TxRx
Rx
Tx
BAtt
2.7 v
H
•
Align the front of the Switch
iR with the infra-red port on
the receiver and press
OK
. The display will show the DC
voltage:
TxRx
Rx
Tx
BAtt
2.7 v
H
If the associated transmitter is on while the DC status
is being checked the display will alternate between the
receiver’s DC status and the received transmitter DC
status. For example:
TxRx
Rx
Tx
BAtt
2.7 v
H
The transmitter status is shown as one of the following
options:
External powering
Audio Ltd has a large selection of cables available for a
variety of different applications. If the DX2040 receiver is
to be externally powered, ensure that the appropriate cable
is used.
Technical specification
User Guide
DX2040 True Diversity Receiver
Frequency range
470MHz–1000MHz
Number of frequencies
32 pre-programmed
Switching bandwidth
Up to 24MHz
Sensitivity
-98dBm for 40dB SINAD
Balanced output level
-25dBu
Frequency response
50Hz to 18kHz ±1dB
THD
<0.2% typical
Batteries
2 x 1.5V AA (LR6) type
Battery life
> 4 hours on good alkaline batteries
Size
147 x 64 x 20mm
Weight
250g
Operating temperature range
-20°C to +55°C
Compliant to
ETS 300422 EN 300445(CE) FCC
OPTION
DESCRIPTION
H (high)
Indicates good.
L (low)
Indicates low. Replace as soon
as possible.
F (failed)
Transmitter will not function
correctly.
For further information contact Audio Ltd or your local distributor
www.audioltd.com