audiophony Acute-08 Скачать руководство пользователя страница 3

ENGLISH

ACUTE - Active and passive speakers

Page 3

1 - Please read carefully :

We strongly recommend to read carefully and understand 
the safety instructions before attempting to operate this unit.

2 - Please keep this manual :

We strongly recommend to keep this manual with the unit for 
future reference.

3 - Operate carefully this product :

We strongly recommend to take into consideration every 
safety instruction.

4 - Follow the instructions:

Please carefully follow each safety instruction to avoid any 
physical harm or property damage.

5 - Avoid water and wet locations :

Do not use this product in rain, or near washbasins or other 
wet locations.

6 - Installation :

We strongly encourage you to only use a fixation system or 

support recommended by the manufacturer 
or supplied with this product. Carefully follow 
the installation instructions and use the 
adequate tools.
Always ensure this unit is firmly fixed to avoid 
vibration and slipping while operating as it may 

result in physical injury.

7 - Ceiling or wall installation :

Please contact your local dealer before attempting any ceiling 
or wall installation.

8 - Ventilation :

The cooling vents ensure a safe use of this product, 
and avoid any overheating risk.
Do not obstruct or cover these vents as it may 
result in overheating and potential physical injury or 
product damage. This product should never been 

operated in a closed non-ventilated area such as a flight case 
or a rack, unless cooling vents are provided for the purpose .

9 - Heat exposure :

Sustained contact or proximity with warm surfaces may cause 
overheating and product damages. Please keep this product 
away from any heat source such as a heaters, amplifiers, hot 
plates, etc...

10 - Electric power supply :

This product can only be operated according to 
a very specific voltage. These information are 
specified on the label located at the rear of the 
product.

11 - Power cords protection:

Power-supply cords should be routed so that they 
are not likely to be walked on or pinched by items 
placed upon or against them, paying particular 
attention to cords at lugs, convenience receptacles 
and the point where they exit from the fixture.

Instructions and recommendations

12 - Cleaning precautions :

Unplug the product before attempting any 
cleaning operation. This product should be 
cleaned only with accessories recommended by 
the manufacturer. Use a damp cloth to clean the 
surface. Do not wash this product.

13 - Long periods of non use :

Disconnect the unit’s main power during long periods of 
non use.

14 - Liquids or objects penetration :

Do not let any object penetrate this product as it 
may result in electric shock or fire.
Never spill any liquid on this product as it may 
infiltrate the electronic components and result in 
electric shock or fire.

15 - This product should be serviced when :

Please contact the qualified service personnel if :
- The power cord or the plug has been damaged.
- Objects have fallen or liquid has been spilled into 
the  appliance.
- The appliance has been exposed to rain or water.
- The product does not appear to operate normally.
- The product has been damaged.

16 - Inspection/maintenance :

Please do not attempt any inspection or 
maintenance by yourself. Refer all servicing to 
qualified personnel.

17 - Operating environment :

Ambient temperature and humidity: +5 - +35°C, 
relative humidity must be less than 85% (when 
cooling vents are not obstructed).
Do not operate this product in a non-ventilated, 
very humid or warm place.

Содержание Acute-08

Страница 1: ...USER GUIDE July 2010 Version 4 0...

Страница 2: ...ake any maintenance operation when it is switched on as it may result in electric shock This unit is intended for indoor use only Do not use it in a wet or extremely cold hot locations Failure to foll...

Страница 3: ...ay from any heat source such as a heaters amplifiers hot plates etc 10 Electric power supply This product can only be operated according to a very specific voltage These information are specified on t...

Страница 4: ...ials used ensure enough rigidity to eliminate parasitic noises Each speaker features rigging points to stack several speakers and baseplates to use speaker stands Even though they are incredibly good...

Страница 5: ...g Im pe da nc e SPL 1W 1m IN O UT PIN 1 PIN 1 FULL RANG E FULL RANG E OUTPUT AS S IGNMENT P IN 1 P IN 1 S IGNA L GR OUND LINK A LINK B INPUT A INPUT B Push To Re se t 220 240V 10A 50 60Hz O UTPUT A O...

Страница 6: ...ENGLISH ACUTE Active and passive speakers Page 6 3 4 Wiring active speakers ACUTE 08 AMP and ACUTE 10 AMP 3 5 Connecting a microphone to active speakers ACUTE 08 AMP and ACUTE 10 AMP...

Страница 7: ...ENGLISH ACUTE Active and passive speakers Page 7 3 5 Active speakers wiring ACUTE 12 AMP et ACUTE 15 AMP 3 6 Connecting a microphone to active speakers ACUTE 12 AMP and ACUTE 15 AMP...

Страница 8: ...the LINE IN signal only MIX Contient le mix entre LINE IN et MIC IN 7 POWER Switch Turns the amplification module ON OFF 8 Power input socket Use the supplied power cord to connect the unit to an elec...

Страница 9: ...n extra active speaker or amplifier This output combines together the signals of all inputs 8 Power input socket Use the supplied power cord to connect the unit to an electrical outlet 9 Fuse compartm...

Страница 10: ...akers Page 10 5 Dimensions 416 mm 238 mm 146 mm 615 mm 240 mm 356 mm 245 mm 5 2 ACUTE 12 and ACUTE 12 AMP ACUTE 15 and ACUTE 15 AMP 5 1 ACUTE 08 and ACUTE 08 AMP ACUTE 10 and ACUTE 10 AMP 475 mm 270 m...

Страница 11: ...esponse 45 Hz 3 kHz Sensitivity 1W 1M 94 dB Nominal impedance 4 Ohms Power handling 120 W Tweeter Membrane diameter 1 5 pouces 34 mm Membrane material Aluminium Frequency response 1 5 kHz 20 kHz Sensi...

Страница 12: ...quency range 10dB 60 Hz 20 kHz Impedance 8 Ohms Sensitivity 95 dB Power handling Program 300 W Power handling Max 1200 W SPL Max Peak 1 m 125 dB SPL Max long term 1 m 122 dB Cutoff frequency 2 kHz Hor...

Страница 13: ...er 300 W Tweeter Membrane diameter 1 75 44 5 mm Membrane material Titanium Frequency response 1 kHz 20 kHz Sensitivity 1W 1M 106 dB Nominal impedance 8 Ohms Power handling 50 W PHYSICAL CHARACTERISTIC...

Страница 14: ...Membrane diameter 1 75 44 5 mm Membrane material Titanium Frequency response 1 kHz 20 kHz Sensitivity 1W 1M 106 dB Nominal impedance 8 Ohms Power handling 50 W PHYSICAL CHARACTERISTICS Height 740 mm...

Страница 15: ...ENGLISH ACUTE Active and passive speakers Page 15...

Страница 16: ...ts to modifications without prior notice That is why technical specifications and the products physical configuration might differ from the illustrations Make sure you get the latest news and updates...

Отзывы: