Survivable Branch Appliance
AudioCodes Enhanced Media Gateway
112
Document #: LTRT-18206
5.2.4
Step 4: Configure SIP TCP Transport Type and Fax Signaling Method
This step describes how to configure the fax signaling method for MP-11x.
¾
To configure the fax signaling method:
1.
Open the 'SIP General Parameters' page (
Configuration
tab >
Protocol Configuration
menu >
Protocol Definition
submenu >
SIP General Parameters
).
Figure
5-16: SIP General Parameters Page
2.
From the ‘FAX Signaling Method’ drop-down list, select
‘G.711 Transport’
.
3.
From the ‘SIP Transport Type’ drop-down list, select
‘TCP’.
4.
In the ‘SIP TCP Local Port
’
field, enter
‘5068’
(corresponding to the Central Gateway TLS
transmitting port configuration).
5.
In the ‘SIP Destination Port’, enter
‘5067’
(corresponding to the Central Gateway TLS
listening port configuration).