background image

4

2.2 Image of Effective Infrared Range of IRA

NOTICE

· Infrared transmissions cannot reach the IRA if they are hidden or blocked by users.
· Install multiple IRAs so they can be seen from the IRDUs
· Do not cover the infrared transmitter with your hand or anything else.

2.3 Image of Effective Infrared Range of IRDU

IRA

PUSH

Содержание ATCS-B60

Страница 1: ...rophone with LED Ring ATUC M43H 58H M32L IR Discussion Unit ATUC IRDU Hybrid Control Unit ATUC IRCU Hybrid Control Unit Dante Enabled ATUC IRCUDAN IR Transmitter Unit ATUC IRA IR Distributor ATUC IRD Charger ATCS B60 Instruction Manual Installation Edition ...

Страница 2: ...s Do not place any obstacles around the IRDUs Do not exceed 100 meters for the total length of cable connections When installing multiple IRAs use the same length for the total length of each of the cables from the IRAs to the IRCU IRCUDAN We recommend a difference of less than 3 m Contact our sales representative if you are going to use multiple monitor channels at the same time 1 Confirming the ...

Страница 3: ...Rotate Insert 1 1 Names of IRA Parts Power LED Lights when the power to the IRCU is on after wiring is complete Hook for mounting Use to mount on the mounting bracket included accessory BNC connector BNC cables are not included accessories Checkpoints Width length ceiling height existence of windows etc Does construction of the ceiling allow for installation ceiling surface existence of space abov...

Страница 4: ...hen mounting IRA on a ceiling 2 1 Relationship Between Ceiling Height and Transmission Area for Ceiling Installation of IRA 2 4 m 2 7 m 3 m 4 m 5 m 6 m Approximately φ 5 m Approximately φ 6 m Approximately φ 7 m Approximately φ 7 m Approximately φ 7 m Approximately φ 5 m Transmission Area Elevation Diagram ...

Страница 5: ...ared transmissions cannot reach the IRA if they are hidden or blocked by users Install multiple IRAs so they can be seen from the IRDUs Do not cover the infrared transmitter with your hand or anything else 2 3 Image of Effective Infrared Range of IRDU IRA PUSH ...

Страница 6: ...ositions contact our sales representative 3 1 Images of Installations in U Shapes and Square Shapes The following diagram shows a square shape 3 2 Images of Installations in School Formats Checkpoints Confirm operating format U shape square shape school format etc Distance between and orientation of IRDUs and IRAs 12 m 10 m IRA IRDU 15 m 12 m ...

Страница 7: ...on Examples Round table W 10 m D 8 m H 2 4 m transmission area approximately φ5 m 10 m 8 m Ceiling height 2 4 m Square shape small W 12 m D 8 m H 2 4 m transmission area approximately φ5 m 12 m 8 m Ceiling height 2 4 m ...

Страница 8: ...ape large W 15 m D 12 m H 2 7 m transmission area approximately φ6 m 15 m 12 m Ceiling height 2 7 m U shape back area seats W 15 m D 12 m H 2 4 m transmission area approximately φ5 m Ceiling height 2 4 m 15 m 12 m ...

Страница 9: ...esks W 18 m D 12 m H 2 7 m transmission area approximately φ6 m 18 m 12 m Ceiling height 2 7 m Long U shape desks on both sides W 18 m D 12 m H 2 4 m transmission area approximately φ5 m Ceiling height 2 4 m 18 m 12 m ...

Страница 10: ...ape W 15 m D 12 m H 2 7 m transmission area approximately φ6 m 15 m 12 m Ceiling height 2 7 m School format horizontal W 18 m D 12 m H 2 7 m transmission area approximately φ6 m Ceiling height 2 7 m 18 m 12 m ...

Страница 11: ...10 School format vertical W 8 m D 12 m H 2 4 m transmission area approximately φ5 m 8 m Ceiling height 2 4 m 12 m ...

Страница 12: ...11 School format vertical W 13 m D 20 m H 2 7 m transmission area approximately φ6 m Ceiling height 2 7 m 20 m 13 m ...

Страница 13: ...12 School format vertical W 17 m D 16 26 m H 2 7 5 m transmission area approximately φ6 m Ceiling height minimum 2 7 m maximum 5 m 26 m 17 m 16 m 2 7 m 5 m ...

Страница 14: ...13 School format maximum 16 units W 20 m D 20 m H 2 7 m transmission area approximately φ6 m 20 m 20 m Ceiling height 2 7 m ...

Страница 15: ...es and power lines Refer to diagram below Measure B Use separate conduits for the lighting control wires and audio equipment wires Refer to diagram below Measure C Be sure to use D type type 3 ground connections for IRCU IRCUDAN lighting controls and audio controls Implement sufficient precautions because simultaneous interpretation systems and medical equipment may be affected by nearby lighting ...

Страница 16: ...RX terminal on the IRCU IRCUDAN A maximum of 16 IRAs can be installed by using IRDs Checkpoints Do not exceed 100 meters for the total length of cable connections When installing multiple IRAs use the same total cable lengths from the IRAs to the IRCU IRCUDAN We recommend a difference of less than 3 m Mounting holes Holes to mount IRD 1 2 3 4 IRA IRCU IRCUDAN Maximum of four units for each TX RX t...

Страница 17: ...evels may drop To synchronize the phases of the signals use the same total cable lengths from the IRAs to the IRCU IRCUDAN Length of cables from IRA to IRCU IRCUDAN L1 L2 N1 L3 M1 N1 Keep the differences in the L1 L2 N1 and L3 M1 N1 cables to within 3 m L1 L2 L2 L3 L3 L3 L3 M1 M1 N1 N1 IRA IRCU IRCUDAN IRD IRD ...

Страница 18: ...osses IRD loss 4 dB Attenuation per 100 m of coaxial cable 3C 2V 4 2 dB RG 59U 3 0 dB 5C 2V 2 7 dB RG 6U 2 3 dB 7C 2V 2 2 dB RG 11U 1 3 dB Values needed to calculate drop in voltage Operating current for each IRA 0 09 A Resistance of IRD 0 5 Ω Loop resistance per 100 m of coaxial cable at 20 C 3C 2V 9 14 Ω RG 59U 4 5 Ω 5C 2V 3 59 Ω RG 6U 3 0 Ω 7C 2V 2 07 Ω RG 11U 1 3 Ω The attenuation and loop res...

Страница 19: ...cable 1 Attenuation of coaxial cable 1 Attenuation of coaxial cable 2 Attenuation of coaxial cable 3 Coaxial cable 2 Coaxial cable 3 Conditions Total voltage drop 3 V Voltage drop of cable length 100 loop resistance per 100 m of cable current Current flowing in cable Number of IRAs connected to one TX RX terminal 0 09 A Total voltage drop Voltage drop 1 voltage drop 2 voltage drop 3 IRA IRD1 IRD2 ...

Страница 20: ...m IRCU IRCUDAN to IRAs 2 7 dB 50 m 100 m 1 35 dB Result is less than maximum allowable loss 15 dB 2 Calculating maximum allowable voltage drop of cables Voltage drop from IRCU IRCUDAN to IRAs 3 59 Ω 50 m 100 m 0 09 A 0 16 V Result is less than maximum allowable drop in voltage 3 V Use cable lengths that stay within the maximum allowable losses and maximum allowable voltage drops IRA IRCU IRCUDAN 5...

Страница 21: ...B The total attenuation from the cables and loss from the IRDs is 9 08 dB 0 27 dB 0 27 dB 0 54 dB 8 dB which is less than the maximum allowable loss 15 dB 2 Calculating maximum allowable drop in voltage Voltage drop from IRCU IRCUDAN to IRD1 3 59 Ω 10 m 100 m 0 09 A 4 0 129 V Voltage drop of IRD1 0 5 Ω 0 09 A 4 0 18 V Voltage drop between IRD1 and 2 3 59 Ω 10 m 100 m 0 09 A 2 0 064 V Voltage drop ...

Страница 22: ... Technica Corporation 2 46 1 Nishi naruse Machida Tokyo 194 8666 Japan www audio technica com 2018 Audio Technica Corporation Global Support Contact www at globalsupport com ver 1 2018 09 01 142900220 02 01 ...

Отзывы: