74
Error messages
Error Message
Cause
Action
Resume Data Error
Importing the resume data failed.
The product started with the previous or default settings.
Restart the product, and check whether the same error occurs.
Preset Data Error
Importing the preset data failed.
The preset data is the one that was successfully imported
last time or the default.
Restart the product, and check whether the same error occurs.
Library Data Error
Importing the EQ library data failed.
The product started with the previous or default settings.
Restart the product, and check whether the same error occurs.
Audio-Technica LINK Connection Error
An error occurred during the communication with an ATDM-
0604 that is connected via Audio-Technica LINK.
The operation of Audio-Technica LINK was stopped.
Check for any network connection problem.
Audio-Technica LINK OFF
The Audio-Technica LINK was canceled, and its operation
was stopped.
Check for any network connection problem.
Detect Exceeded Link Units
The number of ATDM-0604 units connected exceeded the
maximum number of units that can be connected.
The operation of Audio-Technica LINK was stopped.
Check the number of units connected.
Detect Multi Primary Units
More than one primary unit of ATDM-0604 were detected.
The operation of Audio-Technica LINK was stopped.
Set only one ATDM-0604 unit as the primary.
Detect Ring Connection
A ring connection was detected.
The operation of Audio-Technica LINK was stopped.
Do not connect units in a ring pattern. Make sure to leave
one of the two LINK terminals at both ends of the connected
ATDM-0604 devices open.
Network Communication Error
A network communication error occurred.
Check for any network connection problem.
An IP command communication error occurred.
Access from Non Permitted Device
A device not permitted to access was connected.
Check for any network connection problem.
File Import Failed
Importing the preset file failed.
• Check whether the file format is correct.
• The network connection may have been disconnected.
File Export Failed
Exporting the preset file failed.
The network connection may have been disconnected.
Failed
An unknown system failure occurred.
Perform the operation again, and check whether the same error
occurs.
Failed. Please turn power OFF.
An error occurred during the firmware update.
Restart the product, and check whether the same error occurs.
Data acquisition error.
Acquisition of data via web remote failed.
Perform the operation again, and check whether the same error
occurs.
USB Disconnected
The USB connection with the PC is not established.
• Check whether the USB connection with the PC is proper.
• Connect the USB to another PC, and check whether the
same error occurs.
Synchronous Disconnect
Synchronization with the PC failed.
• Check whether the USB connection with the PC is proper.
• Connect the USB to another PC, and check whether the
same error occurs.
Cannot COPY
The data cannot be copied because the EQ preset is full.
Check whether there is space in the EQ preset.
Copying of the bands in static state to the 12-band EQ
failed.
The bands for which EQ is set to OFF on the 12-band EQ side
are to be copied. Check the settings.
Cancel Time is not enough.
The result of the reverberation measurement is 160 ms or
longer.
The screen prompts to confirm whether or not to change
the AEC response to LOW. Check the settings based on the
instructions on the screen.
AEC doesn't work
AEC is not functioning properly.
Check the AEC settings.
Time out Error.
A time out error occurred during an AEC reverberation
measurement.
Perform the measurement again.
Содержание ATDM-0604
Страница 1: ...ATDM 0604 User Manual DIGITAL SMARTMIXER ...
Страница 76: ...75 Dimensions 6 2 326 0 13 5 44 0 217 0 Unit mm ...