AudioScience Hono CobraNet 16.0M Скачать руководство пользователя страница 1

22 August 2011 - PRELIMINARY 

 
www.audioscience.com 

22 August 2011 

 

C

OBRA

N

ET 

16.16D

 

 16X16 AES/EBU COBRANET

®

 INTERFACE 

 

1 DESCRIPTION 

The Hono CobraNet 16.16D is a CobraNet interface designed for use in the professional installed sound market. 
This device receives up to 16 channels of CobraNet and sends them to 16 AES/EBU (8 stereo) audio outputs, 
while simultaneously inputting 16 channels of AES/EBU (8 stereo) audio and transmits them up to 16 channels of 
CobraNet. 
 
The Hono CobraNet 16.16D has been purposely designed to compliment and fully integrate with all of today’s 
CobraNet compatible DSP products. In addition, this is the ideal solution for many situations where a project 
requires numerous channels of digital audio routed throughout a facility, but doesn’t require a dedicated DSP 
processor. 
 

2 FEATURES 

Inputs 

• 

Sixteen AES/EBU (8 stereo)  

• 

Sample Rate Converters 

• 

Pluggable terminal block connectors (Phoenix 
style) 

 

Outputs 

• 

Sixteen AES/EBU (8 stereo) 

• 

Sample Rate Converters  

• 

Pluggable terminal block connectors (Phoenix 
style) 

 

CobraNet 

• 

Redundant CobraNet 

• 

Sixteen channels of CobraNet in and out 

• 

Four CobraNet transmitters and eight receivers

 

DSP 

• 

Peak and RMS meters on all audio inputs and 
outputs 

• 

Mixing of any input to any output 

 

Power 

• 

Built-in 90-260VAC power supply 

 
Chassis 

• 

1U rack-mount unit 

• 

1 RU, 19”(482mm) W x 8”(203mm) L x 
1.75”(44mm) H 

 
Control 

• 

All settings adjustable from ASIControl software 

 

 

 

NO

Содержание Hono CobraNet 16.0M

Страница 1: ...cts In addition this is the ideal solution for many situations where a project requires numerous channels of digital audio routed throughout a facility but doesn t require a dedicated DSP processor 2...

Страница 2: ...I IEC 958 Professional Connector 3 81mm Terminal block Input Impedance 10K Ohms Dynamic Range 1 140dB any input to any output THD N 2 135dB any input to any output Sample Rate 32 44 1 48 and 96kHz Fr...

Страница 3: ...ES EBU Out 6 AES EBU Out 7 AES EBU Out 8 AES EBU Out 5 Hono CobraNet 16 16D AES EBU Out 4 Key Input Output Silence Detector Meter AES EBU 100Mbps Ethernet RJ 45 16 x 16 CobraNet Interface Mixing Matri...

Страница 4: ...PRELIMINARY HONO COBRANET 16 16D www audioscience com 4 22 August 2011 6 REVISIONS Date Description 22 August 2011 Preliminary...

Страница 5: ...ETHERNET CONNECTION 15 12 3 AC POWER 15 13 OPERATION 16 13 1 POWER UP SEQUENCE 16 13 1 1 AC Power 16 13 1 2 Firmware images 16 13 1 3 Firmware loading sequence 16 13 1 4 Loading the factory firmware i...

Страница 6: ...Meter 24 14 1 5 Setting AES EBU Clocking 25 14 1 6 Input and Output Volume Adjustment 29 14 1 7 ClockSourceIn 29 14 2 COBRANET CONFIGURATION 30 14 2 1 Setting Up AudioScience Software to Configure Co...

Страница 7: ...Adapter information seen in right side of ASIControl 23 Figure 12 Using ASIControl to select Line_Out 1 23 Figure 13 Level displayed by ASIControl for Line_Out 1 23 Figure 14 A stereo peak meter displ...

Страница 8: ...f the provided plug does not fit into your outlet consult an electrician for replacement of the obsolete outlet 10 Protect the power cord from being walked on or pinched particularly at plug ends conv...

Страница 9: ...accompanying the product CAUTION To reduce the risk of electric shock do not remove the cover No user serviceable parts inside WARNING 1 To prevent fire or electric shock do not expose this apparatus...

Страница 10: ...ed that the following conditions are met 1 Redistributions of source code must retain the above copyright notice this list of conditions and the following disclaimer 2 Redistributions in binary form m...

Страница 11: ...o CobraNet interfaces and any other compliant CobraNet device on the network The following table lists the Hono CobraNet Series and a description of each unit Model Network Protocol Description Hono C...

Страница 12: ...plain data The CobraNet term for an audio packet is bundle A bundle may contain from one to eight audio channels each channel being composed of PCM samples of 16 20 or 24 bits in length 11 2 CobraNet...

Страница 13: ...obaraNet_Ch 11 CobaraNet_Ch 12 CobaraNet_Ch 13 CobaraNet_Ch 14 CobaraNet_Ch 15 CobaraNet_Ch 16 CobaraNet_Ch 33 CobaraNet_Ch 34 CobaraNet_Ch 35 CobaraNet_Ch 36 CobaraNet_Ch 37 CobaraNet_Ch 38 CobaraNet...

Страница 14: ...n incomplete list of receiver routing variables follows rxBundle the number of the bundle to receive This should be the same bundle number being transmitted somewhere else on the network A value of 0...

Страница 15: ...e into the PRIMARY jack If a redundant network is being used then plug a second network cable into the SECONDARY jack See http cobranet info support design switched_networks for information on redunda...

Страница 16: ...e that is in place should a bad image be downloaded to the device The update image is the image that can be updated in the field if required 13 1 3 Firmware loading sequence When first powered up each...

Страница 17: ...Net audio connect A 1 pixel high bar indicates CobraNet audio connect but audio level is below 40 dBFS A 2 pixel high bar indicates CobraNet audio connect and an audio level greater that 40 dBFS but l...

Страница 18: ...Address Display This display shows the Hono CobraNet interface s network MAC address and IP address If the IP address has been assigned dynamically then DYNAM is displayed If has been assigned statica...

Страница 19: ...bar indicates the audio level is below 40 dBFS A 2 pixel high bar indicates an audio level greater that 40 dBFS but less than 35 dBFS Audio peak levels in the range of 40 dBFS to 20 dBFS are displayed...

Страница 20: ...the select button 1 Depress the select button After 1 second you will see RELEASE BUTTON TO SAVE CONTROL SETTINGS After about 3 seconds you will observe RELEASE BUTTON TO RESET CONTROL SETTINGS Releas...

Страница 21: ...th of these protocols require an IP address to be assigned to the unit 13 4 1 Network Mask Assignment The networking stack used for UDP messaging on each Hono CobraNet interface uses the following rul...

Страница 22: ...ere is more than one NIC in the PC upon startup ASIControl will first prompt the user for which network interface to use to communicate with CobraNet devices Next to invoke the CobraNet Object Tools C...

Страница 23: ...loading of the adapter s DSP in percent Note Utilization should be kept below 90 14 1 3 Level The levels in dBu for the adapter s line_outs and line_ins can be adjusted here In the example below the L...

Страница 24: ...ence devices return both RMS and peak level readings and ASIControl displays both simultaneously 14 1 4 1 Interface Figure 14 A stereo peak meter display RMS is green and peak is yellow To the right o...

Страница 25: ...no CobraNet interface AES EBU clocking for Module 1 Sample Rate Converter AES EBU Transmitter Sample Rate Converter AES EBU Transmitter Sample Rate Converter AES EBU Transmitter Sample Rate Converter...

Страница 26: ...48kHz CobraNet AES EBU Receiver BU AES EBU Receiver AES EBU Input 5 AES EBU Input 67 AES EBU Input 8 AES EBU Sync Input Sample Rate Converter Sample Rate Converter Sample Rate Converter Sample Rate Co...

Страница 27: ...e in the previous slot 2 A sample rate derived from any of the four AES EBU inputs on that module 32 44 1 48 64 88 2 or 96kHz 3 A sample rate derived from the AES EBU Sync input 32 44 1 48 64 88 2 or...

Страница 28: ...section outlines some common AES EBU clocking configurations 14 1 5 4 1 Everything running at 44 1 kHz local clock no sync required This is the default Hono CobraNet interface configuration There is n...

Страница 29: ...ane Below is an image of the first volume shown in the node pane The meter and level is found after the list of volumes the Hono CobraNet interface incorporates AudioScience s anything to anywhere mix...

Страница 30: ...ontrol from showing all CobraNet devices on a CobraNet network If all CobraNet devices are not showing in the top pane of ASIControl please check settings and or turn off any antivirus programs or fir...

Страница 31: ...l restart looking for all CobraNet devices on the network assigning IP addresses where needed and showing CobraNet devices on the network in its top pane 14 2 1 1 3 Connect CobraNet Device to the Netw...

Страница 32: ...n the other selections available The CobraNet Configuration dialog box opens Figure 23 ASIControl s Configure CobraNet 14 2 2 1 CobraNet Configuration Dialog Box There are three main sections of the d...

Страница 33: ...on so that the Hono CobraNet device will remember its CobraNet settings and IP address in the event of a power cycle If the persistence bit is left off bundle numbers sysName and sysLocation will be...

Страница 34: ...6 65279 for unicast 65280 65535 for private 1 8 Audio Channels The number of mapped channels from mixer to transmitter Channels 0 inactive and 1 32 can be assigned A 0 mapping of end channels shortens...

Страница 35: ...o 8 audio channels Bundle The basic CobraNet audio routing component assign a specific Bundle number here A Receiver can carry 0 channel will not be mapped to mixer to 8 audio channels 1 8 Audio Chann...

Страница 36: ...hem The OK button is clicked and the dialog box closes On the same CobraNet network is an ASI2416 Its CobraNet Configuration dialog box is opened using ASIControl Using the same procedures as above 25...

Страница 37: ...alog box 14 3 2 Configure Network Interface and Auto IP Assignment Range The network interface and the auto IP assignment range are grouped under Options Configure Network Interface and Auto IP Assign...

Отзывы: