background image

11

Operation

Start-Up

•  Secure all rear-panel connections between 

PH9, preamplifier, and input sources.

•  Plug three-prong power cord from 

rear of chassis into grounded A.C. wall 

outlet.  The Power switch defaults to ’off’ 

when the unit is plugged into a power 

receptacle.

•  Press power switch (either on the remote 

or front panel). The phono preamplifier 

will begin the warm-up sequence, which 

lasts approximately two minutes, during 

which ‘MUTE’ will flash on the display. 

After the warm-up sequence is complete, 

the unit will be muted. Depress the 

front panel ‘MUTE’ button or the Mute 

button on the remote to initiate normal 

operation. You may depress the Mute 

button prior to the unit completing the 

warm-up cycle; ‘MUTE OFF’ will flash on 

the display until the warm-up cycle is 

complete.

•  Select input source and adjust the volume 

on your preamplifier as necessary.

Note

The two minute warm-up time is required 

for the circuit to come to an appropriate 

operating temperature, as well as for the 

power supply to stabilize. This is a normal 

function of the PH9.

Shut-Down

•  Activate ‘MUTE’ function.

•  Turn off power amplifier(s).

•  Turn off preamplifier.

•  Press Power switch to ‘off’ on PH9.

•  Turn off input sources.

Note

The PH9 should be turned on before 

the preamplifier or amplifier in your 

system. If the PH9 is turned on after 

the preamplifier and amplifier, it will 

amplify any extraneous turn-on noises 

the PH9 might generate, which could 

potentially damage the loudspeakers. 

Good operating practice dictates that 

the amplifier should be turned on last, 

and turned off first in an audio system.

Break-in

All quality stereo equipment benefits from 

a break-in period; during this time, the 

various components, wiring and solder 

connections change as electrical signals 

pass through them. While your PH9 

will sound fantastic out of the box, it 

will only improve with continued use.

Содержание HIGH DEFINITION PH9

Страница 1: ...PH9...

Страница 2: ......

Страница 3: ...tening however please take a few minutes to read through this guide for useful information concerning the operation of your new phono preamplifier Once installed please allow an appropriate break in p...

Страница 4: ...7 8 9 9 9 9 9 Operation Front Panel Controls and Display Start Up Shut Down Break in Front Panel Controls Remote Only Functions Settings Menu System Settings Menu Tree Settings Menu Auto Shutdown Car...

Страница 5: ...n For continued protection against fire hazard replace the fuse only with the same type and rating as specified at the fuse holder see page 19 for fuse information This unit is RoHS compliant The PH9...

Страница 6: ...cording to the following instructions Installation Remove all screws fastening the top cover Carefully remove each vacuum tube from its protective foam and match its location V number written on the b...

Страница 7: ...hat adequate airflow above and to each side of the unit is provided Audio Research recommends a minimum of 6 8 inches 15 20 cm of clearance above the PH9 to maintain proper ambient operating temperatu...

Страница 8: ...8 Connections A C Mains connector Fuse Holder RS 232 connector IR Input Phono Input Main Outputs Back Panel Connections Ground Connection...

Страница 9: ...front of the PH9 for On Off control of the preamplifier or the IR input RS232 or remote control RS 232 Input The RS 232 input allows connection of a control or automation system IR Input The IR input...

Страница 10: ...10 Operation Front Panel Controls and Display Vacuum Fluorescent Display Power On Off Menu Option used with Menu Mono Mute Enter used with Menu...

Страница 11: ...preamplifier as necessary Note The two minute warm up time is required for the circuit to come to an appropriate operating temperature as well as for the power supply to stabilize This is a normal fun...

Страница 12: ...er details about using the setup menu Option The Option button is used in conjunction with the Menu button to select the various options in the settings menu Enter The Enter button is used in conjunct...

Страница 13: ...urs By this time we recommend replacing them to maintain the best performance of your preamplifier Display Brightness Adjustment The front panel display has six brightness settings as well as the abil...

Страница 14: ...14 Operation System Settings Menu Tree...

Страница 15: ...for examples of the front panel display The MENU OPTION and ENTER buttons found on the front panel and remote are used to make changes to the menu settings Note that the MENU button can also be used t...

Страница 16: ...e load setting can also be changed directly from the remote control using the number buttons at the top Operation Tube Hours The tube hours display shows the accumulated time the PH9 has been powered...

Страница 17: ...center to indicate the unit is powered on To change the display brightness press the MENU button until DISPLAY BRIGHTNESS appears Press the OPTION button Continue to press the OPTION button to change...

Страница 18: ...omponent or part inside the unit Even with the power turned off a charge remains in the energy storage capacitors for hours or even days Cleaning To maintain the new appearance of this preamplifier oc...

Страница 19: ...19...

Страница 20: ...the United States the authorized importing retailer or distributor has accepted the responsibility for warranty of Audio Research products sold by them The specific terms and remedies for fulfillment...

Страница 21: ...m load maximum balanced output capability is 0 46V RMS at less than 0 5 THD at 1kHz Controls 6 Push Buttons Power Menu Option Enter Input Mute Power Supplies Electronically regulated low and high volt...

Страница 22: ...notice 2016 Audio Research Corporation Reproduction of this document in part or whole is expressly forbidden without written consent from Audio Research Corporation 3900 Annapolis Lane North Plymouth...

Отзывы: