Configuring and Operating Functions
Automatic Call Acceptance
Configuring and Operating Function Key for Automatic Call Acceptance
Automatic Call Acceptance
Automatic call acceptance facilitates headset operation at call centers or on hotlines. An
incoming call is automatically accepted after a configured amount of time. Call acceptance is
signalled by an attention tone.
Configuring and Operating Function Key for Automatic Call Acceptance
Press the key to switch the automatic call acceptance function on or off or to switch it over.
In addition, when functions are defined on the first key level, the status of the function is
indicated by the corresponding LED.
The configuration can be carried out as follows:
• Via COMfortel Set
Configuring Function Key for Automatic Call Acceptance via COMfortel Set
Requirements:
– An open configuration and the required PIN, if necessary
1.
Open the page Function keys > Assign function keys.
2.
Click one of the following tabs:
3.
Right-click the function key you want to assign.
A function selection dialogue opens.
4.
Select the Automatic call acceptance function.
LED signalling next to the key:
Green
Automatic call acceptance is enabled.
Off
Automatic call acceptance is disabled.
Level 1: Keys are defined on the first key level.
Level 2: Keys are defined on the second key level.