User’s Guide and Warranty Information

PurePower 120 Volt models

Содержание PurePower 1050

Страница 1: ...User s Guide and Warranty Information PurePower 120 Volt models ...

Страница 2: ...ts Table of Contents About the PurePower APS 2 Safety Warnings 3 Installation Inspecting the Equipment 4 PurePower Preparation 5 Activating Up Your PurePower 8 Operation 12 PurePower Maintenance 13 Specifications 14 Troubleshooting 16 Service and Support 17 ...

Страница 3: ... and guard the integrity of your equipment In addition to pure power the Audiophile APS provides you with something unique in audio power regenerators protection against power outage The Audiophile APS maintains full wattage output even when the power fails completely Providing outstanding performance and reliability the PurePower s unique benefits include the following True double conversion AC r...

Страница 4: ...plug the input cord when the APS is turned on This removes the safety ground from the APS and the equipment connected to the APS To reduce the risk of fire or electric shock install this APS in a temperature and humidity con trolled indoor environment free of conductive contaminants Ambient temperature must not exceed 32 C 90 F Do not operate near water or excessive humidity 95 max To comply with ...

Страница 5: ...damage If any equipment has been damaged during shipment keep the shipping cartons and packing materials for the carrier or place of purchase and file a claim for shipping damage If you discover damage after acceptance file a claim for concealed damage To file a claim for shipping damage or concealed damage 1 File with the carrier within 15 days of receipt of the equipment 2 Send a copy of the dam...

Страница 6: ...r as a standalone cabinet If you are installing the APS in a rack follow the instruction in Rack Mount Setup Standalone shelf component When you position the APS horizontally on a shelf or in a non rack style AV equipment stand or enclosure ensure there is sufficient clearance for airflow through the grilles at front and rear of the unit Figure 1 Horizontal Cabinet Setup ...

Страница 7: ...06 Pure Power in Pure Sound out Installation ...

Страница 8: ... on a flat stable surface with the front of the APS facing toward you Attach the mounting handles to the bracket with the screws provided in the accessory kit Remove the screws attaching the front bezel from one side of the unit Align the rack mounting brackets with the screw holes on the side of the APS and replace screws Repeat for the opposite side If installing optional PowerPacks repeat Steps...

Страница 9: ...ctric space heaters with the APS Plug the APS power cord into a utility outlet All front panel indicators flash briefly and the APS conducts a self test When the self test is complete the indicator flashes indicating the APS is in standby mode If any other indicator flashes see troubleshooting page Start the APS by pressing the On button The indicator stops flashing and the bar graph indicators di...

Страница 10: ... quickly and firmly Plug the first PowerPack cable into the battery connector on the APS rear panel If additional PowerPacks are to be installed plug the cable of the second cabinet into the battery connector on the previous Powerpack NOTE The batteries charge to 80 capacity in approximately 2 hours However it is recommend ed that the batteries charge for 24 hours after installation or long term s...

Страница 11: ...ront panel displays the percentage of APS load capacity being used by your system see Figure The APS monitors and provides power to your system and charges the batteries as needed The LEDs do not illuminate when the APS load is less than approximately 10 Each LED represents a percentage of a full load rating If all of the bar graph indicators are illuminated and the red overload indicator flashes ...

Страница 12: ...PS shut down the APS automatically restarts Bypass Mode In the event of an extended APS overload or internal failure the APS transfers your system to utility power Battery mode is not available however the utility power continues to be passively filtered by the APS The bypass indicator illuminates when bypass mode is engaged The APS switches to Bypass mode when The APS has an overtemperature condi...

Страница 13: ...ower APS off To turn off the APS Press and hold the off button for approximately three seconds The APS switches to Standby mode and removes power from the APS output receptacles Unplug the APS from the power outlet the APS shuts down in five seconds All front panel indicators flash briefly prior to shutdown If you do not unplug the APS it remains in Standby mode NOTE Pressing the off button while ...

Страница 14: ...in approximately 2 hours However it is recommended that the batteries charge for 24 hours after long term storage When to Replace Batteries When the battery indicator illuminates the batteries may need replacing Conduct a self test If the battery indicator stays on contact Audiophile or your Audiophile dealer to order new batter ies The average battery life is aproximately 5 7 years The PurePower ...

Страница 15: ...l 700 700 34 15 3 5 x 17 x 19 5 PurePower APS Model 1050 1050 50 23 3 5 x 17 x 19 5 Electrical Input Nominal Voltage 120V Voltage Range 80 144V Frequency Range 45 65Hz 50 60 Hz auto sensing Noise filtering MOVs line filter for normal common mode noise Input Connections IEC 320 Input receptacle with supplied 6 power cord Electrical Outputs Output Voltage 120 VAC Voltage Regulation Nominal output vo...

Страница 16: ... interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guar antee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television ...

Страница 17: ... APS will continue to supply your components Battery indicator flashing Battery fully discharged Allow batteries to charge for 24 hours then hold alarm reset button for 3 secs for self test Battery failure Replace the batteries or contact your dealer Ground fault indicator flashing No ground wire or line Have the outlet wiring corrected or neutral reversed in wall Overtemp indicator flashing Inter...

Страница 18: ...Audiophile APS All PurePower APS models have a two year swap out warranty for original registered owners If we are unable to solve a problem with your APS over the phone we ll send you a replacement unit Just return the original in the same packaging with the supplied shipping documentation For technical support and warranty service Please contact Audiophile APS via email service audiophileAPS com...

Страница 19: ...Pure Power in Pure Sound out www audiophileaps com ...