Installed Sound
Mic Input connector:
3 pin XLRF-type
Base Output connector: 5 pin Phoenix Terminal* (ATS1LP)
5 pin XLRm** (ATS1LX)
Switch:
Noise free mechanical
Off (mute) attenuation:
45 dB minimum
Phantom power requirements:
36 - 52 V DC, 2mA typical
Dimensions:
160 mm / 6.9 inches length
124 mm/ 5.9 inches width
45 mm / 1.8 inches height
Weight:
1.4kg / 3 lbs
Closure I/O voltage:
-0.5 V to 30 V
Closure through current:
200 mA
(resettable fuse protected)
On resistance:
> 10 Ohms
I/O leakage current :
1 uA
LED input:
Active when low (0.7 V DC),
TTL compatible
SPECIFICATIONS:
LOGIC CONNECTIONS:
SWITCH SETTINGS:
Setting Dip Switch - Low Cut Filter
Inside the base, locate the switch on the PCB labeled “Low Cut Filter” [Figure 6].
The filter (12dB, 2nd order) provides additional protection from bass frequencies
that may cause rumble, hum, or vibration by eliminating frequencies below 100 Hz.
To engage the filter, push the dip switch to the “on” position.
Setting Dip Switches - On, Off, Mute
Inside the base, locate the panel of 3 dip switches on the PCB [Figure 7]. The top
switch determines whether the control of the switch is handled externally by logic
or locally by the user. The default is “local”. The other two sets of switches control
the function of the lighted switch on the front of the base [Figure 7].
The options are:
1: “Momentary” hold to talk or hold to mute.
2: “Toggle” (also known as “latching”) push on and push off. There are 4 switch
function combinations as follows:
SWITCH FUNCTION (Local Mode) DIP SWITCH SETTING
1. Momentary Mute:
Mic is on;
switch is pressed and held to mute.
2. Momentary Talk:
Mic is off;
switch is pressed and held to talk.
3. Toggle Off:
Mic is on; switch is
pressed to turn the mic off and on
4.
Toggle On:
Mic is off; switch is
pressed to turn the mic on and off
SWITCH FUNCTION (External Mode)
By setting the dip switch (#3) to the “E” position, the switch functions can
be controlled remotely by an automated mixer. In this case, the function of
the switch on top of the base can be programmed by the installer for
custom applications.
E
L
3
2
1
E
L
3
2
1
E
L
3
2
1
E
L
3
2
1
FIGURE 6
Low Cut Filter Switch
Setting Dip Switches
FIGURE 7
* Recommended replacement Phoenix Terminal connector:
1803604 (MC 1.5/5-ST-3.81)
** Recommended XLRf mating connectors:
Switchcraft AAA5FBAUZ or Neutrik NC5FXX-B or equivalent
REGISTER YOUR PRODUCT ONLINE:
http://www.audixusa.com/registration
FROM YOUR PHONE:
SERVICE AND WARRANTY
Audix microphones are warranted against manufacturing
defects for a period of: 3 years for condenser microphones
and 5 years for dynamic microphones. Should your
microphone need repair, please contact Audix to obtain Return
Authorization number.
CARE AND MAINTENANCE
Audix microphones are manufactured to exacting specifications both for
durability and long term usage. The capsule, however, is a highly sensitive
element and should be handled with care by avoiding extreme temperatures
and moisture, which can adversely affect the sound and performance of
your microphone. When not in use, be sure to store your microphone in the
provided pouch.
www.audixusa.com
503-682-6933 Fax: 503-682-7114
Audix Corporation 9400 SW Barber St. Wilsonville, OR 97070