DIMENSIONS: (mm)

www.audixusa.com Call: 503-682-6933 Fax: 503-682-7114 

Audix Corporation 9400 SW Barber Street, Wilsonville, OR 97070

SERVICE AND WARRANTY:

This  product  is  under  warranty  for 

a  period  of  3  years  from  any  and  all 

manufacturing  defects.  Should  your 

microphone  fail  in  any  way,  please 

contact the Audix Service department at 

503-682-6933. A  Return Authorization 

number  is  required  before  returning 

any products

.

CARE AND MAINTENANCE:

The  MicroPod™  is  manufactured  to  exacting 

specs with roadworthy construction. However, 

the capsule is highly sensitive and should be 

handled with care. Avoid extreme temperatures 

and  be  sure  to  store  your  microphone  in  the 

pouch provided when not in use. Moisture of 

any  kind  can  adversely  affect  the  sound  and 

performance of your microphone. 

***All specifications subject to change without notice.

To register your 

microphone, please visit 

www.audixusa.com

SPECIFICATIONS:

FREQUENCY / POLARS:

Cardioid

Hypercardioid

ARCHITECTS AND ENGINEERS SPECIFICATIONS: 

The  microphone  system  shall  consist  of  a  condenser  type  with  a  modular  threaded  capsule 

and a variety of gooseneck attachments. The microphone shall be available in a cardioid and 

hypercardioid polar pattern and shall have a base terminating in a miniature male XLR. The 

gooseneck shall terminate in a miniature female XLR at the microphone end and shall have a base 

terminating in a male XLR plug. The microphone shall operate on 18-52 Volts phantom power. 

The microphone shall have a sensitivity of 10 mV/ Pa and a nominal impedance of 150 ohms at 

1 kHz. The microphone shall have a maximum SPL level of ≥150 dB and shall be machined from 

brass with gooseneck fabricated from aluminum tubing, brass fittings, and coiled steel gooseneck 

material. The microphone be 12 mm in diameter and the gooseneck available in 6 inch, 12 inch, 

and 18 inch length. The microphone system shall be called the MicroPod™ Series.  

OPERATION AND MAINTENANCE: 

The  MicroPod™ Series are low impedance microphones and should be plugged into a “mic level” 

input on your console, mixer or recording device. The MicroPod microphones require phantom 

power and will NOT operate without phantom power voltage (minimum of 18-52 Volts) which is 

available on most professional mic preamps and mixing devices. Avoid plugging or unplugging 

the microphone from a PA system unless the channel is muted or the volume of the system turned 

down. Failure to do so may result in a loud “popping” noise which could seriously damage the 

speakers in the PA system. 

Changing Capsules:

 Capsules can easily be interchanged by simply screwing them on and off 

the capsule housing.

Permanent Installation:

 The MicroPod™can be conveniently plugged into any standard XLR 

female connector or receptacle. For permanent installation onto a table, podium or flat surface, 

use the supplied flange shockmount. The base of the MicroPod™ fits securely into the flange and 

a standard XLRf microphone cable or panel jack may be used. If further shockmount or isolation 

is required, it is recommended to use the optional SMT1218R rubber shockmount which requires 

boring out a 2 inch hole. 

USER TIPS: 

Speaking distance and angle of microphone: The two flexible portions of the microphone will 

enable you to position the mic according to height and speaking style of the user. In general, the 

microphone can be angled at 60-75 degrees towards the speaker and be 12-16 inches away from 

the mouth. A shorter distance can be used for a fuller sound or for weaker voices. 

Windscreen: The supplied windscreen should be used to help minimize pop noise and breath 

noise.  If  breath  or  pop  noise  appears  to  be  excessive,  either  move  further  away  from  the 

microphone or try speaker over the top of the microphone rather than directly into it. To further 

control excessive pop or breath noise, the optional WS1281 is suggested. 

Using with ATS-10 Table Stand: For ultimate flexibility and portability, the optional ATS-10 heavy 

duty table stand is ideal. Since the electronics for the MicroPod™ is built right into the housing 

of the M1250B microphone, all that is necessary is to plug the mic directly into the table stand 

connector on the top of the base. The mic cable will be plugged into the back of the base and 

connected to a low impedance mic level input on the mixer or recording device. Remember that 

phantom power is required in order to operate. There is a noiseless 2 position on-off switch 

located in the table stand. The down position is ‘on’ and the up position is ‘off’. The LED indicator 

light will be lit when the mic is turned on. This is not a push-to-talk system so you need not hold 

down the switch, just push and click to on or off position. A standard XLR-XLR microphone cable 

can be used to connect the ATS-10 to the mixer or recording device. 

To use on microphone stand: The MicroPod ™ may be used on any standard microphone stand 

by using the DClip. The XLR base of the microphone will snap securely into the DClip and can 

be used at any angle. 

Transducer Type   

 

           Condenser 

Frequency Response        

        50 Hz  - 19 kHz 

Polar Pattern        

 

             Cardioid   

                  

                        

        Hypercardioid

Output Impedance                    

             150 ohms 

Sensitivity                                                10 mV / Pa (C) @ 1k

                                                                10 mV / Pa (HC) @ 1k

                                                                 11 mV / Pa (O) @ 1k

Signal/Noise Ratio   (A-weighted)                    73 dB 

Equivalent Noise Level (A-weighted)               21 dB

Maximum SPL @ .5% THD                             ≥140 dB 

Dynamic Range                                                119 dB 

Power Requirements                                   18 – 52 V

Connector 

                                        3 pin XLRm  

Polarity                                                 Positive pressure on 

 

                                              diaphragm produces  

 

 

                            positive voltage on pin

 

 

                                    2 relative to pin 3 

Housing / Finish                                       Machined brass /

                                                                   Powder coat  

Weight  of M1250                                  20 grams / 0.7 oz 

Length of M1250                                 54 mm / 2.1 inches 

 

Length of Goosenecks           157.5 mm / 373 mm / 430 mm

 

 

 

6 inches / 12 inches / 18 inches

 

 

 

 