9
LINE INPUT---BALANCED---SUBSONIC---BASS EQ---REMOTE---LOW PASS---PHASE---LEVEL---POWER---LINE OUT
PROTECT
LCH
RCH
L
R
15Hz 35Hz 0dB 18db 35Hz 250Hz 0 180 9V 0.2V
INPUT
Amplifier- Functions and Controls
BX 750 / BX 1000D MKII / BX 1500D MKII
LOW PASS/SUB SONIC
LOW PASS -
The built in low pass filter is fully variable from 35Hz to 250Hz,
SUB SONIC -
Eliminates the lowest frequencies to protect the speakers from damages. These
low frequencies can cause damages. The frequency is adjustable from 15 Hz to 35 Hz
Protect - LED
Red LEDis illuminated:
a) Overheated
b) Speaker wires shorted
c) Overload (Impedance, less Power)
d) Amplifier is damaged
Should the amplifier go into proteciont mode, simply disconnect
all RCA and speaker leads, while k12 volt, power ground
and remote leads connected. Now turn the amplifier back on, and
if the PROTECT-LED lights, the amplifier has an internal fault.
If not, plug the RCA cables back, and reset the amplifier. If it goes
into protection mode now, the fault lies in the input, either with
bad cables or source unit.
If the amplifier seems fine with RCA cables plugged in, connect
the speakers, one at a time, and if one of the speakers or its
wiring is faulty, it will activate the diagnostic
system.
Line
I
nput -
Full range
line input connect with
the head unit
Remote -
Connection for remote
control.Allows you to adjust the
subwoofer from your seat
Bass EQ -
Allows you
to adjust the bass boost
from 0dB up to 18dB at
45 Hz
Level -
This allows you to
match the input sensitivity
from 9 Volts to 0,2 Volts
Power - LED
Green LED is illuminated
amplifier is on
Line Out -
Full range
output that allows you to
use additional amplifiers
Phase -
Phase from 0° to
180°.
This allows you to
match the
Balanced Input -
Connect Head unit and
amplifier with a line driver
cable.