CHAPTER 7 SNMP Traps
Mediant 800 SBC | SNMP Reference Guide
HA Ethernet Group Alarm
Table 7-15: acHAEthernetGroupAlarm
Alarm
acHAEthernetGroupAlarm
OID
1.3.6.1.4.1.5003.9.10.1.21.2.0.137
Description
The alarm is sent when the Ethernet link of at least one port in the
Ethernet Group that is associated with the HA Maintenance
interface is down.
Default Severity
Minor
Source Varbind Text
system#0
Event Type
qualityOfServiceAlarm
Probable Cause
outOfService
Severity
Condition
Text
Corrective Action
Minor
At least one of the
Ethernet port links
in the Ethernet
Group associated
with the HA
Maintenance
interface is down
"SYS_HA:
Maintenance
Group - One of the
links is down - NO
HA of maintenance
link redundancy"
Check that the
Ethernet cables are
connected securely
to the ports. Check
that the ports at the
other end are up
(working).
Cleared
All Ethernet ports in
the Ethernet Group
associated with the
HA Maintenance
interface become
up again
-
-
Board Alarms
The source varbind text for all alarms under this component is System#0<n>, where
n
is the
slot number in which the blade resides in the chassis.