background image

Installation & Maintenance Manual 

 

20. Configuring FXS Ports and PSTN Trunks 

Version 6.8 

173 

Microsoft Lync Server 

20  Configuring FXS Ports and PSTN Trunks 

This section describes how to configure FXS ports and PRI (i.e., E1/T1) or BRI trunks 

connected to the PSTN Gateway.  

20.1  Enabling FXS Ports and PSTN Trunks 

The procedure below describes how to enable the FXS ports and PSTN trunk (E1/T1) 

channels of the Enhanced gateway. This is done by defining telephone numbers for the 

channels and assigning them to Trunk Groups. To ensure correct routing of IP-to-Tel calls, 

you need to define different Trunk Groups for the digital trunk and the FXS module. 

 

To enable the FXS ports and PSTN trunks: 

1. 

Open the Trunk Group Table page (

Configuration

 tab > 

VoIP

 menu > 

GW

 a

nd IP to 

IP 

 > 

Trunk

 

Group

 > 

Trunk Group

). 

Figure 

 

20-1: Trunk Group Table Page 

 

 

2. 

Define the following Trunk Groups: 

 

Trunk Group #2: PRI module (E1/T1) with one span (1-31 channels)  

 

Trunk Group #1: FXS module with two FXS channels – Channel 1 with phone 

17326521000 and Channel 2 with phone 17326521001 

 

Those numbers need to be configured as TelUri numbers for analog devices in 

Lync environment using the powershell command New-CsAnalogDevice. 

3. 

Click 

Submit

 to apply your settings. 

4. 

On the toolbar, click 

Burn

  to save the changes to the Enhanced gateway flash 

memory. 

 

 

Содержание Mediant 1000B SBA

Страница 1: ...Version 6 8 April 2016 Document LTRT 40111 SBA Installation and Maintenance Manual Mediant 1000B SBA for Microsoft Lync Server Microsoft Lync Server Survivable Branch Appliance Mediant 1000B SBA...

Страница 2: ......

Страница 3: ...ce 39 6 2 Connecting to LAN with Port Pair Redundancy 41 6 3 Connecting to FXS Interfaces 43 6 4 Connecting to ISDN BRI Interfaces 44 6 4 1 Connecting to BRI Lines 44 6 4 2 Connecting the PSTN Fallbac...

Страница 4: ...ecurity 121 11 15 1 Apply No Policy 121 11 15 2 Apply Default Security Template 123 11 15 3 Apply User Defined Security Template 126 11 16Step 16 Optional Remote Control 129 11 17Step 17 Optional SNMP...

Страница 5: ...grading the SBA Components 191 24 Upgrading MSFT and CU System Components 193 25 Upgrading the Management Interface 197 26 Upgrading using the SBA ProConnect 201 Upgrading and Recovering the SBA Image...

Страница 6: ...Windows Update Policy 258 A 6 Firewall Rules 258 A 6 1 Default SBA Internal Firewall Rules 258 A 6 2 SBA Network Firewall Settings 276 B Running Anti Virus Software 279 C Upgrading Hardware 281 C 1 V...

Страница 7: ...4 Maintenance Actions Reset Gateway 50 Figure 7 5 Physical Ports Settings Page 51 Figure 8 1 New Object Computer Dialog Box 55 Figure 8 2 RTCUniversalReadOnlyAdmins 56 Figure 9 1 Menu Path to Topology...

Страница 8: ...d 97 Figure 11 29 Device Preparation Reboot Message Box 98 Figure 11 30 Device Preparation Completed Successfully 98 Figure 11 31 Cs Database installation Screen 99 Figure 11 32 Cs Database Installati...

Страница 9: ...up Setup Completed 136 Figure 11 86 Complete Setup Completed Successfully 137 Figure 11 87 Home Page 138 Figure 11 88 Start and Stop Service Page 139 Figure 11 89 Logs Screen Displaying Logged Events...

Страница 10: ...for Serial Communication 223 Figure 30 7 Cabling OSN3 to PC for Serial Communication 223 Figure 30 8 Windows Loading Files 224 Figure 30 9 SAC Started 224 Figure 30 10 SAC Initialized 225 Figure 30 1...

Страница 11: ...LEDs Description 33 Table 5 7 Gigabit Ethernet Interface RJ 45 Connector Pinouts 35 Table 5 8 RS 232 Serial Cable Connector Pinouts 35 Table 5 9 HDMX Module LED Description 36 Table 7 1 Physical Port...

Страница 12: ...Installation Maintenance Manual 12 Document LTRT 40111 Mediant 1000B SBA This page is left intentionally blank...

Страница 13: ...N SmartTAP VMAS VoIPerfect VoIPerfectHD Your Gateway To VoIP 3GX VocaNOM and CloudBond 365 are trademarks or registered trademarks of AudioCodes Limited All other products or trademarks are property o...

Страница 14: ...Installation Maintenance Manual 14 Document LTRT 40111 Mediant 1000B SBA Related Documentation Manual Name Mediant 1000B SBA Quick Guide...

Страница 15: ...voice services to branch users during a WAN outage a branch office survivability solution the Survivable Branch Appliance SBA application is hosted on the OSN Server platform running on AudioCodes Me...

Страница 16: ...aintenance Manual 16 Document LTRT 40111 Mediant 1000B SBA Figure 1 1 SBA Home Page Additional AudioCodes Applications Link New SBA Image Figure 1 2 SBA Home Page Additional AudioCodes Applications Li...

Страница 17: ...stallation Maintenance Manual 1 Introduction Version 6 8 17 Microsoft Lync Server The figure below illustrates typical SBA branch office deployment scenarios Figure 1 3 Typical Branch Office Deploymen...

Страница 18: ...Maintenance Manual 18 Document LTRT 40111 Mediant 1000B SBA A summary of the steps required to setup the SBA environment is shown in the figure below Figure 1 4 Summary of Steps for Installing and Con...

Страница 19: ...s Cable mini HDMI to HDMI 1 5m for monitor connections Cable micro USB to USB 1 5m for serial connections One or two AC power cables depending on customer order USB dongle for SBA software upgrade and...

Страница 20: ...Installation Maintenance Manual 20 Document LTRT 40111 Mediant 1000B SBA This page is left intentionally blank...

Страница 21: ...and E SBC chassis The chassis s panels are described as follows Front Panel see Section 3 on page 23 Rear Panel see Section 4 on page 25 The AudioCodes SBA is installed on the HDMX disk module and run...

Страница 22: ......

Страница 23: ...ce of this module depends on the ordered configuration If in the future you need to add such interfaces to your device you can order this module separately TRUNKS TRUNKS E1 TE J1 module Note The prese...

Страница 24: ...2 Each power supply unit provides an AC power connector on its rear panel If both Power 1 and Power 2 units are used the load is shared between them This optional load sharing feature enables power f...

Страница 25: ...1 Protective earthing screw 2 ESD Electrostatic Discharge ESD socket 3 100 240V 1A Dual AC Power Supply Entries 4 OSN3B or OSN4 OSN3B or OSN4 AMC module Note OSN3 module is no longer available for pur...

Страница 26: ...Installation Maintenance Manual 26 Document LTRT 40111 Mediant 1000B SBA This page is intentionally left blank...

Страница 27: ...ty shortens boot up time and increases the mean time between failures MTBF This enhanced Mediant 1000B SBA ES enables customers to run third party IT software for example anti virus and monitoring age...

Страница 28: ...cribed in the subsequent table Figure 5 1 OSN3B and OSN4 Module Ports Table 5 1 OSN3B and OSN4 Module Port Description Item Label Description 1 USB 2 0 port 2 Two RJ 45 ports for Gigabit Ethernet The...

Страница 29: ...OSN3B and OSN4 module LEDs are shown in the figure below and described in the subsequent table Figure 5 2 OSN3B and OSN4 Module LEDs Table 5 3 OSN3B and OSN4 Module LEDs Description Item Color State...

Страница 30: ...n Off 10Base T connection if LED 3 is active 5 Blue Flashing Module undergoing shutdown sequence when handle is pulled out to first extraction position or module had been inserted and handle is still...

Страница 31: ...described in the table below Table 5 4 HDMI Type D Connector Pinouts Pin Signal 3 TMDS Data2 4 TMDS Data2 Shield 5 TMDS Data2 6 TMDS Data1 7 TMDS Data1 Shield 8 TMDS Data1 9 TMDS Data0 10 TMDS Data0 S...

Страница 32: ...the SBA with the OSN3 module 5 2 1 Ports Description The OSN3 module is shown below and described in the subsequent table Figure 5 3 OSN3 Module Ports Table 5 5 OSN3 Module Port Description Item Label...

Страница 33: ...a processor over temperature above 125 C and as a result the module shuts down Off Normal operation 3 2 Red On When lit during boot up indicates clock failure Flashing Chipset over temperature above 1...

Страница 34: ...s slot 7 Red On Hardware failure supplied voltage is not within normal operating range ensure CRMX is installed in chassis Flashing Upgrade in progress Off Normal operation 8 SPEED Green On 100Base TX...

Страница 35: ...ctor Pinouts Pin 100Base Tx 1000Base T I O Signal Signal Function 1 O Tx I O BI_DA 2 0 Tx I O BI_DA 3 I Rx I O BI_DB 4 I O BI_DC 5 I O BI_DC 6 I Rx I O BI_DB 7 I O BI_DD 8 I O BI_DD 5 2 4 Serial Cable...

Страница 36: ...be ordered with dual hard disk drives i e two HDMX modules The HDMX module is available as either an HDD drive or as an SSD drive The HDMX module is shown below and described in the subsequent table F...

Страница 37: ...Part II Setting up the Mediant 1000B PSTN Gateway This part describes how to cable the Mediant 1000B PSTN gateway and how to connect it to the IP network...

Страница 38: ......

Страница 39: ...e The procedure below describes how to ground the device Protective Earthing The equipment is classified as Class I EN 60950 and UL 60950 and must be earthed at all times using an equipment earthing c...

Страница 40: ...Installation Maintenance Manual 40 Document LTRT 40111 Mediant 1000B SBA This page is intentionally left blank...

Страница 41: ...tandby LAN port If your deployment requires additional ethernet ports you can order the optional SWX module which provides four Ethernet ports Note The SWX module is an optional customer orderable ite...

Страница 42: ...t on the CRMX or SWX module Figure 6 4 Connecting to LAN 2 Connect the other end of the cable to the LAN 3 For 1 1 LAN protection repeat Steps 1 and 2 for the standby port but connect it to another ne...

Страница 43: ...nsure that FXS ports are connected to the appropriate external devices otherwise damage to the device may occur The FXS ports are considered as TNV 2 Note The FXS module is a customer ordered item Thi...

Страница 44: ...ble only if your device is installed with such a module To connect to BRI lines 1 Connect the BRI cable to the device s BRI RJ 45 port 2 Connect the other end of the cable to your ISDN telephone or PB...

Страница 45: ...e Port 3 III to Port 4 IIII of the same BRI module For example if a PBX trunk is connected to Port 1 and the PSTN network is connected to Port 2 when PSTN Fallback is activated calls from the PBX are...

Страница 46: ...lectrical shock and fire use a 26 AWG min wire to connect T1 or E1 ports to the PSTN Note The TRUNKS module is a customer ordered item This section is applicable only if your device is installed with...

Страница 47: ...irectly to the PSTN through Port 2 To connect the digital trunk interfaces for 1 1 PSTN Fallback 1 Connect Trunk 1 to a PBX 2 On the same TRUNKS module connect Trunk 2 to the PSTN Figure 6 9 Cabling P...

Страница 48: ...e device s rear panel The dual power option provides the device with power redundancy If both power units are used for load sharing failure protection redundancy ensure that you connect each power sup...

Страница 49: ...ngs 7 1 Initial Access to the PSTN Gateway Before you can configure the PSTN Gateway you need to access its Web interface using the default VoIP Management LAN IP address as described in below To init...

Страница 50: ...ection 7 3 on page 51 2 Configure a LAN network address so that it corresponds to your network IP addressing scheme and configure the physical LAN port pair in the Multiple Interface Table page Config...

Страница 51: ...fferent physical ports is not accessible to one another The only connection between them can be established by cross connecting them with media streams a VoIP calls For each LAN port you can configure...

Страница 52: ...acket without a VLAN otherwise the VLAN ID as defined in the Multiple Interface table takes precedence The valid value range is 1 to 4096 The default is 1 Speed Duplex Defines the speed and duplex mod...

Страница 53: ...d at headquarters Add the SBA Device to the Active Directory AD See Chapter 8 on page 55 Create a user account on the AD belonging to the RTCUniversalSBATechnicians group This user performs the SBA de...

Страница 54: ......

Страница 55: ...and Computers b Add the Survivable Branch Appliance device name to the domain computers right click Computers choose New and then click Computer Figure 8 1 New Object Computer Dialog Box c Click Chan...

Страница 56: ...pliance computer name that you created in Step b above and then choose Properties g In the Attributes list set servicePrincipalName to HOST SBA FQDN where SBA FQDN is the FQDN of your Survivable Branc...

Страница 57: ...w to add the Survivable Branch Appliance to your topology using Lync Server 2013 Topology Builder This configuration includes the following main steps Defining the branch office see Section 9 1 on pag...

Страница 58: ...ine the branch office To create branch sites 1 Start the Lync Server 2013 Topology Builder program a Start menu All Programs Microsoft Lync Server 2013 Lync Server Topology Builder or b Start menu All...

Страница 59: ...the Branch Office Topology using Topology Builder Version 6 8 59 Microsoft Lync Server Figure 9 2 Menu Path to Topology Builder Program Lync 2010 The Topology Builder opens as shown in the examples b...

Страница 60: ...Download Topology from existing deployment option assuming your Lync Server 2013 or Lync Server 2010 deployment already has a topology and then click OK a dialog box opens prompting you to save the ex...

Страница 61: ...ng tool to design your Enterprise Voice topology expand the Branch sites node and then expand the name of the branch site you specified in the tool To modify each section of the branch office right cl...

Страница 62: ...g box do the following a In the Name field type the name of the branch site Only this field is required the other fields are optional b In the Description field type a meaningful description of the br...

Страница 63: ...he name of the state or region in which the branch site is located c In the Country Region Code field type the two digit calling code for the country in which the branch site is located d Click Next t...

Страница 64: ...you configured in the FQDN field must be the same as the FQDN that you configured using the ADSI Edit program in Section 0 on page 39 The following dialog box appears Figure 9 11 Select the Front End...

Страница 65: ...r Version 6 8 65 Microsoft Lync Server 10 From the Edge pool drop down list select the Edge pool to be used with this SBA optional and then click Next the following dialog box example screens appear F...

Страница 66: ...is configured to resolve the FQDN into this IP address b In the Listening port for IP PSTN Gateway field type the Gateway listening port This must be the same port as configured in the PSTN Gateway as...

Страница 67: ...pology Once you have defined the Branch Office as described in the previous section you need to publish this new topology as described below To publish the topology 1 Right click the root of the Lync...

Страница 68: ...Maintenance Manual 68 Document LTRT 40111 Mediant 1000B SBA 2 Click Next the following screen appears Figure 9 17 Publish Wizard Complete 3 Verify that all steps display the Success status and then c...

Страница 69: ...4 Part IV Setting up the SBA Management Interface This part describes how to connect to the SBA Management interface and to install and configure the SBA...

Страница 70: ......

Страница 71: ...thods Using the internal NIC the SBA is connected to the network via the gateway SBC Ethernet port and the device s internal switch See below If this option is used only a single network cable is requ...

Страница 72: ...to the SBA using the internal NIC 1 Connect the first Ethernet port on the CRMX module on the front panel of the device directly to the network using a straight through Ethernet cable Figure 10 1 Con...

Страница 73: ...e and then do one of the following If you have a DHCP server in your network note the IP address assigned to the Ethernet port If you are not using a DHCP server then assign a static IP address to the...

Страница 74: ...the Internet Download this driver at http www silabs com products mcu pages usbtouartbridgevcpdrivers aspx 4 Establish a serial communication with the OSN server using a terminal emulation program su...

Страница 75: ...e IP address that was determined in Step 6 above The Survivable Branch Appliance Management Interface opens Figure 10 5 Welcome to SBA Screen 10 Log in with the default username Administrator and pass...

Страница 76: ...our network environment To initially connect to the SBA using the external NIC 1 Using a network cable connect the PC to the appropriate Ethernet port On the OSN3B OSN4 module connect to Port 1 Figure...

Страница 77: ...erface opens Figure 10 9 Welcome to SBA Screen 4 Log in with the default username Administrator and password Pass123 Select the Yes I accept the term and condition checkbox and then click Login the Ho...

Страница 78: ...Installation Maintenance Manual 78 Document LTRT 40111 Mediant 1000B SBA This page is intentionally left blank...

Страница 79: ...on 11 6 on page 96 7 Cs Database Installation See Section 11 7 on page 99 8 Backup See Section 11 8 on page 101 9 Enable Replication See Section 11 9 on page 103 10 Activate Lync See Section 11 10 on...

Страница 80: ...menu screens the current CPU of the OSN module is displayed in the background In the Setup pane a list of all the configurable items is displayed Table 11 1 Setup Pane Icon Setup Pane Icon Description...

Страница 81: ...ox for those interfaces that you are not using 2 From the drop down list select one of the following NIC interface options External1 Corresponds to one of the physical Ethernet ports on the Mediant 10...

Страница 82: ...the disconnected external NIC is labeled Local Area Connection 2 the disconnected internal NIC is labeled Local Area Connection 3 and the connected external NIC is labeled Local Area Connection 4 Note...

Страница 83: ...icrosoft Lync Server Figure 11 5 IP Settings Login Again 10 Click OK A new login screen appears 11 Enter the Username Password and then click Login Notes The system logs in with the new IP address Eve...

Страница 84: ...ion Maintenance Manual 84 Document LTRT 40111 Mediant 1000B SBA A green check mark is displayed next to the IP Settings option under the Setup tab as shown in the figure below Figure 11 6 IP Settings...

Страница 85: ...will then be rebooted After the server reboots the following message appears The SBA server has been rebooted automatically You can then login to the SBA Management Interface Once you join to the Dom...

Страница 86: ...e also appears to advise that a re boot is necessary for the setting to take effect Figure 11 8 Reboot Computer after Computer Name Change 4 Click Reboot the SBA server reboots and the following scree...

Страница 87: ...ure 11 10 Login Screen 5 Enter your username and password and then click Login to log in once again to the SBA Management Interface the Setup tab appears displaying a green check mark next to the Chan...

Страница 88: ...Administrator password 1 Select the Setup tab and then select the Change Admin Password check box the following screen is displayed Figure 11 12 Change Admin Password Screen 2 In the Current Password...

Страница 89: ...soft Lync Server Figure 11 13 Change Admin Password Applied Changes 5 Click Next to proceed to the next setup task a green check mark appears next to the Change Admin Password option under the Setup t...

Страница 90: ...te and Time option resets the date and time zone To set the date and time 1 Select the Setup tab and then select the Set Date and Time check box the following screen is displayed Figure 11 15 Set Date...

Страница 91: ...Operation Completed Successfully message appears on the bottom of the screen 6 Click Apply a notification message box appears Figure 11 17 Set Date and Time Notification Message 7 Click OK the followi...

Страница 92: ...Installation Maintenance Manual 92 Document LTRT 40111 Mediant 1000B SBA Figure 11 19 Set Date and Time Completed Successfully...

Страница 93: ...after a session timeout When this occurs the login screen appears with the following popup message The SBA server needs to be rebooted Please insert your credentials and click on Login The server wil...

Страница 94: ...account that has permission to join the SBA to the domain as configured in Chapter 9 on page 57 4 In the Group name field ensure that the RTCUniversalSBATechnicians value is selected 5 Click Apply a...

Страница 95: ...n user check box which is selected by default Figure 11 24 Welcome to SBA 8 Log in with the Domain user username and password and then click Login a green check mark is displayed next to the Join to a...

Страница 96: ...popup message The SBA server needs to be rebooted Please insert your credentials and click on Login The server will then be rebooted After the server reboots the following message appears The SBA serv...

Страница 97: ...lling and Configuring the SBA Version 6 8 97 Microsoft Lync Server Figure 11 27 Device Preparation Started Figure 11 28 Device Preparation All Components Installed 3 When the installation completes yo...

Страница 98: ...ted successfully click Reboot If you wish to review some of the steps refer to the Detailed Log for corrective information rectify the problem and then click Apply to install the remaining components...

Страница 99: ...lation The Cs Database installation option installs CsDatabase for Lyss and registrar Note This step is not relevant for Microsoft Lync Server 2010 deployments To install the CsDatabase 1 Select the S...

Страница 100: ...000B SBA 2 Click Apply the following screen appears Figure 11 32 Cs Database Installation Applied Successfully A green check mark appears next to the Cs Database option under the Setup tab as shown in...

Страница 101: ...up option creates a backup copy of the Central Management Server on the SBA server To create a backup of the Central Management Server 1 Select the Setup tab and then select the Backup check box the f...

Страница 102: ...ion Maintenance Manual 102 Document LTRT 40111 Mediant 1000B SBA A green check mark appears next to the Backup option under the Setup tab as shown in the figure below Figure 11 36 Backup Completed Suc...

Страница 103: ...Management Server The actual replication is executed after all Lync services have been enabled after Step 12 has been completed see Section 11 12 on page 113 To enable replication 1 Select the Setup...

Страница 104: ...nable Replication option under the Setup tab as shown in the figure below Figure 11 39 Enable Replication Completed Successfully Note The replication status may not immiediately display the status Up...

Страница 105: ...Installing the required software does not automatically cause the SBA server machine to adopt a new service role instead it must be activated before it actually begins to function in its new role To a...

Страница 106: ...ntenance Manual 106 Document LTRT 40111 Mediant 1000B SBA A green check mark appears next to the Activate Lync option under the Setup tab as shown in the figure below Figure 11 42 Activate Lync Comple...

Страница 107: ...server and the Central Management Server To install a Certificate Select the Setup tab and then select the Lync Certificate check box the following screen appears Figure 11 43 Lync Certificate Screen...

Страница 108: ...ificate radio button Figure 11 44 Request Certificate 2 Requesting a certificate supports Auto enrollment Enter all fields Those fields beginning with a CA prefix are mandatory The correct Certificate...

Страница 109: ...uring the SBA Version 6 8 109 Microsoft Lync Server Figure 11 45 Lync Certificate Detailed Log 3 If the CA field is not entered the system creates an enrollment certificate which can be downloaded Fig...

Страница 110: ...nrolled Certificate 5 Click the Download Enrolled Certificate link the following screen appears Figure 11 48 Lync Certificate File Download 6 Click Save 7 Once the Enrollment Certificate has been sign...

Страница 111: ...tenance Manual 11 Installing and Configuring the SBA Version 6 8 111 Microsoft Lync Server Figure 11 49 Lync Certificate File Upload 8 Click Apply the following screen appears Figure 11 50 Lync Certif...

Страница 112: ...Maintenance Manual 112 Document LTRT 40111 Mediant 1000B SBA A green check mark appears next to the Lync Certificate option under the Setup tab as shown in the figure below Figure 11 51 Lync Certific...

Страница 113: ...rver 2013 formerly termed Communications Server component that runs as a Windows service To start Lync services 1 Select the Setup tab and then select the Start Lync Services check box the following s...

Страница 114: ...ces option under the Setup tab and in the Lync Services information pane all of the Lync Services are shown as Running as shown in the figure below Figure 11 54 Start Lync Services Completed Successfu...

Страница 115: ...anual To configure the gateway and run test calls 1 Select the Setup tab and then select the Gateway Configuration check box the following screen appears Figure 11 55 Gateway and Endpoint Configuratio...

Страница 116: ...Embedded Telnet Server drop down list select Enable Unsecured c In the Telnet Server TCP Port field ensure that the port used for Telnet is 23 default Figure 11 56 Enabling Telnet 8 Configure PSTN cal...

Страница 117: ...lift the handset and confirm that you can hear the DTMFs The following screen appears when you answer the phone Figure 11 58 Test Call Succeeded Note It is recommended to disable Telnet after making t...

Страница 118: ...al Built in users for HealthMonitoring have been configured using the following commands New CsHealthMonitoringConfiguration Identity XdsGlobalRelativeIdentity FirstTestUserSipUri String SecondTestUse...

Страница 119: ...t Call option the Lync Test Call screen is displayed Figure 11 60 Lync Test Call Screen 2 In the Dial Check Phone Number field enter the PSTN phone number to dial 3 Click Apply to start the test call...

Страница 120: ...tenance Manual 120 Document LTRT 40111 Mediant 1000B SBA A green check mark appears next to the Lync Test Call option under the Setup tab as shown in the figure below Figure 11 62 Lync Test Call Compl...

Страница 121: ...efault security template to the SBA device Upload a security template Load an administrator defined template to the SBA device Note Once a template is loaded you cannot perform rollback using the SBA...

Страница 122: ...enance Manual 122 Document LTRT 40111 Mediant 1000B SBA 2 Select the No Policy skip action check box option and then click Apply the following screen is displayed Figure 11 64 Confirmation Security Po...

Страница 123: ...ver 11 15 2 Apply Default Security Template This procedure describes how to apply the default security template To apply the default security template 1 Select the Setup tab and then click the Apply S...

Страница 124: ...k Apply the SBA automatically logs out Figure 11 66 System Logout Default Security Template Applied 3 Click OK for the system to log out while running the security template the following screen appear...

Страница 125: ...g and Configuring the SBA Version 6 8 125 Microsoft Lync Server 5 Login and then select the Setup tab A green check mark appears next to the Apply Security option as shown in the figure below Figure 1...

Страница 126: ...ed security template To apply a user defined security template 1 Select the Setup tab and then select the Apply Security check box the following screen is displayed Figure 11 69 Apply Security Policy...

Страница 127: ...hen click Apply the SBA automatically logs out Figure 11 71 System Logout Custom Security Template Applied 4 Click OK for the system to log out while running security template the following screen app...

Страница 128: ...n Maintenance Manual 128 Document LTRT 40111 Mediant 1000B SBA A green check mark appears next to the Apply Security option as shown in the figure below Figure 11 73 Custom Security Template Successfu...

Страница 129: ...sabled and could only be enabled by configuring the parameter PSRemoting Force in the PowerShell RDP Remote Desktop Protocol The RDP is enabled by default for all SBA versions Note If you are using th...

Страница 130: ...ce Manual 130 Document LTRT 40111 Mediant 1000B SBA The following screen is displayed after disabling the Remote Desktop and enabling the Remote Powershell Figure 11 75 Remote Desktop Disabled and Rem...

Страница 131: ...up SNMP 1 Select the Tools tab and then select the SNMP Setup check box The SNMP Setup screen is displayed Figure 11 76 SNMP Setup Screen If the SNMP Service is running an adjacent green sign is indic...

Страница 132: ...al 132 Document LTRT 40111 Mediant 1000B SBA The following screen is displayed Figure 11 77 SNMP Setup Restart Confirmation 7 Click OK and then click Restart The following screen is displayed Figure 1...

Страница 133: ...g the SBA Version 6 8 133 Microsoft Lync Server If the SNMP service is stopped the following screen is displayed Figure 11 79 SNMP Service Started 8 Click Start to start the SNMP service The following...

Страница 134: ...1 Mediant 1000B SBA If SNMP service is not installed the following screen is displayed Figure 11 81 SNMP Service is not Installed 9 Click Install to install the SNMP service the following screen is di...

Страница 135: ...intenance Manual 11 Installing and Configuring the SBA Version 6 8 135 Microsoft Lync Server 10 Click the Tools tab and then select the SNMP Setup check box the following screen is displayed Figure 11...

Страница 136: ...orm the procedure described below to complete the SBA setup To complete SBA setup 1 Log in to the SBA Web wizard if not logged in already 2 Select the Setup tab and then select the Complete Setup chec...

Страница 137: ...Installing and Configuring the SBA Version 6 8 137 Microsoft Lync Server A green check mark appears next to the Complete Setup option under the Setup tab as shown in the figure below Figure 11 86 Com...

Страница 138: ...operating status of the SBA can be viewed in the Home page This page displays the following Central management store location SBA services status stopped or running CPU and network usages Number of in...

Страница 139: ...s menu tab and then select the Start or Stop Service check box the Start and Stop Service page appears Figure 11 88 Start and Stop Service Page 2 Stop or Start the following services Front End Server...

Страница 140: ...aying logged events Figure 11 89 Logs Screen Displaying Logged Events 2 To view details of a logged event select the event Figure 11 90 Detailed Log Display 3 To clear the displayed log click the Clea...

Страница 141: ...art provides step by step procedures for configuring the PSTN Gateway functionality of the Mediant 1000B SBA located at the branch office The configuration is done through the embedded Web server Web...

Страница 142: ......

Страница 143: ...latest GA 6 60A SIP firmware Version The PSTN Gateway must be installed with the following Feature Keys MSFT enables working with Microsoft Lync IPSEC MediaEncryption StrongEncryption and EncryptContr...

Страница 144: ...Installation Maintenance Manual 144 Document LTRT 40111 Mediant 1000B SBA This page is intentionally left blank...

Страница 145: ...sends the INVITE to the next Mediation Server located at the datacenter To configure the Mediation Server 1 Open the Proxy Registration page Configuration tab VoIP menu SIP Definitions Proxy Registrat...

Страница 146: ...ddress as an FQDN ensure that you configure the DNS server see Section 15 1 2 on page 153 b In the Transport Type drop down list select the Transport Type TLS or TCP for these proxies For more informa...

Страница 147: ...W and IP to IP Routing Alternative Routing Reasons Figure 13 3 Reasons for Alternative Routing Page b Under the Tel to IP Reasons group from the Reason 1 drop down list select 503 c Click Submit d Ope...

Страница 148: ...Installation Maintenance Manual 148 Document LTRT 40111 Mediant 1000B SBA This page is intentionally left blank...

Страница 149: ...ty feature and then defining the allowed administrative list IP addresses or FQDNs in the Proxy Set table To allow IP communication only between the PSTN Gateway and Mediation Server 1 Open the Advanc...

Страница 150: ...Installation Maintenance Manual 150 Document LTRT 40111 Mediant 1000B SBA This page is intentionally left blank...

Страница 151: ...or authentication during the TLS handshake with the Mediation Server 15 1 1 Step 1 Enable TLS and Define TLS Port The procedure below describes how to enable TLS and configure the PSTN Gateway ports u...

Страница 152: ...arty NTP server This ensures that the PSTN Gateway has the same date and time as the Certification Authority CA discussed later in Section 15 1 on page 151 To configure the NTP server 1 Open the Appli...

Страница 153: ...tion Server is configured with an FQDN in which case the DNS is used to resolve it into an IP address To configure the DNS servers 1 Open the IP Settings page Configuration tab VoIP menu Network IP Se...

Страница 154: ...ay if required when using certificates for TLS see Section 15 1 5 To configure the SIP gateway name 1 Open the Proxy Registration page Configuration tab VoIP menu SIP Definitions Proxy Registration Fi...

Страница 155: ...ngs In the TLS Version field choose the TLS 1 0 only from the drop down list Use TLS version 1 0 only AudioCodes recommends implementing only TLS to avoid flaws in SSL Figure 15 5 Configuring TLS vers...

Страница 156: ...lder for Lync Server 2013 see Chapter 9 on page 57 7 Copy the CSR from the line BEGIN CERTIFICATE to END CERTIFICATE REQUEST to a text file such as Notepad and then save it to a folder on your compute...

Страница 157: ...Transport Type Version 6 8 157 Microsoft Lync Server Figure 15 8 Request a Certificate Page 10 Click advanced certificate request and then click Next Figure 15 9 Advanced Certificate Request Page 11...

Страница 158: ...d Request field 13 From the Certificate Template drop down list select Web Server 14 Click Submit Figure 15 11 Certificate Issued Page 15 Select the Base 64 encoded option for encoding and then click...

Страница 159: ...les from your computer group click the Browse button corresponding to the Send Device Certificate field navigate to the gateway cer certificate file that you saved on your computer above and then clic...

Страница 160: ...diant 1000B SBA Figure 15 14 Importing Root Certificate into Trusted Certificates Store 23 Click OK the certificate is loaded to the device and listed in the Trusted Certificates store 24 Reset the E...

Страница 161: ...SIP transport type between the PSTN Gateway and the Mediation Server To set SIP transport type to TCP 1 Open the SIP General Parameters page Configuration tab VoIP menu SIP Definitions General Parame...

Страница 162: ...Installation Maintenance Manual 162 Document LTRT 40111 Mediant 1000B SBA This page is intentionally left blank...

Страница 163: ...The PSTN Gateway initiates encrypted calls but if negotiation of the cipher suite fails the call is terminated Incoming calls that don t include encryption information are rejected Preferable Single M...

Страница 164: ...ion Server is configured to Encryption Optional 4 In the Master Key Identifier MKI Size field enter 1 This configures the size in bytes of the MKI in SRTP Tx packets 5 From the Enable Symmetric MKI Ne...

Страница 165: ...abled per coder which is recommended for improving the performance of the Mediation Server The procedure below shows how you can change the default coder To configure the voice coder and silence suppr...

Страница 166: ...Installation Maintenance Manual 166 Document LTRT 40111 Mediant 1000B SBA This page is intentionally left blank...

Страница 167: ...ion comfort noise generation automatic gain control AGC and echo canceller enabled by default Note Silence suppression is configured per coder type as described in Section 0 on page 165 To configure v...

Страница 168: ...ay reset see Step 8 below 8 From the Enable AGC drop down list select Enable 9 Click Submit to apply your changes 10 On the toolbar click Burn to save the changes to the PSTN gateway flash memory 11 O...

Страница 169: ...ceives an ISDN Progress Alerting and Progress Indicator or Connect message For example if the PSTN Gateway receives ISDN Progress it starts sending RTP packets according to initial negotiation but the...

Страница 170: ...ndling The PSTN Gateway opens a voice stream toward the first 18x SIP response that includes an SDP and disregards any 18x response with an SDP received thereafter Figure 19 2 SIP General Parameters P...

Страница 171: ...edia Version 6 8 171 Microsoft Lync Server Figure 19 3 Advanced Parameters Page 7 From the Enable Early 183 drop down list select Enable 8 Click Submit to apply your changes 9 On the toolbar click Bur...

Страница 172: ...Installation Maintenance Manual 172 Document LTRT 40111 Mediant 1000B SBA This page is intentionally left blank...

Страница 173: ...ls you need to define different Trunk Groups for the digital trunk and the FXS module To enable the FXS ports and PSTN trunks 1 Open the Trunk Group Table page Configuration tab VoIP menu GW and IP to...

Страница 174: ...tion tab VoIP menu GW and IP to IP Trunk Group Trunk Group Settings Figure 20 2 Trunk Group Setting Page 2 For the FXS ports i e Trunk Group 1 from the Channel Select Mode drop down list select By Des...

Страница 175: ...to Trunk Group routing rule 1 Open the Inbound IP Routing Table page Configuration tab VoIP menu GW and IP to IP Routing IP to Trunk Group Routing Figure 20 3 Inbound IP Routing Table Page 2 In the f...

Страница 176: ...k Settings Figure 20 4 Trunk Settings Page 2 On the top of the page a bar with trunk number icons displays the status of each trunk Grey disabled Green active Yellow RAI alarm Red LOS LOF alarm Blue A...

Страница 177: ...tings page see Section 20 4 on page 178 To delete a previously configured trunk set the Protocol Type parameter to None b From the Clock Master drop down list select the trunk s clock source Recovered...

Страница 178: ...lly A Law is used for E1 and Mu Law for T1 J1 TDM Bus Clock Source defines the clock source to which the PSTN Gateway synchronizes generate clock from local source Internal or recover clock from PSTN...

Страница 179: ...and inbound calls i e calls destined to Lync clients Number manipulation and mapping of NPI TON to SIP messages rules are configured in the following Manipulation tables For Tel to IP calls Destinati...

Страница 180: ...gn to denote calls without a calling number Source IP Address Defines the source IP address of the caller This is obtained from the Contact header in the INVITE message Notes This parameter is applica...

Страница 181: ...he PreferRouteTable parameter is set to 1 Destination IP Group Defines the IP Group to where the call is sent Notes The value 1 indicates that this field is ignored This parameter is applicable only t...

Страница 182: ...select Unknown 0 International 1 National 2 Network Specific 3 Subscriber 4 or Abbreviated 6 The default is Unknown Notes This parameter is applicable only to number manipulation tables for IP to Tel...

Страница 183: ...irst five digits and add 9 as a prefix to the remaining number Therefore the PSTN Gateway sends the number 95554321 to the PBX and then the PBX sends the number 5554321 to the PSTN 3 National Calls to...

Страница 184: ...erefore the PSTN Gateway sends the number 12063331220 to Lync which relays the call to the Lync client 3 National Calls from a Different Area Code The PSTN user dials the national area code and then a...

Страница 185: ...21 Configuring Normalization Rules for E 164 Format Version 6 8 185 Microsoft Lync Server The configuration of the above scenarios is shown in the figure below Figure 21 3 Destination Phone Number Man...

Страница 186: ...Installation Maintenance Manual 186 Document LTRT 40111 Mediant 1000B SBA This page is intentionally left blank...

Страница 187: ...RTP behavior upon rekey mode 1 Open the Admin page by appending the case sensitive suffix AdminPage to the SBC s IP address in your Web browser s URL field e g http 10 15 9 101 AdminPage Figure 22 1 A...

Страница 188: ...Installation Maintenance Manual 188 Document LTRT 40111 Mediant 1000B SBA This page is intentionally left blank...

Страница 189: ...ote For this feature to work an MPM module is required and media channels should be configured according to the number of FXS ports see below To configure the FXS port transfer feature using the re in...

Страница 190: ...Installation Maintenance Manual 190 Document LTRT 40111 Mediant 1000B SBA Figure 4 29 IP Media Settings 5 Click Submit...

Страница 191: ...Part VI Upgrading the SBA Components This part describes how to upgrade the SBA components...

Страница 192: ......

Страница 193: ...face The following components can be updated Microsoft system components CU updates The LyncServerUpdateInstaller exe provided by Microsoft installs all of the required Microsoft installation componen...

Страница 194: ...oft components are listed in the Installed Components pane 3 In the File to upload field click Browse to select the LyncServerUpdateInstaller exe file to upload and then click Apply The following scre...

Страница 195: ...t automatically and the login screen is displayed Figure 24 4 Login Screen after Automatic Log Out 4 Enter your login and password details and if the Terms and Conditions checkbox is displayed select...

Страница 196: ...Installation Maintenance Manual 196 Document LTRT 40111 Mediant 1000B SBA This page is intentionally left blank...

Страница 197: ...ync Server 25 Upgrading the Management Interface This section describes how to update the SBA Management Interface To update the SBA Management Interface 1 Login to the SBA Management Interface 2 Sele...

Страница 198: ...25 2 System Update Screen 3 In the File to upload field click Browse to select the file to upload and then click Apply the following screen is displayed Figure 25 3 System Update Message SBA Manageme...

Страница 199: ...ut automatically and the login screen is displayed Figure 25 4 Login Screen after Automatic Log Out 4 In the Login screen verify that the new SBA version number is displayed 5 Enter your login and pas...

Страница 200: ...Installation Maintenance Manual 200 Document LTRT 40111 Mediant 1000B SBA This page is intentionally left blank...

Страница 201: ...ir SBA manually Consequently for better servicing of such deployments AudioCodes now offers a new application SBA ProConnect which is a Web Management tool for the purposes of easily installing Micros...

Страница 202: ...Installation Maintenance Manual 202 Document LTRT 40111 Mediant 1000B SBA This page is intentionally left blank...

Страница 203: ...4 Part VII Upgrading and Recovering the SBA Image This part describes how to upgrade the Survivable Branch Appliance SBA software application and how to recover it in case of failure...

Страница 204: ......

Страница 205: ...branch office and provides PSTN termination if implemented for these clients The SBA Upgrade and Recovery procedure is done using AudioCodes SBA Upgrade and Recovery USB dongle which contains a later...

Страница 206: ...Installation Maintenance Manual 206 Document LTRT 40111 Mediant 1000B SBA This page is intentionally left blank...

Страница 207: ...hard disk If you have recently obtained a later SBA image file version it is recommended to copy it to the USB dongle prior to performing the SBA upgrade and recovery and then delete the old image fr...

Страница 208: ...Installation Maintenance Manual 208 Document LTRT 40111 Mediant 1000B SBA This page is intentionally left blank...

Страница 209: ...t based editor such as Notepad the RecoveryUtil ini file located on the USB dongle 3 Perform the required modifications as described in the subsequent subsections 4 Save and close the file 5 Remove th...

Страница 210: ...ecovery automatically without confirmation set the Automatic parameter to 1 as shown below Execution Automatic 1 With this setting the SBA upgrade and recovery starts immediately after the OSN server...

Страница 211: ...n size in Megabytes DiskPartitions MainPartitionSize 100000 Notes The recommended main partition size is 100000 i e 100 Gigabytes Ensure that the secondary partition is at least 10 GB as it is used to...

Страница 212: ...r upon process completion Execution OnExit 1 Shut down OSN server Set the OnExit parameter to 2 to shut down the OSN server upon process completion Execution OnExit 2 Notes The recommendation for this...

Страница 213: ...1 as shown below NetworkCardConfiguration EnableDhcp 1 This is only applicable if you have a DHCP server in your network Manually Static define IP address Set the EnableDhcp to 0 as shown below Networ...

Страница 214: ...is located on the USB dongle then see Section 29 9 3 on page 215 to define the directory path to where the image file is located Recovery partition Set Source to 4 as shown below ImageSource Source 4...

Страница 215: ...e i e ImageSource Source 3 as defined in Section 29 9 on page 214 then you must define the directory path to where the image file is located This is defined using the DOKsettings DirectoryPath paramet...

Страница 216: ...tal running of the SBA upgrade and recovery on your PC If not configured the procedure runs on any system User Confirm MacPrefix 00 45 B1 22 49 B1 You can define several MAC addresses by suffixing the...

Страница 217: ...llowing Contact your AudioCodes representative to verify if there are any required updates to the OSN s BIOS Enter the OSN server s BIOS setup and set the highest boot priority to the USB dongle and n...

Страница 218: ...OSN4 USB Port Figure 30 2 Plugging USB Dongle into OSN3 USB Port 4 Power off and then power on the Mediant 1000B chassis to boot the OSN server from the USB dongle the SBA upgrade and recovery process...

Страница 219: ...ngle from the USB port on the OSN module 7 Power off and then power on the Mediant 1000B to reboot the OSN server the initialization process starts Notes This step may take a while about 10 minutes Wh...

Страница 220: ...et the OnExit parameter to 2 so that the OSN server shuts down upon SBA upgrade and recovery completion Execution RecoveryStartType 0 Execution OnExit 2 2 Save and close the RecoveryUtil ini file 3 Co...

Страница 221: ...USB port on the USB hub 9 Power off and then power on the Mediant 1000B to reboot the OSN server the initialization process starts Notes This step may take a while about 10 minutes While the Mediant...

Страница 222: ...remote server cannot access the network or is not fully functional EMS provides a command line environment for managing a server through the out of band port The capability of redirecting text output...

Страница 223: ...t an RJ 45 cable connector not supplied to the RJ 45 serial port of the Mediant 1000B OSN3 and then connect the other end of the cable to the serial port of your PC Figure 30 7 Cabling OSN3 to PC for...

Страница 224: ...al window the following message is displayed Windows is loading files as shown in the figure below Figure 30 8 Windows Loading Files In a few moments the special administration console SAC prompt appe...

Страница 225: ...ge A new channel has been created is displayed type the following command SAC ch si 0001 where 0001 is the number of the created channel Figure 30 10 SAC Initialized The command console starts When th...

Страница 226: ...GoreCover The SBA Recovery and Upgrade process starts and logged messages are displayed in the console When the procedure completes successfully the following logged messages are displayed Figure 30...

Страница 227: ...Ethernet port All Network Interface Cards NIC are assigned IP addresses by your enterprise s DHCP server if it exists If you are not using a DHCP server you can assign a static IP address to this NIC...

Страница 228: ...ork cable connect the Ethernet port labeled on the OSN3 module to the network Figure 30 16 Connecting to LAN Port on OSN3 Module Rear Panel View 2 If you have an HDMI monitor connected do the followin...

Страница 229: ...work note the IP address assigned to the Ethernet LAN port If you are not using a DHCP server then assign a static IP address to the NIC of the Ethernet LAN port c Skip to Step 9 3 Connect your PC to...

Страница 230: ...n with OSN using a terminal emulation program such as HyperTerminal with the following port settings Bits per second 115200 Data bits 8 Parity None Stop bits 1 Flow control None 5 Press Enter the Seri...

Страница 231: ...etwork cable If you have a DHCP server in your network note the IP address of the relevant Ethernet port If you do not have a DHCP server in your network define the static IP address for the specific...

Страница 232: ...Welcome to SBA Screen 10 Log in with the default username Administrator and password Pass123 Select the Yes I accept the term and condition checkbox and then click Login the Home screen appears Figure...

Страница 233: ...4 Part VIII Appendices...

Страница 234: ......

Страница 235: ...WCF and Windows Workflow Foundation WF Application Server Foundation provides the means for delivering managed code applications with seamless user experiences secure communication and the ability to...

Страница 236: ...SCW Configuration and Analysis The server can be remotely configured analyzed or rolled back using the Security Configuration Wizard SCW user interface or command line tool Shadow Copies of Shared Fo...

Страница 237: ...S Client DNS clients also known as resolvers use the DNS Domain Name System protocol to send queries to DNS Servers to lookup the DNS name of a computer and retrieve information associated with the co...

Страница 238: ...ing user interfaces protect your customers personal identity information enable seamless and secure communication and provide the ability to model a range of business processes Local Application Insta...

Страница 239: ...Sends logging messages to the logging database when logging is enabled for the Active Directory Rights Management Services role If this service is disabled or stopped when logging is enabled logging...

Страница 240: ...If this service is disabled any services that explicitly depend on it will fail to start Manual Background Intelligent Transfer Service Transfers files in the background using idle network bandwidth...

Страница 241: ...pplication Manages the configuration and tracking of Component Object Model COM based components If the service is stopped most COM based components will not function properly If this service is disab...

Страница 242: ...eceive dynamic IP addresses and DNS updates If this service is disabled any services that explicitly depend on it will fail to start Automatic DHCP Server Performs TCP IP configuration for DHCP client...

Страница 243: ...on the local computer will start to see failures Automatic Encrypting File System EFS Provides the core file encryption technology used to store encrypted files on NTFS file system volumes If this se...

Страница 244: ...strators for the computer and users through the Group Policy component If this service is stopped or disabled the settings will not be applied and applications and components will not be manageable th...

Страница 245: ...anagement and Security Application using its locally available selected network interfaces Automatic Intel R Management and Security Application User Notification Service Intel R Management and Securi...

Страница 246: ...nd on it will fail to start Automatic KtmRm for Distributed Transaction Coordinator Coordinates transactions between the Distributed Transaction Coordinator MSDTC and the Kernel Transaction Manager KT...

Страница 247: ...e Shadow Copy Provider Manages software based volume shadow copies taken by the Volume Shadow Copy service If this service is stopped software based volume shadow copies cannot be managed If this serv...

Страница 248: ...Ethernet connection to the network If this service is disabled any services that explicitly depend on it will fail to start Automatic Network Store Interface Service This service delivers network noti...

Страница 249: ...n delivery Automatic Print Spooler Loads files to memory for later printing Automatic Problem Reports and Solutions Control Panel Support This service provides support for viewing sending and deletion...

Страница 250: ...System properties control panel item Automatic Remote Desktop Services UserMode Port Redirector Allows the redirection of Printers Drives Ports for RDP connections Manual Remote Desktop Services Conn...

Страница 251: ...service is disabled any services that explicitly depend on it will fail to start Automatic Secure Socket Tunneling Protocol Service Provides support for the Secure Socket Tunneling Protocol SSTP to c...

Страница 252: ...strongly recommended that you not disable the Software Protection service Automatic Special Administration Console Helper Allows administrators to remotely access a command prompt using Emergency Mana...

Страница 253: ...hony devices on the local computer and through the LAN on servers that are also running the service Manual TPM Base Services Enables access to the Trusted Platform Module TPM which provides hardware b...

Страница 254: ...color rendering Automatic Windows Driver Foundation User mode Driver Framework Manages user mode driver host processes Manual Windows Error Reporting Service Allows errors to be reported when programs...

Страница 255: ...r Automatic Windows Management Instrumentation Provides a common interface and object model to access management information about operating system devices applications and services If this service is...

Страница 256: ...notifications to index modified content If the service is stopped or disabled the Explorer will not be able to display virtual folder views of items and search in the Explorer will fall back to item b...

Страница 257: ...interfaces If your current wired network deployment enforces 802 1X authentication the DOT3SVC service should be configured to run for establishing Layer 2 connectivity and or providing access to netw...

Страница 258: ...ed in the SBA deployment These include the following Default SBA internal firewall rules see below SBA network firewall settings see Section A 6 2 Note Many firewall rules are required for normal SBA...

Страница 259: ...Allows DHCP Dynamic Host Configuration Protocol messages for stateful auto configuration UDP Inbound dhcp 68 67 Core Networking Dynamic Host Configuration Protocol DHCP Out Allows DHCP Dynamic Host Co...

Страница 260: ...remote LSASS traffic for Group Policy updates TCP TCP Outboun d lsass exe _ _ Core Networking Group Policy NP Out Core Networking Group Policy NP Out TCP Outboun d _ _ 445 Core Networking Group Policy...

Страница 261: ...ch is unable to forward the packet for any reason except congestion ICMP_V 6 Inbound _ _ _ Core Networking Multicast Listener Done ICMPv6 In Multicast Listener Done messages inform local routers that...

Страница 262: ...p membership ICMP_V 6 Inbound _ _ _ Core Networking Multicast Listener Query ICMPv6 Out An IPv6 multicast capable router uses the Multicast Listener Query message to query a link for multicast group m...

Страница 263: ...or in response to a Multicast Listener Query ICMP_V 6 Inbound _ _ _ Core Networking Multicast Listener Report v2 ICMPv6 Out Multicast Listener Report v2 message is used by a listening node to either...

Страница 264: ...request ICMP_V 6 Outboun d _ _ _ Core Networking Neighbor Discovery Solicitation ICMPv6 In Neighbor Discovery Solicitations are sent by nodes to discover the link layer address of another on link IPv...

Страница 265: ...ng Protocol Keyword ICMP_V6 Direction Inbound Packet Too Big error messages are sent from any node that a packet traverses which is unable to forward the packet because the packet is too large for the...

Страница 266: ...n ICMPv6 Out Router Solicitation messages are sent by nodes seeking routers to provide stateless auto configuration ICMP_V 6 Outboun d _ _ _ Core Networking Time Exceeded ICMPv6 In Time Exceeded error...

Страница 267: ...ut IGMP messages are sent and received by nodes to create join and depart multicast groups IGMP Outboun d _ _ _ Core Networking IPHTTPS TCP In Inbound TCP rule to allow IPHTTPS tunneling technology to...

Страница 268: ..._ _ _ Core Networking Teredo UDP In Inbound UDP rule to allow Teredo edge traversal a technology that provides address assignment and automatic tunneling for unicast IPv6 traffic when an IPv6 IPv4 ho...

Страница 269: ...t ICMPv4 Out Echo Request messages are sent as ping requests to other nodes Group File and Printer Sharing ICMP_V 4 Outboun d _ _ _ File and Printer Sharing Echo Request ICMPv6 In Echo Request message...

Страница 270: ...rule for File and Printer Sharing to allow NetBIOS Name Resolution UDP 137 UDP Inbound _ 137 _ File and Printer Sharing NB Session In Inbound rule for File and Printer Sharing to allow NetBIOS Session...

Страница 271: ...ing to allow Server Message Block transmission and reception via Named Pipes TCP 445 TCP Outboun d _ _ 445 World Wide Web Services HTTP Traffic In An inbound rule to allow HTTP traffic for Internet In...

Страница 272: ...ice to be remotely managed over Named Pipes TCP Inbound _ 445 _ Remote Administration RPC Inbound rule for all services to be remotely managed via RPC TCP TCP Inbound _ DynamicRPC _ Remote Administrat...

Страница 273: ...Inbound _ 445 _ Remote Event Log Management RPC EPMAP Inbound rule for the RPCSS service to allow RPC TCP traffic for the local Event Log Service TCP Inbound Rpcss RPCEndPoint Mapper _ Windows Firewa...

Страница 274: ...vschost 135 _ SCW inbound access firewall rule System TCP Allow inbound access for system using ports 139 445 and protocol TCP TCP Inbound _ 139 445 _ SCW remote access firewall rule System UDP Allow...

Страница 275: ...Ports Windows Communication Foundation Net TCP Listener Adapter TCP In An inbound rule for Windows Communicati on Foundation to allow TCP traffic to the Net TCP Listener Adapter TCP 808 TCP Inbound n...

Страница 276: ...alized Logging Service Front End Servers SBA 50003 TCP SIP MTLS Centralized Logging Service Front End Servers SBA 5090 TCP SIP MTLS WinFabFederationPort Front End Servers SBA 5091 TCP SIP MTLS WinFabL...

Страница 277: ...2 TCP SIP MTLS WinFabClientConnectionP ort SBA Front End Servers 5093 TCP SIP MTLS WinFabIPCPort SBA Front End Servers 5094 TCP SIP MTLS WinFabReplicationPort SBA Director 444 TCP HTTPS Certificate re...

Страница 278: ...Installation Maintenance Manual 278 Document LTRT 40111 Mediant 1000B SBA This page is intentionally left blank...

Страница 279: ...Virus Software When Anti Virus software is run on SBA components ensure that the Antivirus file scanning exclusions are based on the following Microsoft recommendations SBA 2010 https technet microso...

Страница 280: ...Installation Maintenance Manual 280 Document LTRT 40111 Mediant 1000B SBA This page is intentionally left blank...

Страница 281: ...e inserted and extracted without disrupting other non related OSN services running on the device Therefore you can insert and replace the OSN modules without powering down the device C 1 Verifying the...

Страница 282: ...AudioCodes sales representative To upgrade to an SBA gateway 1 Remove the new OSN server modules from their ESD shielding packets in which they were shipped 2 Install the HDMX module a Remove the bla...

Страница 283: ...ng it along the slot s guide rails until it makes contact with the card edge connector located on the backplane Figure C 2 Installing OSN Module c Push the module s handle until it clicks firmly into...

Страница 284: ...pull the HDMX module s handle until you hear the first click sound the handle is now partially pulled out and the module undergoes a shutdown sequence indicated by the slow flashing Hot Swap Blue LED...

Страница 285: ...the module undergoes a reset indicated by the Hot Swap Blue LED switching off Figure C 4 OSN Module Reset 5 Reset the SBA account on the Active Directory as shown in the screen example below Figure C...

Страница 286: ...o M1KB SBA ES EO 1 Shutdown the SBA server see Section 11 19 2 on page 139 2 Remove the HDMX from Slot 1 a Gently pull the HDMX module s handle until you hear the first click sound the handle is now p...

Страница 287: ...ted on the backplane Figure C 6 Replacing HDMX Module b Push the module s handle until it clicks firmly into the slot 5 Insert the new OSN3B or OSN4 module into Slot 2 a Hold the new OSN module in the...

Страница 288: ...in the screen example below Figure C 8 Reset SBA Account 7 Install the SBA application on the OSN platform using the supplied USB Upgrade and Recovery dongle see Chapter 30 on page 217 8 Connect to t...

Страница 289: ...n sequence indicated by the slow flashing Hot Swap Blue LED on the module b When the LED stops flashing and is constantly lit indicating that the shutdown sequence is complete disconnect any cables th...

Страница 290: ...Installation Maintenance Manual 290 Document LTRT 40111 Mediant 1000B SBA This page is intentionally left blank...

Страница 291: ...uration as described in Chapter 11 on page 79 Ensure that the HDMX disk in Slot 8 slave is unallocated without a volume allocated Ensure that the storage capacity of both the HDMX disks is identical e...

Страница 292: ...th ES D 3 Configuring RAID 1 The procedure below describes how to configure RAID 1 on the Mediant 1000B SBA Note As this is an uptime solution i e it allows you to plan the installation and keep the S...

Страница 293: ...ation Maintenance Manual D Configuring RAID Version 6 8 293 Microsoft Lync Server Figure D 3 Computer Management 3 In the Server Manager navigate to the Disk Management menu option Figure D 4 Disk Man...

Страница 294: ...Maintenance Manual 294 Document LTRT 40111 Mediant 1000B SBA 4 Convert the disks to Dynamic by right clicking Disc 0 and then selecting the Convert to Dynamic Disk menu option Figure D 5 Convert to D...

Страница 295: ...nc Server 5 Select one or more basic disks to convert to dynamic disks and then click OK Figure D 6 Convert to Dynamic Disk Selection 6 In the Disks to Convert screen click Convert Figure D 7 Disks to...

Страница 296: ...nt LTRT 40111 Mediant 1000B SBA 8 Add the Mirror by right clicking Partition C and then select the Add Mirror menu option Figure D 9 Add Mirror 9 Select a location for a mirror of Disk C and then clic...

Страница 297: ...sion 6 8 297 Microsoft Lync Server 10 The Add Mirror process appears displaying progress in the Status column Figure D 11 Disk Management Resynching 11 When the process has completed the following scr...

Страница 298: ...SBA Installation and Maintenance Manual www audiocodes com www audiocodes com...

Отзывы: