The amplifiers will shut down automatically when no input signal is de-
tected for a user definable time (30 seconds up to 2 hours). 

To activate and setup this feature please refer to chapter "Programming". 

Due  to  security  concerns  the  "Auto-On"  feature  will  only  be  available 
after first manual switching on! 

 

 

While you are absent your AMP II G2 can switch on automatically and 
will  be  pre-heated  for  use  when  you  get  back.  To  activate  this  feature 
please use a 

long

 key press on the "

power

" button at the front. The display 

changes to show the countdown timer. A cursor will mark the number to 
be changed. A 

long 

key press will move the cursor one step to the right. 

Using a 

short

 key press you can change the desired number. Hours can be 

programmed in steps of one hour. Minutes can be programmed in steps of 
15  min.  The  following  diagram  explains  the  possible  countdown  timer 
settings: 

 

 

0

1 hour  15 min 

0

1

 hour  15 min 

01 hour 

15

 min 

1

1 hours 15 min 

0

2

 hours 15 min 

01 hour 

30

 min 

 

 

 

 

 

 

9

1 hours 15 min 

0

0

 hours 15 min 

01 hour 

00

 min 

 

 

 

10-hours-setting 

1-hour-setting 

Min-setting 

 

Legend: 

        long key press   

 

short key press 

 

Activate countdown by leaving the timer settings menu with a 

long

 key 

press. It will be activated automatically if you do not change any setting 
for longer than 10 seconds. 

 

If you want to use the countdown timer again it is activated by a single 
key  press.  Press  the  "

power

"  button  for  more  than  2  seconds  and  wait. 

After 10 seconds the previous set up countdown will start again. 

To deactive the countdown use a 

short

 key press at any time. 

 

"Warm Up" Countdown 

Содержание AMP II G2

Страница 1: ...audionet amP II G2 Mono Amplifier Owner s Manual...

Страница 2: ...for abso lutely natural music reproduction at highest user comfort embedding total system security Please read this manual before first use to make sure that you are able to use all provided function...

Страница 3: ...lt you local Audionet dealer The voltage specified at the rear of your AMP II G2 must match your mains specifications The AMP II G2 is a Class I unit and has to be earthed The correct polarization of...

Страница 4: ...our speakers to one pair of the gold plated output jacks of your AMP II G2 You may use pure wires or banana plugs Check the polarization of the speakers cables Usually the speaker jacks are labeled an...

Страница 5: ...in stand by mode you enter the corresponding menu by pressing the button at the front for longer than 2 seconds For a remote controlled switching on by your Audionet pre amplifier two simple optical T...

Страница 6: ...press you can change the desired number Hours can be programmed in steps of one hour Minutes can be programmed in steps of 15 min The following diagram explains the possible countdown timer settings 0...

Страница 7: ...y will report in clear every de tected error Overload Shorted loudspeaker cables or defective loudspeaker your AMP II G2 is capable of driving even 1W loads Temp Failure Do not cover the ventilation s...

Страница 8: ...nput Auto On threshold for level controlled automatic power on see above Auto Off time to automatic power down see above Choose between two texts to be displayed in stand by mode To change settings us...

Страница 9: ...er power off automatically OFF IN 30 SECS OFF IN 5 MIN OFF IN 15 MIN OFF IN 60 MIN OFF IN 120 MIN When the music stops wait for the specified time until automatic power down SET OFF TEXT AUDIONET Sele...

Страница 10: ...oduct of the succeeding dual stage differential voltage amplifier exceeds 1 GHz Input and output sections are decoupled using bootstrapped emitter followers The output section is equipped with power M...

Страница 11: ...t in a dry room at a reasonable room temperature Avoid moisture or any liquid to get into the unit Set up the unit in a free position so that the air is allowed to flow through the unit slits Do not c...

Страница 12: ...k3 typ 140dB at 25W 4W Noise 110dB at 10Veff Inputs Cinch WBT gold plated 37kW 220pF XLR Neutrik gold plated 3kW 170pF 1 GND 2 Pos 3 Neg Output 2 pair of gold plated WBT terminals Mains 220 240 Volt...