Type

Vented T-ligned - Passive/Active

Nominal 
Impedance

Passive: 8

Power handling 
RMS / Peak

Passive: 900W RMS / 1800W Peak 
Active: 1225W RMS / 2450W Peak

Frequency range 
@-3dBspl

Passive: 45 Hz - 1,0 kHz 
Active: 40 Hz - 100 Hz (extended preset)

Sensitivity spl 2

π

sr

102 dB

SPL@ Peak power

Passive: 134,5 dB 
Active: 136 dB / 138 dB

Components

18" LF Faitalpro Custom made, 4" Voice coil

Line Connectors

Active: Balanced 1 x IN, 1 x OUT Neutrik© XLR

Front connection 
for Cardio

Active: powerCON and XLR IN OUT 
Passive: speakON 4 or speakON 8 IN OUT

HP Connectors

Passive: 2x Neutrik© speakON linked

Construction

Birch marine Plywood 15 & 24 mm

Finish

High resistant Polyurea coating

Dimensions (h x w 
x d)

510 x 650 x 560 mm 
20,07’’ x 25,59’’ x 22,04’’

Weight

Passive: 39 kg / 86 lb 
Active: 40 kg / 88 lb

Mounting 
accessoiries

M20 screw & 35 mm compatible flange

Page 

 sur 

19

21

AUDIOFOCUS S series

USER’S MANUAL

Содержание S series

Страница 1: ...AUDIOFOCUS S series USER S MANUAL V1 0 Page sur 1 21 AUDIOFOCUS S series USER S MANUAL ...

Страница 2: ...Page sur 2 21 AUDIOFOCUS S series USER S MANUAL ...

Страница 3: ...S serie subwoofer 3 3 LOW END 3 4 HARDWARE AND COVER 4 SETUP 4 1 VOLUME 4 2 PRESET SELECTION S15 S18 4 3 DELAY S15 S18 4 4 S21 LED DISPLAY 4 5 S21 Preset 4 6 EASE PREDICTION 4 7 WIRING 4 8 ETHERNET PORT 4 9 MAINTENANCE 5 TECHNICAL SPECIFICATIONS 6 CONTACT AND LINK Page sur 3 21 AUDIOFOCUS S series USER S MANUAL ...

Страница 4: ...1 2003 A2 2005 EN61000 3 2 2000 A2 2005 EN61000 3 2 2295 A1 2001 A2 2005 Ing Xavier Marchal Audiofocus R D Director Maximum load have been tested and approved by Vinçotte s a CERTEST Products 2 2 HANDLING Keep the device away from moisture AF is not responsible for third party material use for example foot lift 2 3 SOUND LEVEL S series subwoofer can deliver high sound pressure level that could dam...

Страница 5: ...ry 3 2 S serie subwoofer S series are a subwoofer speakers suitable for a wide range of sound reinforcement applications from small to large scale concerts or theaters where sound quality is crucial The S series subwoofer is active from 25Hz S21 35 Hz S18 45Hz S15 to 110Hz S series subwoofer come as an active self powered unit The amplified version is driven with the recommend AUDIOFOCUS amplifier...

Страница 6: ...k amp cover protect the system from direct rain an direct sunlight Ambient temperature and amplifier temperature are related but not the same amplifier start limiting at 75 c Transport cover for S series subwoofer are recommended to ensure a long life to the system Wheel board are recommended to ensure a long life to the system Page sur 6 21 AUDIOFOCUS S series USER S MANUAL ...

Страница 7: ...Back wheels option is available on request Page sur 7 21 AUDIOFOCUS S series USER S MANUAL ...

Страница 8: ...4 SETUP 4 1 S15 S18 DISPLAY Page sur 8 21 AUDIOFOCUS S series USER S MANUAL Encoder Fonction description Status LED Signal LED Preset description ...

Страница 9: ...l led blink while changes are being made The four LEVEL PRESET led display the level adjustment 4 3 PRESET SELECTION S15 S18 Presets are subjects to improvement Please check on our web site for last version S15 and S18 DSP provide 8 preset Page sur 9 21 AUDIOFOCUS S series USER S MANUAL ...

Страница 10: ...t1 Preset4 SUB ENDIFRE Cabinet is use in end fire configuration see graphic below with preset1 Preset 5 110 CARDIO Cabinet is use in cardioid configuration see graphic below with preset2 PRESET6 110 END FIRE Cabinet is use in end fire configuration see graphic below with preset2 Page sur 10 21 AUDIOFOCUS S series USER S MANUAL Preset 1 or 2 Preset 1 or 2 Preset 3 or 5 ...

Страница 11: ...le mounted PRESET8 FRX POL Phase and time match the FRX DSP pole mounted 4 4 DELAY S15 S18 Pushing the rotative encoder 5seconds give access to delay selection Each step is 5meters delay increase For longer or accurate tuning use the AFNetworkManager software Page sur 11 21 AUDIOFOCUS S series USER S MANUAL ...

Страница 12: ... I O and link for AFnetwork management and Dante IO if Dante option chosen Knob one turn and push all function knob LED display menu and information The one knob push and turn is an easy way to navigated thru menu and select parameters Pushing it will give access to MAIN MENU which display different sub menu Turn knobs and push a second time to enter the displayed sub menu parameters Page sur 12 2...

Страница 13: ...till the right name is display than push the knobs to recall the preset The firmware go back to main screen automatically SET IP Change the IP address of the amplifier This is related to the AF network manager software our dedicate software remote control of the amplifier with computer Turning the knobs change the sector number and pushing the knobs selected the next sector SOURCE Selection of the...

Страница 14: ...to 110Hz PRESET5 110 END FIRE Speaker is use in end fire configuration see graphic below with preset4 PRESET6 110 CARDIO Speaker is use in cardioid configuration see graphic below with preset4 PRESET7 ARES8 POL Speaker is used with ARES8 pole mounted on it PRESET8 FRX POL Speaker is used with FRX pole mounted on it PRESET9 BASS Speaker response go from 45Hz to 110Hz PRESET10 BASS CARDIO Speaker is...

Страница 15: ...front speaker is 124cm CARDIO CONFIG Use the deported connector option on front grill for an optimal cabling configuration Page sur 15 21 AUDIOFOCUS S series USER S MANUAL Preset 2 or 5 Preset 1 or 4 Preset 1 4 or 11 Preset 3 6 or 12 REAR VIEW FRONT 124cm front to back BACK ...

Страница 16: ...t power and signal cables as describe on the technical drawing Make sure the preset volume are right Check the signal output before application and lifting S21 and S18 have an front grill option for cardioid mode connection which prevent from having cables going from the back to the front Page sur 16 21 AUDIOFOCUS S series USER S MANUAL analog In Out AES Ethernet controller In Out AES Dante option...

Страница 17: ...art manual for more information RJ45 port can handle both AF network manager AESOP and Dante option at the same time 4 9 MAINTENANCE Remove the cover if any liquid hit it let it dry If you need to clean it use no agressive product for synthetic material You want to have regular check of the general aspect of the cabinet Wood paint part can be clean with maintenance furniture product metal part wit...

Страница 18: ... 132 5 dB Active 135 dB Components 15 LF Faitalpro Custom made 4 Voice coil Line Connectors Active Balanced 1 x IN 1 x OUT Neutrik XLR Front connection for Cardio NO HP Connectors Passive 2x Neutrik speakON linked Construction Birch marine Plywood 15 24 mm Finish High resistant Polyurea coating Dimensions h x w x d 485 x 580 x 520 mm 19 09 x 22 83 x 20 47 Weight Passive 34 kg 75 lb Active 35 kg 77...

Страница 19: ...italpro Custom made 4 Voice coil Line Connectors Active Balanced 1 x IN 1 x OUT Neutrik XLR Front connection for Cardio Active powerCON and XLR IN OUT Passive speakON 4 or speakON 8 IN OUT HP Connectors Passive 2x Neutrik speakON linked Construction Birch marine Plywood 15 24 mm Finish High resistant Polyurea coating Dimensions h x w x d 510 x 650 x 560 mm 20 07 x 25 59 x 22 04 Weight Passive 39 k...

Страница 20: ...145 dB Components 21 LF B C Custom made 4 5 Voice coil Line Connectors Active Balanced 1 x IN 1 x OUT Neutrik XLR Front connection for Cardio Active powerCON and XLR IN OUT Passive speakON 4 or speakON 8 IN OUT HP Connectors Passive 2x Neutrik speakON linked Construction Birch marine Plywood 15 24 mm Finish High resistant Polyurea coating Dimensions h x w x d 590 x 750 x 655 mm 23 22 x 29 52 x 25 ...

Страница 21: ...6 CONTACT AND LINK www audiofocus eu info audiofocus eu www facebook com AudiofocusPage www facebook com groups AUDIOFOCUS Page sur 21 21 AUDIOFOCUS S series USER S MANUAL ...

Отзывы: