Setting ATW-R5220/ATW-R5220DAN

Setting the audio output level

1.  From the menu screen, turn the control dial, select [AUDIO] and 

then press the control dial.

2.  Turn the control dial to set the audio output level.

•  The level changes 2dB +/- each time you turn the control dial.

•  It can be set from -60 to 0dB.

3.  Press the control dial.

•  The setting is complete.

Scanning for open channels

Scan for unused channels in the current environment for use.

1.  From the menu screen, turn the control dial, select [SCAN] and 

then press the control dial.

2.  Turn the control dial to select the group you want to scan. After 

selecting a group, press the control dial.

•  Selecting "ALL" will scan all the groups.

3.  Turn the control dial to select the preferred threshold. selecting 

the threshold, press the control dial.

•  You can select [Normal], [High] or [Low] sensitivity.

High: Prioritize the number of channels.

Normal

Low: Prioritize stable operation.

•  Scan starts.

Selecting [ALL]:

4.  Confirm the scan result, select the group and then press the 

control dial.

5.  Select the channel selection method, and them press the control 

dial.

•  When selecting [Manual] and pressing the control dial, available channels 

and frequencies are shown in a list. Turn the control dial, select an 
available channel and then press the control dial. The setting is complete.

•  When selecting [Find Best] and pressing the control dial, the optimum 

channel and frequency are shown. Turn the control dial, select [Set] and 
then press the control dial. The setting is complete.

Selecting the group you want to scan:

4.  Confirm the scan result by selecting [OK] and then pressing the 

control dial.

•  If you want to scan over again, select [Retry].

5.  Select the channel selection method, and them press the control 

dial.

•  When selecting [Manual] and pressing the control dial, available channels 

and frequencies are shown in a list. Turn the control dial, select an 
available channel and then press the control dial. The setting is complete.

•  When selecting [Find Best] and pressing the control dial, the optimum 

channel and frequency are shown. Turn the control dial, select [Set] and 
then press the control dial. The setting is complete.

Setting transmitters via IR SYNC

This function allows you to make transmitter settings on the receiver 
and then automatically configure the transmitter via IR SYNC. The 
following are the available settings and setting values:

Settings

Setting values

Freq

Current setting value, NoChange

Name

Current setting value, NoChange

RF Pwr

Low:2mW, Mid:10mW, High:50mW, NoChange

Gain

-10 to +20dB, NoChange

Sens.*

0, +10dB, NoChange

Lock

Lock, Unlock, NoChange

Batt

Alkaline, Ni-MH, NoChange

HPF

OFF, ON, NoChange

* ATW-T5201 only

1.  From the menu screen, turn the control dial, select [TX SYNC] 

and then press the control dial.

2.  Turn the control dial to select a setting you would like to sync to 

the transmitter and then press the control dial.

3.  Turn the control dial to select the setting value and then press 

the control dial.

4.  Repeat Steps 2 and 3 for each setting you would like to sync to 

the transmitter.

5.  Turn the control dial, select [SYNC START] and then press the 

control dial.

•  Communication function is in standby. Refer to "Using IR SYNC" (p. 28) 

for subsequent steps.

Содержание ATW-R5220

Страница 1: ...User Manual UHF Wireless Systems ATW R5220 Dual Receiver ATW R5220DAN Dual Receiver with Dante Output ATW T5201 Body Pack Transmitter ATW T5202 Handheld Transmitter without capsule 5000 Series ...

Страница 2: ...annels 17 Setting transmitters via IR SYNC 17 Setting the squelch level 18 Setting the system related functions 18 Setting network 21 Using test mode 22 Setting DANTE 22 Settting ATW T5201 ATW T5202 23 List of setting items 23 Setting the transmission frequency 23 Setting the channel transmitter name 23 Setting the gain 24 Setting the microphone input gain 24 Setting the RF transmission output 24 ...

Страница 3: ...pparatus should not be placed near to other electrical apparatuses Keep the top and sides of this apparatus at least 10 mm away from any other surface if sitting on shelving such as an audio apparatus rack Failure to do so may cause this apparatus to overheat which in turn may cause it or surrounding items to catch fire Battery caution Keep batteries out of the reach of children Observe correct po...

Страница 4: ...cause undesired operation Caution You are cautioned that any changes or modifications not expressly approved in this manual could void your authority to operate this equipment Wireless microphone users shall rely on the white space databases in part 15 Subpart H to determine that their intended operating frequencies are available for unlicensed wireless microphone operation at the location where t...

Страница 5: ...duce unwanted noise If this occurs move the product away from the device When setting up the product make sure there are no obstacles between the transmitter and the receiver that might block the signal To prevent the batteries from wearing out turn the transmitter off when not in use Over time discoloration may occur due to ultraviolet rays especially direct sunlight and friction It is legally pr...

Страница 6: ...rns to the Main screen when pressed and held Control dial Displays the setting menu when you press the dial Turn the dial to select a setting and press to confirm When you press and hold the dial TX SYNC setting screen is displayed Headphone monitor 6 3 mm output jack This is the headphone output jack used for monitoring It allows you to monitor receivers 1 and 2 Headphone channel indicator Displa...

Страница 7: ...witch This switch isolates the GND pin of the balanced unbalanced output from the ground Normally this is kept in the GND position but if a hum develops due to a ground loop switch to the LIFT side Balanced output jack XLR 3 pin male GND HOT COLD Network interface By connecting to a PC via Ethernet you can use the PC for monitoring or control In the case of ATW R5220DAN it will be the DANTE output...

Страница 8: ... output Pin 2 Instrument input Pin 3 Microphone input Display Shows the current status If no buttons are pressed for a period of 30 seconds the display will turn off BACK button Press to take the display back one screen Returns to the Main screen when pressed and held Lever push switch Use to select various settings UP Turn to the right to change a selection DOWN Turn to the left to change a selec...

Страница 9: ...ssed and held IR sync window Use to IR SYNC with the receiver DOWN button Used for selecting various settings SET button Press to confirm a selection SYNC button Use to IR SYNC with the receiver ATW R5220 ATW R5220DAN Power switch Use to turn the power on or off Battery cover Function button Press briefly to turn the screen back on if it shuts off Press and hold to perform preselected function Ind...

Страница 10: ...e battery cover 4 Insert the batteries according to the plus and minus marks found inside the battery compartment ATW T5202 1 Rotate the grip case of the battery compartment 2 Open the battery cover Put your finger on the hook of the battery cover and pull it to open the battery cover 3 Insert the batteries according to the plus and minus marks found inside the battery compartment ...

Страница 11: ...tighten it How to remove 1 Rotate the microphone capsule counterclockwise to loosen it 2 Detach the microphone capsule from the body of the transmitter Do not directly touch or scratch the connection surface Be sure to turn off the power of the transmitter before attaching detaching the microphone capsule Do not forcibly attach the microphone capsule Doing so may damage the transmitter or micropho...

Страница 12: ...level indicator Displays the strength of the received audio signal Group indicator Channel indicator Backup frequency indicator BU icon is displayed when the backup frequency mode is ON Lock status indicator Antenna input power indicator Icon is displayed when the antenna power supply is ON Transmitter information display area TX HPF 30mW TX MUTE TX Normal Muted Non communication Lock status indic...

Страница 13: ...witching between screens The screen is switched every time the function button 1 is pressed B RF TX AF A 30mW TX RF PWR 92 40 30 24 18 15 12 10 8 6 4 2 0 2 4 6 dBu 86 80 74 dBm RX 12 dB 10 dB OL TX HPF B RF AF BU 0 000 000 VOCAL1 MHz A 30mW Gr 06 Ch 12 Main screen B RF TX AF A 30mW TX RF PWR 92 40 30 24 18 15 12 10 8 6 4 2 0 2 4 6 dBu 86 80 74 dBm RX 12 dB 10 dB OL Level meter screen RF transmissi...

Страница 14: ...or Displays the set frequency Lock status indicator Battery level indicator 75 or more battery power remaining 50 to 75 battery power remaining 25 to 50 battery power remaining 25 or less battery power remaining Flicker Replace the batteries RF transmission output indicator RF Power High 50mW RF Power Mid 10mW RF Power Low 2mW RF OFF RF Power Off High pass filter indicator Name display Displays th...

Страница 15: ...display shows the main screen ATW T5201 ATW T5202 5 Set the transmission frequency 6 Check the RF level indicator on the receiver Check that antenna A or B lights up 7 Speak into the microphone Make sure the AF level indicator lights up on the receiver Using SYNC shortcut You can easily move to the setting screen that you can set the settings of the receiver with SYNC shortcut 1 Press and hold for...

Страница 16: ...W T5202 UP DOWN button operation is explained below In this user manual the text is indicated as the button operation ATW T5201 Slide to the UP DOWN position ATW T5202 Press the UP DOWN button 1 Press the SET button The menu screen appears ATW T5201 ATW T5202 2 Press the UP DOWN button to select the item you wish to set 000 MHz 000 FREQUENCY Selected menu item Current setting value 3 Press the SET...

Страница 17: ... and channel label IP SETTING Set the DANTE s IP MAC ADDRESS Display the MAC address VERSION This function displays product information such as the version of the receiver ATW R5220DAN only Setting the operating frequency Manual setting 1 From the menu screen turn the control dial select FREQUENCY and then press the control dial 2 Select MANUAL and press the control dial 3 Turn the control dial to...

Страница 18: ...ete Selecting the group you want to scan 4 Confirm the scan result by selecting OK and then pressing the control dial If you want to scan over again select Retry 5 Select the channel selection method and them press the control dial When selecting Manual and pressing the control dial available channels and frequencies are shown in a list Turn the control dial select an available channel and then pr...

Страница 19: ...he transmitter becomes wider as the squelch level is lower there may be cases when noises occur under the influence of other radio waves While the available range of the transmitter becomes narrower as the squelch level is made higher noises are less likely to occur due to the less influence of other radio waves 4 Press the control dial The setting is complete Setting the system related functions ...

Страница 20: ...ol dial select UTILITIES and then press the control dial 2 Turn the control dial select Gr Ch EDIT and then press the control dial 3 Turn the control dial select Gr Ch SYNC and then press the control dial 4 Turn the control dial to select group and then press the control dial The screen turns to an IR SYNC standby screen Refer to Using IR SYNC p 28 for subsequent steps Setting the backup frequency...

Страница 21: ... is Free Tuning 1 From the menu screen turn the control dial select UTILITIES and then press the control dial 2 Turn the control dial select ACCESS and then press the control dial 3 Turn the control dial select Free Tuning or Group Only and then press the control dial Free Tuning No limit Group Only Selection of frequency can be made only from group The setting is complete Resetting This returns t...

Страница 22: ...IP Set the address for multicast Multicast Port Set the port number for multicast 4 Set each item Setting the log message Set whether to send the log message to the Syslog server 1 From the menu screen turn the control dial select NETWORK and then press the control dial 2 Turn the control dial select SYSLOG and then press the control dial 3 Turn the control dial select ON or OFF and then press the...

Страница 23: ...g the device name and channel label 1 From the menu screen turn the control dial select DANTE and then press the control dial 2 Turn the control dial select INFO Setting the DANTE s IP 1 From the menu screen turn the control dial select DANTE and then press the control dial 2 Turn the control dial select IP SETTING and then press the control dial 3 Select an item you want to set and press the cont...

Страница 24: ...P DOWN button to set the last 3 digits After completing the setting press the SET button The setting is complete Setting by group channel 1 From the menu screen press the UP DOWN button to select FREQUENCY and then press the SET button 000 MHz 000 FREQUENCY 2 After selecting Gr Ch press the SET button Gr Ch FREQUENCY 3 Press the UP DOWN button to set the group After completing the setting press th...

Страница 25: ... is complete Setting the RF transmission output 1 From the menu screen press the UP DOWN button to select RF POWER and then press the SET button High 50mW RF POWER 2 Press the UP DOWN button and select High 50mW Mid 10mW Low 2mW or Off 3 Press the SET button The setting is complete Setting HPF High Pass Filter 1 From the menu screen press the UP DOWN button to select HPF and then press the SET but...

Страница 26: ...he UP DOWN button to select TOOLS and then press the SET button TOOLS 2 Press the UP DOWN button to select TEST TONE and then press the SET button Off TEST TONE 3 Press the UP DOWN button to select On and then press the SET button Outputting a test signal starts While outputting a test signal a microphone input will be muted Setting the system related functions Setting the battery type Set the typ...

Страница 27: ... button to select Free or Group Free No limit Group Selection of frequency can be made only from group 4 Press the SET button The setting is complete Resetting This returns the transmitter settings to their factory defaults 1 From the menu screen press the UP DOWN button to select UTILITIES and then press the SET button UTILITIES 2 Press the UP DOWN button to select RESET and press the SET button ...

Страница 28: ...clip in the opposite direction Pull both sides of the clip firmly to the outside to remove the clip from the transmitter Making connections basic connections This is an example of connections made when using one receiver When connecting more than one receiver via a distributor sold separately refer to the distributor s user manual Whip antenna Whip antenna Power cable To computer or DANTE device M...

Страница 29: ... the transmitter If an error occurs in the SYNC process an error screen opens and then the display returns to the menu screen Check the IR SYNC windows of the receiver and transmitter and then SYNC again To cancel the SYNC process press the BACK button on the receiver You will be returned to the previous screen Achieving stable reception Low RF signal may result if there are obstructions between r...

Страница 30: ...g used by another noisy component Confirm that there isn t any other nearby wireless system using the same frequency band Adjust the squelch level p 17 ATW T5201 ATW T5202 Symptoms Causes and countermeasures Reference page The power can t be turned on Confirm that batteries are in place Confirm that batteries are not depleted Confirm that batteries are inserted in the right direction p 8 There is ...

Страница 31: ...30 Unit mm Dimensions ATW R5220 ATW R5220DAN 482 0 400 0 32 8 43 0 361 0 ...

Страница 32: ...31 Unit mm Unit mm Dimensions ATW T5201 ATW T5202 193 0 Φ 37 64 0 70 0 17 0 ...

Страница 33: ... ATW R5220 ATW R5220DAN Receiving system True diversity Image rejection 80 dB nominal RF sensitivity 18 dBuV at 60 dBA S N ratio 50 ohms termination Maximum output level XLR Balanced 18 dBV Headphone output connector 6 3 mm 1 4 TRS Stereo Headphone output power 180 mW typical Antenna input BNC type 50 ohms Antenna power 12 V DC 150 mA combined Power supply 100 to 240 V AC 50 60 Hz Operating temper...

Страница 34: ...sule 193 mm 7 60 long 37 mm 1 46 maximum diameter ATW T5202 C510 265 mm 10 43 long 54 mm 2 13 maximum diameter ATW T5202 C710 271 mm 10 67 long 50 mm 1 97 maximum diameter Weight without batteries ATW T3202 without capsule 200 g 7 1 oz ATW T5202 C510 330 g 11 6 oz ATW T5202 C710 314 g 11 1 oz Operating temperature range 5 ºC to 40 ºC 23 º F to 104 ºF Included accessories AT8456a Quiet Flex stand c...

Страница 35: ... Technica Corporation 2 46 1 Nishi naruse Machida Tokyo 194 8666 Japan www audio technica com 2018 Audio Technica Corporation Global Support Contact www at globalsupport com ver 1 2018 08 01 232417000 02 01 ...

Отзывы: