LCD-9151-201-x Installation Manual
Document # 540334, Rev IR1, 10/2006
Page 6 of 20
3.1.3 If the adjustment switch (SP-LCD6) is to be mounted in the aircraft,
the following should be considered; the pigtail is 24 inches
(60.96 cm) in length ±1 inch (2.54 cm) and has 6-32 x 0.75 inch
mounting studs. Refer to Sections 5.0 and 6.2 for the adjustment
switch characteristics.
3.1.4 An internal fan exhausts heat from the unit. Proper ventilation must
be allowed for when specifying the installation location. The
closeout area of the monitor shall have a clearance of 2 inches
(5.08 cm) minimum for the air inlet and exit areas. The closeout
area of the monitor case shall not block the air inlet or exhaust
openings of the monitor case. The fan will only run when the unit is
turned on.
3.1.5 Mounting provisions are provided via right-angle flanges attached
to each side of the monitor case. These flanges provide the user
with the means of mounting the unit. Refer to Section 6.0,
Reference Drawings, for mounting hole diameters and
configuration.
3.1.6 The monitor should be located as close to the source equipment as
possible in order to reduce the possibility of noise introduced into
the video. Refer to Section 6.0 for unit dimensions.
3.1.7 The LCD-9151-201-x is configured using the external menu
selection switch, SP-LCD6. The switch utilizes a D-Subminiature
connector. This connector mates with the D-Subminiature
connector on the LCD-9151-201-1 model monitor.
3.1.8 A 3/8
″
long grounding lug is included as part of the housing. See
Section 6.0 for details.
3.1.9 The maximum length of the connection to PC Graphic (VGA) input
is 15 feet.