background image

   

9   

Limited Warranty

 

Audio Research Corporation products are covered 
by  a  3-Year  Limited  Warranty,  or  a  90-Day  Limited 
Warranty  (vacuum  tubes).    This  Limited  Warranty 
initiates from the date of purchase, and is limited to 
the  original  purchaser,  or  in  the  case  of 
demonstration  equipment,  limited  to  the  balance 
of warranty remaining after original shipment to the 
retailer or importer. 
In  the  United  States,  the  specific  terms,  conditions 
and remedies for fulfillment of this Limited Warranty 
are listed on the warranty card accompanying the 
product in its shipping carton, or may be obtained 
from  the  authorized  retailer  or  from  the  Audio 
Research  Customer  Service  Department.    Outside 
the  United  States,  the  authorized  importing  retailer 
or  distributor  has  accepted  the  responsibility  for 
warranty of Audio Research products sold by them.  
The specific terms and remedies for fulfillment of the 
Limited Warranty may vary from country to country.  
Warranty service should normally be obtained from 
the  importing  retailer  or  distributor  from  whom  the 
product was purchased. 
In the unlikely event that technical service beyond 
the  ability  of  the  importer  is  required,  Audio 
Research  will  fulfill  the  terms  and  conditions  of  the 
Limited  Warranty.    Such  product  must  be  returned 
at  the  purchaser's  expense  to  the  Audio  Research 
factory,  along  with  a  photocopy  of  the  dated 
purchase  receipt  for  the  product,  a  written 
description  of  the  problem(s)  encountered,  and 
any information necessary for return shipment.  The 
cost  of  return  shipment  is  the  responsibility  of  the 
purchaser. 
 
 
 

Specifications

 

FREQUENCY  RESPONSE:

  +0-3dB,  0.5Hz  to  200kHz  at 

rated output (Balanced, 200k ohms load). 

DISTORTION:

  Less than .01% at 2V RMS BAL output. 

GAIN:

  Main  output:  12dB  Balanced  output,  6dB  SE 

output.  Tape output: 0dB (Processor input: 0dB SE 
output). 

INPUT  IMPEDANCE:

  120K ohms Balanced, 60K ohms 

SE.  Inputs (7): CD, TUNER, VIDEO, PHONO, AUX 1, 
AUX 2, PROCESSOR.  (XLR and RCA connectors) 

OUTPUT IMPEDANCE:

  600 ohms Balanced, 300 ohms 

SE Main (2). 20K ohms minimum load and 2000pF 
maximum  capacitance.  Outputs  (3):  2  main,  1 
tape (XLR and RCA connectors). 

OUTPUT POLARITY:

  Non-inverting. 

MAXIMUM INPUT:

  20V RMS BAL, 10V RMS SE. 

RATED  OUTPUTS:

  2V RMS (1V RMS SE) into 200K ohm 

balanced  load  (maximum  balanced  output 
capability  is  30V  RMS  at  less  than  0.5%  THD  at 
1kHz). 

CROSSTALK:

  -80dB or better at 1kHz and 10 kHz. 

CONTROLS:

  Volume (104 steps), Select Input.  Push 

Buttons:  Power, Proc, BAL/SE, Mono, Invert, Mute. 

POWER  SUPPLIES:

    Electronically  regulated  low  and 

high  voltage  supplies.    Automatic  40  sec.  warm-
up/brown-out  mute.    Line  regulation  better  than 
.01%. 

NOISE:

  1.7uV RMS residual IHF weighted balanced 

equivalent  input  noise  with  volume  at  1  (109dB 
below 2V RMS output.) 

TUBE  COMPLEMENT:

    (4)-6H30P  dual  triodes,  plus  (1 

each) 6550C and 6H30P in power supply. 

POWER  REQUIREMENTS:

    100-135VAC  60Hz  (200-

270VAC 50/60Hz) 130 watts.  Standby: 2 watts. 

DIMENSIONS:   

19"  (48  cm)  W  x  7"  (17.8  cm)  H 

(standard  panel)  x  15.5"  (39.4  cm)  D.    Handles 
extend 1.5" (3.8 cm) forward of the front panel. 

WEIGHT:

    30.4  lbs.  (13.9  kg)  Net;  41.6  lbs.  (19  kg) 

Shipping. 

 

Specifications subject to change without notice. 
 
©2011 Audio Research Corporation. 

 
 

Содержание Reference 5 SE

Страница 1: ...Owner s Manual Reference 5 SE Stereo Preamplifier...

Страница 2: ...2...

Страница 3: ...reface 5 Warnings 5 Packaging 5 Installation of Vacuum Tubes 5 Description of Controls 6 7 Connections 7 Installation Instructions 7 Operating Procedure 7 Troubleshooting 8 Servicing 8 Cleaning 8 Disp...

Страница 4: ...4...

Страница 5: ...delay and added expense whenever shipment of this unit is required DO NOT ATTEMPT TO OPERATE THIS EQUIPMENT BEFORE INSTALLING THE NUMBERED VACUUM TUBES IN THEIR RESPECTIVE SOCKETS Installation of Vac...

Страница 6: ...restored Note that automatic muting is only designed to protect against power line interruptions or severe voltage drop It will not mute in the event of subsonic transmissions from a faulty input sou...

Страница 7: ...IN OUT REMOTE START JACKS The 12V DC input output jacks provide the ability to remotely turn on and off the preamp and other linked components such as power amplifiers having similar capabilities Ins...

Страница 8: ...able from Audio Research Note that tube numbers V1 V2 etc match printed numbers next to tube sockets on circuit board Should service be necessary please contact your Audio Research dealer or Audio Res...

Страница 9: ...nd any information necessary for return shipment The cost of return shipment is the responsibility of the purchaser Specifications FREQUENCY RESPONSE 0 3dB 0 5Hz to 200kHz at rated output Balanced 200...

Отзывы: