background image

Installation and Setup

AT-MX341b SmartMixer setup tips:

1.

Turn Master Threshold control to minimum threshold, immediately clockwise of the
“Manual” setting.

2.

Set all Priority  DIP switches to “down” position.

3.

Turn all four microphone Gain controls fully counter-clockwise.

4.

Connect the AC adapter to the mixer and plug in to outlet.

5.

Turn Power switch “on.” The mixer will perform a self-test and turn each microphone 
“on” and “off ” consecutively.

6.

Connect a microphone to Input 1 and turn the Gain 1 control to the “nine o’clock”
position. The channel 1 LED will light if the microphone is operational.

7.

Adjust the Gain 1 control for proper meter indication when speaking into microphone
(peaks at 0).

8.

Gradually increase the Master Threshold control until the Lockout LED flashes when
speaking at a normal level.

9.

Plug in up to three other microphones and adjust each respective Gain control for proper
meter indication. It should not be necessary to readjust the threshold level.

10. Priority can be assigned to one or more microphones by moving the appropriate DIP 

switch(es) to the “up” position. Any microphone(s) assigned in this manner cannot be 
locked out by any other microphone.

11. “Manual” mode can be selected at any time by simply turning the Master Threshold 

control fully counterclockwise. In this mode, the unit will behave like a conventional
four-channel microphone mixer (all automatic functions are bypassed).

12. The Master Level recessed control on the front panel may be adjusted with a small

screwdriver if necessary. This control is at the last stage in the mixer, and does not affect
microphone gain, threshold setting, or meter indication.

Priority Microphones and the Lockout Bus

Once the Master Threshold control has been properly adjusted, an audio signal appearing in 

any

channel causes the lockout control bus to activate and the Lockout LED indicator to light. The
Priority Pre-select switches then determine whether or not a particular mic is affected by lockouts
caused by other mics: a channel Priority switch in the “down” position 

will allow

lockout* of its mic; the same switch “up” 

will not allow

lockout of its mic.

*  Note that any mic which is described as “locked out” or “off ” is really just being attenuated by
between 6 dB and 20 dB from the level otherwise determined by its Gain control setting, 
sensitivity and placement.  See the “Daisy-chaining Mixers” section on page 10 for further details.

There are basically three “modes” of automatic operation:

Mode 1

... 

All

Priority Pre-select switches 

Up

The Lockout indicator will come on with any audio input, but no mic will be locked out…because
none are connected to the lockout bus. (This mode is often called 
“Free-for-all”…or sometimes “City Council”!)

6

Содержание AT-MX341b SmartMixer

Страница 1: ...Microphone Mixer Installation and Operation Lockout Manual Priority Pre select 1 2 3 4 20 10 6 3 0 3 6 Output Level Master Threshold Master Level Gain 1 Gain 2 Gain 3 Gain 4 Power AUTOMATIC MICROPHONE MIXER AT MX341b Selected Channel ...

Страница 2: ... 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation Caution for FCC You are cautioned that any changes or modifications not expressly approved in this manual could void your authority to operate this equipment Note This equipment has been tested and found to comply with the limits for a ...

Страница 3: ...o are carried between mixers by the link cable The result is that all microphones on a multi mixer system can be controlled by one micro phone connected to any mixer Since all of the mixers are independently powered there is no practical limit to the number of SmartMixers that can be daisy chained Features To custom tailor conferencing needs the mode of each microphone channel can be independently...

Страница 4: ...n assigns the respective channel priority over the other channels A priority channel can not be locked out by other channels Any combination of priority non priority selections is allowed 7 Master Level control Normal setting is fully clockwise full output If reducing the mixer s output is necessary carefully turn the control counter clockwise as needed with a small screwdriver Once set as desired...

Страница 5: ...tput Can be changed to mic level output via internal switch see page 7 XLRM type connector 5 Inputs Balanced microphone inputs for low impedance dynamic or condenser mics Can be changed to line level inputs via internal switches see page 7 XLRF type connectors Figure 2 Rear panel 5 Link In Link Out Output Input 3 Input 2 Input 1 12V AC 15 18V DC Control Voltage Out 1 GND 2 3 4 Input 4 Lockout Manu...

Страница 6: ...shold control fully counterclockwise In this mode the unit will behave like a conventional four channel microphone mixer all automatic functions are bypassed 12 The Master Level recessed control on the front panel may be adjusted with a small screwdriver if necessary This control is at the last stage in the mixer and does not affect microphone gain threshold setting or meter indication Priority Mi...

Страница 7: ...stances higher output microphones are used for close talking it may be necessary to reduce the preamplifier gain This can be done by changing switch settings inside the unit With the unit unplugged remove the two screws on each side of the unit and remove the top cover Locate the internal switches designated on the circuit board by S103 S203 S303 and S403 Figs 3 and 4 page 8 Changing the settings ...

Страница 8: ...B VR202 VR302 and VR402 control off attenuation for channels 2 3 and 4 respectively Figure 3 Internal view of mixer Figure 4 Detail of internal controls Don t Touch Rear Panel Output Level LED Meter The Output Level LED meter is factory set to indicate RMS output Should peak output indication be desired simply unplug the unit remove the top cover and change the setting of the switch designated on ...

Страница 9: ...Out goes high 4 VDC This signal can be used to light indicator lamps switch speaker zones on and off select video cameras etc The control voltage should not be connected directly to an inductive load such as a relay coil as dam age to the mixer may result Several interface circuit possibilities are shown in Figure 5 Figure 5 Control interface examples 9 ...

Страница 10: ... to the unit When using more than one SmartMixer in a system it may be advantageous to mount two mixers in a 1U rack space This can be accomplished using the two short rack ears and an optional joining plate Model AT8628 which allows two units to be con nected side by side in a single rack space Security Caps For permanent installations where microphone selections positions and acoustic conditions...

Страница 11: ... DC either polarity 300 mA Operating Temperature 32 to 104 0 to 40 C Dimensions 8 25 210 mm W x 9 38 238 mm D x 1 75 44 mm H including feet knobs and connectors Weight 3 1 lbs 1 4 kg Included Accessories AC adapter AT8325 1 0 Link Cable Optional Accessory AT8628 Double Rackmount Joining Plate In the interest of standards development A T U S offers full details on its test methods to other industry...