The rotary control on the left adjusts Volume (output level)
up or down for both R and L channels. Volume control is
also  selectable  via  Vol  DN  and  Vol  UP  buttons  on  the 
remote  control.  Volume  adjustment  is  indicated  in  the 
display window by volume LEDs numbered 1–20.

Do  not  turn  volume  up  beyond  normal  listening  levels
when  “mute”  is  engaged  to  avoid  unexpected  or  possibly
damaging  sound  levels.  Reduce  volume  level  whenever
changing input sources, even when muted.

The  rotary  control  on  the  right  selects  any  of  five  input
sources connected to the preamp: CD, Tuner, BAL 1, BAL 2
and  Aux.  Each  of  these  sources  may  also  be  selected  via 
direct  access  buttons  on  the  remote  control.  The  selected
source is indicated in the display window.

F ront Panel and LS17R Remote 

C o n t rol Buttons

POWER ON/OFF: 

Supplies power from A.C. wall outlet to

preamp;  indicated  by  active  display  window.  Function 
also on remote control.

For  approximately  50  seconds  after  start  up,  “Mute” 
LED flashes until the automatic muting cycle is completed.
This also occurs in the event of power interruption. Upon
completing  the  cycle,  “Mute”  will  cease  flashing.  The  pre-
amp will remain muted until normal operation is selected
by pressing the “Mute” button.

MUTE

: When activated, electrically mutes all output of the

preamplifier;  indicated  by  lit  “Mute”  LED.  This  control
should  be  activated  before  switching  inputs,  changing 
connections  or  shutting  down  your  audio  system  to  help
protect your amplifier and speakers from unexpected signal
pulses.  When  deactivated,  “Mute”  LED  shuts  off  in  the 
display  window  allowing  normal  operation.  Function  also
on remote control. 

The LS17 also has automatic muting to help protect system
components  during  A.C.  power  interruptions  or  low  line
voltage.  When  sensing  these  conditions,  the  preamp 
automatically  goes  into  “Mute”  and  disables  all  outputs.
The 50-second warm-up timer will restart and “Mute” LED
will flash in the display window when normal power con-
ditions have been restored.

Note  that  automatic  muting  is  only  designed  to  protect
against  power  line  interruptions  or  severe  voltage  drop. 
It  will  not  mute  in  the  event  of  subsonic  transmissions
from  a  faulty  input  source,  amplifier  failure  or  speaker 
malfunction. 

PROCESSOR (PROC):

May be selected by button on front

panel  or  on  remote  control.  Selects  external  A-V  (home 

theater) processor as input source and controller of volume
level for R and L channels. LS17 provides Unity Gain when
this input is selected.

When  engaged,  “PROC”  LED  will  be  lit  and  the  volume 
control is not adjustable because gain is fixed. The preamp
will also mute the input after “PROC” is engaged.

WARNING:  Before  unmuting  the  “PROC”  input,  be  sure
to turn the volume down on the home-theater processor.
Never connect a source with a fixed level output (DVD
player,  tuner,  CD,  etc.)  to  the  PROC  input  or  the 
amplifier(s) and speaker system could be damaged when
the LS17 is unmuted.

VOLUME  UP/ D O W N :

Increases/decreases  overall  volume

level of both channels equally for whichever input has been
selected.  Caution:  do  not  turn  up  volume  beyond  normal
listening levels when “Mute” is engaged to avoid unexpect-
ed or possibly damaging sound levels. It is a good idea to
reduce  volume  whenever  changing  program  sources,  even
when muted. Function available on remote control buttons
and front panel rotary control on left. .

MONITOR:

Selecting Monitor (“Monitor” LED lights) routes

Monitor input signal to the Main outputs.

The  input  selector  indicates  what  is  routed  to  the  Record
out.  To  exit  the  monitor  position  and  return  to  program
source controlled by input selector (CD, Tuner, Aux, etc.),
press  monitor  switch  again.  Monitor  function  also  on 
remote control.

Connections

INPUT  CONNECTORS:

The  LS17  provides  two  pairs  of

B AL input connectors (BAL 1 and BAL 2) and five sets of SE
input connectors (Aux, Tuner, CD, Processor and Monitor).

OUTPUT CONNECTORS:

Two pairs of BAL and one pair of

SE main outputs are provided.

RECORD OUTPUT:

The SE Record outputs should be con-

nected  to  your  recorder's  “Record”  or  “Line”  inputs.  These
outputs  provide  a  fixed-level  two-channel  signal 
( R , L )  to  your  recorder  from  whichever  input  is  selected.
The non-variable output level will be the same as the out-
put of the selected source.

It is possible to dub or copy from one recorder to another
by  connecting  the  output  of  the  source  recorder  to  an 
unused  set  of  stereo  inputs  (Aux  1,  Aux  2).  The  signal 
will  then  be  routed  to  the  Record  Out  connectors  when
that input source is selected.

Model LS17

2

Содержание LS17

Страница 1: ...3900 ANNAPOLIS LANE NORTH PLYMOUTH MINNESOTA 55447 5447 PHONE 763 577 9700 FAX 763 577 0323 Model LS17 STEREO PREAMPLIFIER Owner s Manual...

Страница 2: ...1 Installation of Vacuum Tubes 1 Description of Controls 1 2 Connections 2 3 Installation Instructions 3 Operating Procedure 3 Tape Recording Procedure 3 Troubleshooting 3 Servicing 3 Cleaning 4 Disp...

Страница 3: ...UNIT MUST BE OPERATED IN A HORIZONTAL POSITION DO NOT OPERATE WITH COVERS REMOVED UNIT CONTAINS VOLTAGES WHICH MAY BE HAZARDOUS CAUTION FOR PROTECTION AGAINST FIRE HAZARD REPLACE ONLY WITH SAME RATIN...

Страница 4: ...ume down Visible numerically 1 20 on LED display Input for external A V processor Provides unity gain disabling volume controls Mutes output of LS17 Routes the monitor input signal to the main outputs...

Страница 5: ...materials help pro tect your investment from unnecessary damage delay and added expense whenever shipment of this unit is required Installation of Vacuum Tubes Note This unit has been shipped with the...

Страница 6: ...transmissions from a faulty input source amplifier failure or speaker malfunction PROCESSOR PROC May be selected by button on front panel or on remote control Selects external A V home theater process...

Страница 7: ...t This routes the selected program to the Record output Note If the Processor input is activated by selecting the Processor switch position all other inputs will be deacti vated When recording from th...

Страница 8: ...uum tubes This Limited Warranty initiates from the date of purchase and is limited to the original purchaser or in the case of demonstration equipment limited to the balance of warranty remaining afte...

Страница 9: ...less than 0 5 THD at 1kHz CONTROLS Rotary volume selector 104 steps 20 LED indicators and rotary input selector Push buttons Power Monitor Proc Mute Also remote buttons Bal 1 Bal 2 Aux Tuner CD POWER...