TFS-Dialog 400 - Advanced Information V02 11/2020
38
Short reference
Configuration in configuration mode
Extended > Dialling the destination number
Extended > Door opener
Important:
If the switch-on time is prolonged, it is necessary to
change the relay dead time of the door opener relay (applies to
COMpact 4000, 5000/R, 5200/R, 5500/R and COMmander 6000/R/RX
PBXs from firmware version 6.4A – see Advanced Information relating
to the PBX). The connected door opener must support switch-on time
configuration.
Note:
The character string of the door opener function must differ
from that of the light function.
Name/default
Function
Value x
Pause between picking up or
hanging up / 0.5 s
54x
1
(x 0.5 = 0.5 s), ...,
9
(x 0.5 = 4.5 s)
Name/default
Function
Value x
Character string for opening the
door via internal telephones /
(#)8
26x...#
0–9
(character string
with 1 to 6 digits)
Switching time door opener
relay / 2 s
56x
1
(x 0.5 = 0.5 s), ...,
9
(x 0.5 = 4.5 s)