2a.

 

Ceiling installation: 

 
Install the Audipack ceiling mount to the structural ceiling.  
Refer to the installation manual of the ceiling mount to install correctly. 

Use ceiling mounts 390061 or 390065 (max. Load per piece 70 Kg). 
 

In a ceiling mounted situation, the thinner lid of the Silencer is mounted 
between the projector mount and tube set. 

 
Install the tube set, theninstall the pre-mounted projector mount with lid 

to the ceiling mount. 
 

2b. 

Ceiling lift installation: 

When the Silencer is installed to an Audipack ceiling lift, make sure the 
centre point of gravity of the product is in line with the ceiling lift.  

An unbalanced assembly will affect the function, and accuracy of the 
ceiling lift. 
 

Use all approriate mounting holes for installing the 
Silencer to the lift. 

Pleas note (when ordering) the way of use of the 
Silencer). 

Always use the P7010 mounting interface to connect 
the Silencer to a lift. 

 
 

3. 

Attach all needed projector cabling and guide the cable in a way that they 

do not obstruct airflow or closing the Silencer. For every model the cable 
management can change. 

 

4. 

The Silencer has a build-in hour-counter. This counter is essential to count 

the running hours of the ventilators. After a certain amount of hours the 
ventilators should be replced to ensure optimum ventilation.  

This is in advantage of the projector running hours. 
 

 
 

 
 

 
 

 
 

 

Содержание Silencer SMALL

Страница 1: ...User manual Silencers in general Copyright Audipack version 31 01 2010 ...

Страница 2: ...gned for Maximum surrounding temperature 10 25 Degrees Celcius Apropriate fresh air ventilation No direct contact of silencer sides top and bottom to ceiling or structural components of the building Only suitable for the determined projector brand and type No air flow obstruction at the air intake and output Provide clean air preventing over accessive air polution with dust chalk and other particl...

Страница 3: ...ed with a certain angle please contact Audipack for confirmation 5 degrees tilt is allowed Use appropriate mounting materials to install the Silencer According the choosen model the amount of mounting points can be different Use all mounting points available The installer must determine the correct mounting materials according the situation and total weight of the assembly ...

Страница 4: ...e product is in line with the ceiling lift An unbalanced assembly will affect the function and accuracy of the ceiling lift Use all approriate mounting holes for installing the Silencer to the lift Pleas note when ordering the way of use of the Silencer Always use the P7010 mounting interface to connect the Silencer to a lift 3 Attach all needed projector cabling and guide the cable in a way that ...

Страница 5: ...e all ventilators afther 10 000 running hours Install the Silencer electronically in a way that the ventilators are not running when the projector is not used Audipack contact data Audipack Instriestraat 2 2751 GT Moerkapelle The Netherlands 31785931671 Support audipack com Audipack audipack com ...

Отзывы: