Audiocom ICW-3 Скачать руководство пользователя страница 6

6

Vox Circuit Adjustment

NOTE

: The unit is shipped from the factory with the VOX 

circuit pre-adjusted. Use this procedure only if you encoun-
ter a problem where the VOX circuit does not properly 
switch between the operator and customer when they are 
talking. In some situations, particularly when ambient noise 
levels vary over time, it may be necessary to “touch up” the 
VOX adjustments.

1.

Locate the two VOX pots: VOX1 and VOX2. They are 
located on the operator assembly side of the unit.

2.

Set VOX1 (top hole) all the way clockwise. Set VOX2 
(bottom hole) all the way clockwise

3.

Locate the customer and operator volume controls. they 
are located on the operator side of the unit. Set each of 
them to the middle of their adjustment range.

4.

Have an assistant talk on the outside microphone and 
using the included screwdriver adjust VOX2 (bottom 
hole) so that the VOX just triggers and you can be heard 
by your assistant on the speaker on the customer side. 
Then turn the pot just a little further.

5.

Talk back and forth and adjust VOX1 (top hole) and 
VOX2 (bottom hole) very carefully to get the proper 
VOX switching action. Be sure to talk directly into the 
microphones because they are close talking.

FIGURE 3.

Operator and Customer assemblies

FIGURE 4.

Mounting Template

FIGURE 5.

Customer Side Mounted

FIGURE 6.

Connecting customer and operator 

assemblies prior to final mounting.

Содержание ICW-3

Страница 1: ...ICW 3 Window Intercom Installation and Operation Instructions 9350 7686 000 Rev L 8 2006...

Страница 2: ...2 467 3279 Factory Service 800 553 5992 Please include a note in the box which supplies the company name address phone number a person to contact regarding the repair the type and quantity of equipmen...

Страница 3: ...Items 1 No 1 Phillips screwdriver 2 Equipment for cutting drilling hole s for mounting See Installation section for details 3 1 wide transparent tape 4 Scissors For cutting the mounting template from...

Страница 4: ...ng Note These are sine wave maximums Voice measurements will range 70 to 90 dB SPL Headphones 80 mW 100dB peak SPL Voice Range 84 to 104 dB SPL Impedance 25 ohms Inputs Internal Panel Microphone Elect...

Страница 5: ...l the hole s from the customer assembly side 5 Have an assistant place the customer assembly against the window Make sure the holes line up correctly Attach the mounting plate removed from the operato...

Страница 6: ...customer and operator volume controls they are located on the operator side of the unit Set each of them to the middle of their adjustment range 4 Have an assistant talk on the outside microphone and...

Страница 7: ...onnector VOX1 outside Circuit Adjustment customer side Headphone connector VOX2 inside Circuit Adjustment operator side Controls volume of the loudspeaker on the customer side Rotate knob clockwise to...

Страница 8: ......

Страница 9: ......

Страница 10: ......

Отзывы: