5. Default Settings
5 Default
Settings
You can restore the device's factory default settings or define your own default settings for
the device.
5.1
Defining Default Settings
The device is shipped with factory default configuration values stored on its non-volatile
memory (flash). However, you can define your own default values instead of using the
factory defaults. This is performed using an
ini
file that includes the header
'[ClientDefaults]'. Below this header, simply define new default values for the required
ini
file
parameters. The parameters are defined in the same format as in the standard
ini
file, and
loaded to the device using TFTP (i.e., not via the Web interface).
An example of a ClientsDefault
ini
file for defining default values for Syslog server
parameters is shown below:
[ClientDefaults]
EnableSyslog = 1
SyslogServerIP = 10.13.2.20
¾
To define default values for device parameters, take these 2 steps:
1.
Configure the ClientDefaults
ini
file with new default parameter values, as required.
2.
Load the ClientDefaults
ini
file to the device, using TFTP (refer to the
Product
Reference Manual
).
¾
To remove user-defined defaults and restore factory default values,
take this step:
Load an empty (i.e., without any parameters) ClientDefaults
ini
file to the device, using
TFTP.
5.2
Restoring Factory Defaults
You can restore all or most of the device's configuration settings to default settings:
Restoring default settings except for the device's IP address and Web interface's login
user name and password: Load to the device an empty
ini
file (without any parameters
or with a semicolon (;) preceding all lines). When a parameter is absent from a loaded
ini
file, the default value is assigned to that parameter (according to the
cmp
file loaded
to the device) and saved to the non-volatile memory (thereby, overriding the value
previously defined for that parameter).
Restoring all default settings, including the device's IP address and Web interface's
login user name and password: Use the device's hardware Reset button (refer to the
device's
Installation Manual
).
Содержание Mediant 2000
Страница 1: ...Document LTRT 68808 November 2008 User s Manual Version 5 6 ...
Страница 2: ......
Страница 18: ...SIP User s Manual 18 Document LTRT 68808 Mediant 2000 Reader s Notes ...
Страница 83: ...Version 5 6 83 November 2008 SIP User s Manual 3 Web Based Management Figure 3 47 Trunk Settings Page ...
Страница 254: ...SIP User s Manual 254 Document LTRT 68808 Mediant 2000 Reader s Notes ...
Страница 334: ...SIP User s Manual 334 Document LTRT 68808 Mediant 2000 Reader s Notes ...
Страница 342: ...SIP User s Manual 342 Document LTRT 68808 Mediant 2000 Reader s Notes ...
Страница 408: ...SIP User s Manual 408 Document LTRT 68808 Mediant 2000 Reader s Notes ...
Страница 414: ...SIP User s Manual 414 Document LTRT 68808 Mediant 2000 Reader s Notes ...
Страница 418: ...User s Manual Version 5 6 www audiocodes com ...