 504 0 Socket for motor Sub assembly 505 0 Pin for controls Sub assembly 506 0 Pin for motor Sub...

Страница 28: ...1 SAN 25 1 SARN 07 1 SARN 25 1 for valve automation in nuclear power plants Operation instructions Actuator type Commission number Works number Enclosure prot output speed Torque range in CLOSED OPEN...

Страница 29: ...mbly 2 59 Planetary gear for motor drive Sub assembly 3 Drive shaft assy Sub assembly 3 05 Dowel pin 3 11 Pull rope Sub assembly 3 6 Worm wheel Sub assembly 3 7 Motor coupling 3 8 Manual drive couplin...

Страница 30: ...24 Declaration of Incorporation and EC Declaration of Conformity 30 Multi turn actuators SAN 07 1 SAN 25 1 SARN 07 1 SARN 25 1 for valve automation in nuclear power plants Operation instructions...

Страница 31: ...nce 4 Manual operation 10 Mechanical position indicator 23 Motor protection 12 Mounting to valve gearbox 8 N Noise level 6 Number of starts 6 O Output drive types 8 P Packaging 7 Position indicator 23...

Страница 32: ...d information about AUMA products refer to the Internet www auma com Y000 574 003 en 1 1 AUMA Riester GmbH Co KG P O Box 1362 DE 79373 Muellheim Tel 49 7631 809 0 Fax 49 7631 809 1250 info auma com ww...

Отзывы: