Safety Cautions

Prior to use of this product, review all safety markings and instructions.

To prevent electric shock, do not remove the cover. There are no user-serviceable parts inside.
Internal adjustments are for qualified professionals only. Refer all servicing to qualified ser-
vice personnel.

Pour prévenir un choc électrique, ne pas ouvrir le couvercle. Il n’y aucune pièces de rechanges
à l’intérieur. Tout ajustement interne doit être fait par une personne qualifié seulement.
Référez tout réparation au personnel qualifié.

Warning: This apparatus must be grounded.

This product is a safety class 1 product. There must be an uninterruptible safety earth ground
from the main power source to the product’s AC input. Whenever it is likely that the protection
has been impaired, disconnect the power cord until the ground has been restored.

Attention: Cet appareil doit être mise à la terre.

Cet appareil est de classe de sûreté 1. Il doit y avoir un ininterrompable de mise à la terre de
sécurité provenant de la source principale de courant de l’appareil de l’entrée du courant alter-
natif. Quand la protection a été affaiblie, débrancher le fil de courant jusqu’à la mise à terre 
a bien été réétablie.

Caution/Avis:

To prevent fire or shock hazard, do not expose this appliance to rain or moisture.
Pour prévenir feu ou choc électrique, ne pas exposé l’appareil à la pluie ou à l’humidité.

Caution/Avis:

For continued protection against fire hazard, replace only with same type/rating of fuse.
Pour poursuivre la protection contre le feu, replacez la fusible de même type/cote.

Warning/Attention:

There are some sharp edges inside. To reduce the risk of injury, do not remove cover.
Bord tranchant à l’intérieur. Pour réduire le risque de blessure, ne pas ouvrir le couvercle.

Note: Line Voltage Selector Switch

You will find the line voltage selector switch on the bottom panel. Before your model is shipped
from the factory, the switch is set to the power requirements of the destination. Nevertheless,
you should check that it is set properly before plugging the power cord into the wall outlet. If
the voltage requirements differ, adjust the selector switch as follows. Before adjusting, discon-
nect the power cord.

1. Provide yourself with a medium size screwdriver.

2. Change the position of  switch to the proper voltage for your area.

Do not expose this apparatus to drips or splashes.
Do not place any objects filled with liquids such as vases on the apparatus.
Do not install this apparatus in a confined space such as a bookcase or similar unit.
The apparatus should be located close enough to the AC outlet so that you can easily grasp 
the power cord plug at any time.

4

CAUTION

AVIS

RISK OF ELECTRIC SHOCK

RISQUE DE CHOC ÉLECTRIQUE

DO NOT OPEN

NE PAS OUVRIR

Содержание SmartMixer AT-MX351

Страница 1: ...AT MX351 SmartMixer Automatic Mixer Installation and Operation ...

Страница 2: ......

Страница 3: ...r FCC You are cautioned that any changes or modifications not expressly approved in this manual could void your authority to operate this equipment Note This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is oper...

Страница 4: ...e to rain or moisture Pour prévenir feu ou choc électrique ne pas exposé l appareil à la pluie ou à l humidité Caution Avis For continued protection against fire hazard replace only with same type rating of fuse Pour poursuivre la protection contre le feu replacez la fusible de même type cote Warning Attention There are some sharp edges inside To reduce the risk of injury do not remove cover Bord ...

Страница 5: ...s ensures proper gating levels for existing ambient sound conditions Priority Pre select To custom tailor conferencing needs the mode of each microphone channel can be indepen dently switched via the front panel Priority Pre select DIP switches The combination of switch settings results in three different modes of priority selection operation In any of the three modes of operation when everyone st...

Страница 6: ... 1 4 A switch in the up position assigns the respective channel priority over the other channels A priority channel can not be locked out by other channels Any combination of priority non priority selections is allowed 8 Manual mode switch Setting this switch in the up position bypasses all of the SmartMixer s automatic functions except limiting and NOMA if selected 9 Lockout LED indicator Shows w...

Страница 7: ...evel 10 dBV auxiliary input 6 Preamp Outputs Independent unbalanced 10 dBV switchable pre post controller outputs from mic channels 7 Inputs Balanced microphone inputs for low impedance dynamic or condenser mics Can be changed to line level inputs via internal switches see page 10 XLRF type connectors Can supply 48V phantom power via internal switches 8 Power input 120V 230V AC 50 60 Hz Select inp...

Страница 8: ...e the unit will behave like a conventional mixer all automatic functions are bypassed except for limiting and NOMA if selected 11 Adjust the Master level control for desired output level This control is at the last stage in the mixer and does not affect microphone gain threshold setting meter indication monitor or preamp outputs Priority Microphones and the Lockout Bus Channels 1 4 Once the Gain c...

Страница 9: ...f position To turn on the NOMA function unplug the unit remove the top cover and change the setting of the switch designated on the circuit board by SW25 Figs 4 and 5 page 11 NOMA serves to maintain overall system gain by proportionately reducing amplifier gain as the number of open microphones increases In a sound reinforcement system this can tend to preserve the feedback margin and system stabi...

Страница 10: ...the circuit board by SW1 SW7 SW13 and SW19 Figs 4 and 5 page 11 Changing the settings of these switches will disable phantom power on channels 1 2 3 and 4 respectively Note that although they do not require phantom power for operation most balanced output dynamic microphones can be used without disabling the SmartMixer s phantom power Output Level LED Meter The Output Level LED meter is factory se...

Страница 11: ...1 0 dB 10 dB VR2 1 0 dB 10 dB VR2 1 0 dB 10 dB VR5 1 0dB 10dB VR8 1 0dB 10dB VR1 1 Phantom Of f SW1 30 dB SW2 40 dB Phantom Of f SW7 30 dB SW8 40 dB Phantom Of f SW13 30 dB SW14 40 dB Phantom Of f SW19 30 dB SW20 40 dB SW22 Of f O n SW4 Of f O n SW10 Of f O n SW16 Of f O n SW27 Pe ak RMS Meter Of f On SW25 NOMA Line Mic Outpu t SW26 Mic Line SW9 Mic Line SW1 5 Mic Line SW21 SW6 SW12 SW18 SW2 4 Gat...

Страница 12: ...To gate these outputs unplug the unit remove the top cover and locate the switches designated on the circuit board by SW6 SW12 SW18 and SW24 Figs 4 and 5 page 11 Change the switch position s to Gating for channels 1 2 3 and or 4 respectively as desired Input Limiters Independent adjustable limiters are available on all mic channels To adjust the limiter threshold of channel 1 unplug the unit remov...

Страница 13: ...l LED on the front panel the channel s associated Control Voltage Out goes high 4 VDC See chart on page 12 for pin connection This signal can be used to light indicator lamps switch speaker zones on and off select video cameras etc The control voltage should not be connected directly to an inductive load such as a relay coil as damage to the mixer may result Several interface circuit possibilities...

Страница 14: ... linked with AT MX341 and or AT MX341a mixers the NOMA function will pass through the AT MX341 a models but their mics will not be included in the NOMA calculation Rack Mounting Provided with each mixer are two rack ears and six self tapping screws to attach the ears to the unit which allow the unit to be mounted in a 1U rack space Security Caps For permanent installations where microphone selecti...

Страница 15: ...put Noise1 128 dBV 150 ohms at maximum gain Input Attenuation 10 dB Mic Line Input Pads 50 dB Maximum NOMA Attenuation 20 dB up to 100 mics on simultaneously Microphone Phantom Power 48V DC Control Voltage Out 4V DC Power Supply 120V 230V AC switchable 50 60 Hz 10W Operating Temperature 32 to 104 F 0 to 40 C Dimensions 16 93 430 mm W x 9 38 327 mm D x 1 75 44 mm H including feet knobs and connecto...

Страница 16: ...or failure to use product in accordance with instructions This warranty is void in the event of unauthorized repair or modification For return approval and shipping information contact the Service Department Audio Technica U S Inc 1221 Commerce Drive Stow Ohio 44224 Except to the extent precluded by applicable state law A T U S will have no liability for any consequential incidental or special dam...

Отзывы: