background image

   

8   

12V  IN/OUT  REMOTE  START  JACKS:

    The  +12V  DC 

input/output  jacks  provide  the  ability  to  remotely 
turn  on  and  off  the  preamp  and  other  linked 
components such as power amplifiers having similar 
capabilities. 
 

Installation Instructions

 

While  the  LS17  SE  does  not  dissipate  an  unusual 
amount  of  heat,  it  is  important  that  it  be  provided 
with  reasonable  airflow  to  assure  long,  trouble-free 
operation.    In  addition,  the  following  installation 
guidelines  will  help  insure  maximum  sonic 
performance as well as reliable service: 
1.

 

Operate  unit  in  upright  and  horizontal  position, 
prefer-ably on solid, non-metal shelving. 

2.

 

Do  not  stack  the  preamp  on  top  of  a  power 
amplifier: not only could this cause overheating, 
but  hum  may  be  introduced  into  the  preamp 
from  the  proximity  of  the  amplifier's  power 
transformer.  Do not stack components or other 
objects directly on top of the LS17 SE. 

3.

 

Do not place or operate your preamp on a soft 
or  irregular  surface  such  as  a  rug.    This  will 
prevent proper ventilation. 

4.

 

Do  not  operate  your  preamp  without  the  top 
and bottom covers installed.  These are required 
both  for  safety  as  well  as  shielding  from 
interference  (except  in  service  operations  by 
qualified personnel). 

 

Operating Procedure

 

Start Up:

 

1.

 

Secure  all  rear-panel  connections  between 
LS17 SE, power amplifier(s) and input sources. 

2.

 

Plug  three-prong  power  cord  from  rear  of 
chassis  into  grounded  A.C.  wall  outlet.    The 
Power  switch  defaults  to’off’  when  the  unit  is 
plugged into a power receptacle. 

3.

 

Press  power  switch  (either  remote  or  front 
panel).    ‘Mute’  LED  will  flash  in  the  display 
window  for  approximately50  seconds,  then 
cease  flashing  and  remain  on.  Press’Mute’  to 
initiate operation. 

4.

 

Select input source, then BAL or SE as necessary. 

 

Shut Down:

 

1.

 

Activate ‘Mute’ function. 

2.

 

Set Volume level to minimum. 

3.

 

Turn off power amplifier(s). 

4.

 

Press Power switch to ‘off’. 

5.

 

Turn off input sources. 

 

Tape Recording Procedure

 

When  using  the  LS17  SE  as  a  control  center  for 
recording, the program source to be recorded must 
be  connected  to  one  of  the  five  inputs  controlled 

by  the  Input  selector  switch  or  to  the  Processor 
input.    This  routes  the  selected  program  to  the 
Record output. 
Note:    If  the  Processor  input  is  activated  by 
selecting  the  ‘Processor’  switch  position,  all  other 
inputs  will  be  deactivated.    When  recording  from 
the Processor input to the Record out of the LS17 SE, 
the level of the recording will be dependent on the 
level setting of the processor. 
If  you  own  a  three-head  tape  deck,  and  wish  to 
monitor  the  actual  tape  while  making  a  recording 
(for  a  true  ‘A-B’  comparison  of  signals  before  and 
after recording), connect the tape deck output to 
the Monitor input. 
It  is  also  possible  to  dub  from  one  tape  deck  to 
another.  Simply connect the output from one tape 
deck  to  an  un-used  set  of  inputs  controlled  by  the 
Input  selector  (Tuner,  Phono,  CD,  etc.)  on  the  LS17 
SE.    This  signal  will  then  be  routed  to  the  second 
tape  deck  through  the  Record  output  when  the 
appropriate input is selected on the Input selector. 
 

Troubleshooting

 

It  is  possible  for  a  static  discharge  to  temporarily 
disable  the  microprocessor  that  allows  the  controls 
to function.  If this should occur, depress the ‘Mute’ 
button,  then  turn  off  the  preamp  and  unplug  the 
preamp  from  the  A.C.  receptacle  for  60  seconds.  
Reconnect  the  A.C.  plug  and  turn  the  preamp 
back  on,  along  with  other  components.    The 
controls  should  resume  normal  operation.    If  the 
problem  persists,  contact  your  dealer  or  Audio 
Research Customer Service at 763-577-9700. 
 

Servicing

 

Because  of  its  careful  design  and  exacting 
standards  of  manufacture,  your  LS17  SE  should 
require  no  routine  maintenance.    The  remote 
control's  batteries  (AAA)  should  be  replaced  once 
a year. 

CAUTION:

    Your  LS17  SE  contains  sufficient  levels  of 

voltage  and  current  to  be  lethal.    Do  not  tamper 
with a component or part inside the unit.  Refer any 
needed service to your authorized Audio Research 
dealer or other qualified technician. 
The  vacuum  tubes  inside  your  LS17  SE  are  quality 
6H30 dual triode tubes and with normal use should 
not  need  to  be  changed  for  approximately  4,000 
hours  of  use.    Replacement  tubes  should  be  of 
equivalent  quality  and  are  available  from  Audio 
Research.    Note  that  tube  numbers  (V1  and  V2) 
match  printed  numbers  next  to  tube  sockets  on 
circuit board. 
Should  service  be  necessary,  please  contact  your 
Audio  Research  dealer,  or  Audio  Research 
Customer Service at 763 577-9700. 

Содержание LS17 SE

Страница 1: ...Owner s Manual LS17 SE Stereo Preamplifier...

Страница 2: ...2...

Страница 3: ...ce 6 Warnings 6 Packaging 6 Installation of Vacuum Tubes 6 Description of Controls 7 Connections 7 Installation Instructions 7 8 Operating Procedure 8 Tape Recording Procedure 8 Troubleshooting 8 Serv...

Страница 4: ...4...

Страница 5: ...All LS17 SE functions are available on the LS17R hand held remote controller All functions are indicated on the front panel as they are selected See Description of Controls in this manual for more inf...

Страница 6: ...ent if repackaged in cartoning other than that designed for it The original packaging materials help protect your investment from unnecessary damage delay and added expense whenever shipment of this u...

Страница 7: ...rop It will not mute in the event of subsonic transmissions from a faulty input source amplifier failure or speaker malfunction PROCESSOR PROC May be selected by button on front panel or on remote con...

Страница 8: ...sor input This routes the selected program to the Record output Note If the Processor input is activated by selecting the Processor switch position all other inputs will be deactivated When recording...

Страница 9: ...nty vacuum tubes This Limited Warranty initiates from the date of purchase and is limited to the original purchaser or in the case of demonstration equipment limited to the balance of warranty remaini...

Страница 10: ...VRMS at less than 0 5 THD at 1kHz CONTROLS Rotary volume selector 104 steps 20 LED indicators and rotary input selector Push buttons Power Monitor Proc Mute Also remote buttons Bal 1 Bal 2 Aux Tuner C...

Отзывы: